995 resultados para Multivariate Monitoring
Resumo:
The pumping processes requiring wide range of flow are often equipped with parallelconnected centrifugal pumps. In parallel pumping systems, the use of variable speed control allows that the required output for the process can be delivered with a varying number of operated pump units and selected rotational speed references. However, the optimization of the parallel-connected rotational speed controlled pump units often requires adaptive modelling of both parallel pump characteristics and the surrounding system in varying operation conditions. The available information required for the system modelling in typical parallel pumping applications such as waste water treatment and various cooling and water delivery pumping tasks can be limited, and the lack of real-time operation point monitoring often sets limits for accurate energy efficiency optimization. Hence, alternatives for easily implementable control strategies which can be adopted with minimum system data are necessary. This doctoral thesis concentrates on the methods that allow the energy efficient use of variable speed controlled parallel pumps in system scenarios in which the parallel pump units consist of a centrifugal pump, an electric motor, and a frequency converter. Firstly, the suitable operation conditions for variable speed controlled parallel pumps are studied. Secondly, methods for determining the output of each parallel pump unit using characteristic curve-based operation point estimation with frequency converter are discussed. Thirdly, the implementation of the control strategy based on real-time pump operation point estimation and sub-optimization of each parallel pump unit is studied. The findings of the thesis support the idea that the energy efficiency of the pumping can be increased without the installation of new, more efficient components in the systems by simply adopting suitable control strategies. An easily implementable and adaptive control strategy for variable speed controlled parallel pumping systems can be created by utilizing the pump operation point estimation available in modern frequency converters. Hence, additional real-time flow metering, start-up measurements, and detailed system model are unnecessary, and the pumping task can be fulfilled by determining a speed reference for each parallel-pump unit which suggests the energy efficient operation of the pumping system.
Resumo:
Remote monitoring of a power boiler allows the supplying company to make sure that equipment is used as supposed to and gives a good chance for process optimization. This improves co-operation between the supplier and the customer and creates an aura of trust that helps securing future contracts. Remote monitoring is already in use with recovery boilers but the goal is to expand especially to biomass-fired BFB-boilers. To make remote monitoring possible, data has to be measured reliably on site and the link between the power plant and supplying company’s server has to work reliably. Data can be gathered either with the supplier’s sensors or with measurements originally installed in the power plant if the plant in question is not originally built by the supplying company. Main goal in remote monitoring is process optimization and avoiding unnecessary accidents. This can be achieved for instance by following the efficiency curves and fouling in different parts of the process and comparing them to past values. The final amount of calculations depends on the amount of data gathered. Sudden changes in efficiency or fouling require further notice and in such a case it’s important that dialogue toward the power plant in question also works.
Resumo:
The aim of this work was the identification of geographic zones suitable for the production of honeys in which pollen grains of Escallonia pulverulenta (Ruiz & Pav.) Pers. (Saxifragaceae) can be detected. The analysis of botanical origin of 240 honey samples produced between La Serena and Puerto Mont (the IV and X Administrative Regions of Chile), allowed the detection of pollen grains of E. pulverulenta in 46 Chilean honeys. The geographic distribution of the honeys studied is presented together with their affinities, through factor analysis and frequency tables. The study was based on the presence of E. pulverulenta pollen. Escallonia pulverulenta pollen percentages oscillated between 0.24% and 78.5%. Seventeen of the studied samples were designated as unifloral - i.e. samples showing more than 45% pollen of a determined plant species. Two of these corresponded to E. pulverulenta (corontillo, madroño or barraco) honeys. The remaining unifloral honeys correspond to 8 samples of Lotus uliginosus Schkuhr (birdsfoot trefoil), 2 samples of Aristotelia chilensis (Molina) Stuntz (maqui) and 1 sample of Escallonia rubra (Ruiz & Pav.) Pers. (siete camisas), Eucryphia cordifolia Cav. (ulmo or muemo), Weinmannia trichosperma Cav. (tineo), Rubus ulmifolius Schott (blackberry) and Brassica rapa L. (turnip). Honeys with different percentages of E. pulverulenta pollen - statistically analyzed through correspondence analysis - could be associated and assigned to one of three geographic types, defined on the basis of this analysis. The geographical type areas defined were the Northern Mediterranean Zone (samples from the IV Region), Central Mediterranean Zone (samples from the V to the VIII regions including two samples of unifloral Escallonia pulverulenta honey), and Southern Mediterranean Zone (samples from the IX Region).
Resumo:
Genetic distances among cacao cultivars were calculated through multivariate analysis, using the D2 statistic, to examine racial group classification and to assess heterotic hybrids. A 5 x 5 complete diallel was evaluated. Over a five-year period (1986-1990), five cultivars of the S1 generation, pertaining to the Lower Amazon Forastero and Trinitario racial groups and 20 crosses between the corresponding S0 parents were analyzed, based upon five yield components - number of healthy and collected fruits per plant (NHFP and NCFP), wet seed weight per plant and per fruit (WSWP and WSWF), and percentage of diseased fruits per plant (PDFP). The diversity analysis suggested a close relationship between the Trinitario and Lower Amazon Forastero groups. A correlation coefficient (r) was calculated to determine the association between genetic diversity and heterosis. Genetic distance of parents by D2 was found to be linearly related to average performance of hybrids for WSWP and WSWF (r = 0.68, P < 0.05 and r = 0.76, P < 0.05, respectively). The heterotic performance for the same components was also correlated with D2, both with r = 0.66 (P < 0.05). A relationship between genetic divergence and combining ability effects was suggested because the most divergent cultivar exhibited a high general combining ability, generating the best performing hybrids. Results indicated that genetic diversity estimates can be useful in selecting parents for crosses and in assessing relationships among cacao racial groups.