995 resultados para Lead alloys.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of the Ghanaian government’s objective of structural transformation with an emphasis on manufacturing, this paper provides a case study of economic transformation in Ghana, exploring patterns of growth, sector transformation, and agglomeration. We document and examine why, despite impressive growth and poverty reduction figures, Ghana’s economy has exhibited less transformation than might be expected for a country that has recently achieved middle-income status. Ghana’s reduced share of agriculture in the economy, unlike many successfully transformed countries in Asia and Latin America, has been filled by services, while manufacturing has stagnated and even declined. Likely causes include weak transformation of the agricultural sector and therefore little development of agro-processing, the emergence of “consumption cities” and consumption-driven growth, upward pressure on the exchange rate, weak production linkages, and a poor environment for private-sector-led manufacturing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study aimed to compare the cytotoxicity of base-metal dental alloys and to evaluate if the casting method could influence their cytotoxicity. Methods: Disks of base-metal dental alloys were cast by two methods: plasma, under argon atmosphere, injected by vacuum-pressure; and oxygen-gas flame, injected by centrifugation, except Ti-6Al-4V and commercially pure titanium (cpTi), cast only by plasma. SCC9 cells were cultured in culture media D-MEM/Ham`s F12 supplemented, at 37 degrees C in a humidified atmosphere of 5% carbon dioxide and 95% air, on the previously prepared disks. At subconfluence in wells without disks (control), cell number and viability were evaluated. Results: In plasma method, cpTi and Ti-6Al-4V were similar to control and presented higher number of cells than all other alloys, followed by Ni-Cr. In oxygen-gas name method, all alloys presented fewer cells than control. Ni-Cr presented more cells than any other alloy, followed by Co-Cr-Mo-W which presented more cells than Ni-Cr-Ti, Co-Cr-Mo, and Ni-Cr-Be. There were no significant differences between casting methods related to cell number. Cell viability was not affected by either chemical composition or casting methods. Conclusion: cpTi and Ti-6Al-4V were not cytotoxic while Ni-Cr-Be was the most cytotoxic among tested alloys. The casting method did not affect cytotoxicity of the alloys. (c) 2007 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 mu m [SD: 91.48] to 39.90 mu m [SD: 27.13]) and cpTi (118.56 mu m [51.35] to 27.87 mu m [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the relationship between iron deficiency/iron deficiency anaemia, assessed by several parameters, and blood lead concentration in children. This cross-sectional study involved 384 Brazilian children, aged 2-11 years, who lived near a lead-manipulating industry. Complete blood counts were obtained by an automated cell counter. Serum iron, total iron binding capacity (TIBC) and ferritin were determined respectively, by colorimetric, turbidimetric methods and chemiluminescence. Blood lead was measured by atomic absorption spectrophotometry. The impact of several parameters for assessment of iron status (haemoglobin, serum iron, TIBC, transferrin saturation, ferritin, red cell indices and red cell distribution width) and variables (gender, age, mother`s education, income, body mass index, iron intake, and distance from home to lead-manipulating industry) on blood lead concentration was determined by multiple linear regression. There were significant negative associations between blood lead and the distance from home to the lead-manipulating industry (P < 0.001), Hb (P = 0.019), and ferritin (P=0.023) (R(2)=0.14). Based on these results, further epidemiological studies are necessary to investigate the impact of interventions like iron supplementation or fortification, as an attempt to decrease blood lead in children. (C) 2011 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents the in-vivo evaluation of Ti-13Nb-13Zr alloy implants obtained by the hydride route via powder metallurgy. The cylindrical implants were processed at different sintering and holding times. The implants` were characterized for density, microstructure (SEM), crystalline phases (XRD), and bulk (EDS) and surface composition (XPS). The implants were then sterilized and surgically placed in the central region of the rabbit`s tibiae. Two double fluorescent markers were applied at 2 and 3 weeks, and 6 and 7 weeks after implantation. After an 8-week healing period, the implants were retrieved, non-decalcified section processed, and evaluated by electron, UV light (fluorescent labeling), and light microscopy (toluidine blue). BSE-SEM showed close contact between bone and implants. Fluorescent labeling assessment showed high bone activity levels at regions close to the implant surface. Toluidine blue staining revealed regions comprising osteoblasts at regions of newly forming/formed bone close to the implant surface. The results obtained in this study support biocompatible and osseoconductive properties of Ti-13Nb-13Zr processed through the hydride powder route. (c) 2007 Published by Elsevier B.V.