1000 resultados para Class Overriding


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we define the composite function for a special class of generalized mappings and we study the invertibility for a certain class of generalized functions with real values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate whether menstrual irregularity in morbidly obese women is indicative of metabolic dysfunction.Patients and Methods. Fifty-seven women with morbid obesity were evaluated. They were divided into two groups: one comprising women without menstrual dysfunctions or hirsutism (Group 1), and another obese women showing menstrual dysfunction with or without hirsutism (Group 2). The following were evaluated: age, colour, childbirth, marital status, profession, socio-economic level, education, age at menarche, body weight, height, body mass index, presence of hirsutism (Ferriman Gallwey Index), abdominal circumference, hip circumference, waist-to-hip ratio, menstrual cycle, blood pressure, presence of acanthosis nigricans, insulin resistance (IR), fasting glycaemia, total cholesterol, HDL-C, LDL-C, triglycerides, thyroid-stimulating hormone, free T4, luteinising hormone (LH), follicle-stimulating hormone, prolactin, total testosterone, dehydroepiandrosterone sulfate, insulin and the Homeostasis Model Assessment (HOMA test).Results. Clinical and epidemiological aspects did not present statistical differences. Clinical and laboratory parameters did not show statistically significant alterations; however, HOMA test values for Group 2 were significantly higher than those for Group 1.Conclusions. The presence of IR in class III obese women can cause menstrual dysfunctions such as amenorrhoea or oligomenorrhoea even in the absence of hyperandrogenism, suggesting that IR plays an important role in the ovarian mechanisms involved in the menstrual cycle control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to detect several new HLA-A class I alleles that have been described since 1998, the original PCR-RFLP method developed to identify the 78 alleles recognized at that time at high resolution level was adapted by us for low and medium resolution levels using a nested PCR-RFLP approach. The results obtained from blood samples of 23 subjects using both the PCR-RFLP method and a commercial kit (MicroSSP1A®, One Lambda Inc.) showed an agreement higher than 95%. The PCR-RFLP adapted method was effective in low and medium resolution histocompatibility evaluations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Computer software can be used to predict orthognathic surgery outcomes. The aim of this study was to subjectively compare the soft-tissue surgical simulations of 2 software programs. Methods: Standard profile pictures were taken of 10 patients with a Class III malocclusion and a concave facial profile who were scheduled for double-jaw orthognathic surgery. The patients had horizontal maxillary deficiency or horizontal mandibular excess. Two software programs (Dentofacial Planner Plus [Dentofacial Software, Toronto, Ontario, Canada] and Dolphin Imaging [version 9.0, Dolphin Imaging Software, Canoga Park, Calif]) were used to predict the postsurgical profiles. The predictive images were compared with the actual final photographs. One hundred one orthodontists, oral-maxillofacial surgeons, and general dentists evaluated the images and were asked whether they would use either software program to plan treatment for, or to educate, their patients. Results: Statistical analyses showed differences between the groups when each point was judged. Dolphin Imaging software had better prediction of nasal tip, chin, and submandibular area. Dentofacial Planner Plus software was better in predicting nasolabial angle, and upper and lower lips. The total profile comparison showed no statistical difference between the softwares. Conclusions: The 2 types of software are similar for obtaining 2-dimensional predictive profile images of patients with Class III malocclusion treated with orthognathic surgery. (Am J Orthod Dentofacial Orthop 2010; 137: 452.e1-452.e5)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tendency of displacement of the supporting structures of the distal extension removable partial denture (DERPD) associated to the implant with different inclinations of alveolar ridge and implant localizations through a two-dimensional finite-element method. Sixteen mandibular models were fabricated, presenting horizontal, distally descending, distally ascending, or descending-ascending ridges. All models presented the left canine and were rehabilitated with conventional DERPD or implant-retained prosthesis with the ERA system. The models were obtained by the AutoCAD software and transferred to the finite-element software ANSYS 9.0 for analysis. A force of 50 N was applied on the cusp tips of the teeth, with 5 points of loading of 10 N. The results were visualized by displacement maps. For all ridge inclinations, the assembly of the DERPD with distal plate retained by an anterior implant exhibited the lowest requisition of the supporting structures. The highest tendency of displacement occurred in the model with distally ascending ridge with incisal rest. It was concluded that the association of the implant decreased the displacement of the DERPD, and the anterior positioning of the implant associated to the DERPD with the distal plate preserved the supporting structures for all ridges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)