991 resultados para tensor imaging-detects


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The overall aim of this study was to assess the accuracy, reproducibility and stability of a high resolution passive stereophotogrammetry system to image a female mannequin torso, to validate measurements made on the textured virtual surface compared with those obtained using manual techniques and to develop an approach to make objective measurements of the female breast. 3D surface imaging was carried out on a textured female torso and measurements made in accordance with the system of mammometrics. Linear errors in measurements were less than 0.5 mm, system calibration produced errors of less than 1.0 mm over 94% over the surface and intra-rater reliability measured by ICC = 0.999. The mean difference between manual and digital curved surface distances was 1.36 mm with maximum and minimum differences of 3.15 mm and 0.02 mm, respectively. The stereophotogrammetry system has been demonstrated to perform accurately and reliably with specific reference to breast assessment. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is an evaluation of quantitative measurements of piezoresponse force microscopy for nanoscale characterization of ferroelectric films. To this end, we investigate how the piezoresponse phase difference Delta Phi between c domains depends on the frequency omega of the applied ac field much lower than the cantilever first resonance frequency. The main specimen under study was a 102 nm thick film of Pb(Zr(0.2)Ti(0.8))O(3). For the sake of comparison, a 100 nm thick PbTiO(3) film was also used. From our measurements, we conclude a frequency dependent behavior Delta Phi similar to omega(-1), which can only be partially explained by the presence of adsorbates on the surface. (C) 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural and functional change in the microcirculation in type 1 diabetes mellitus predicts future end-organ damage and macrovascular events. We explored the utility of novel signal processing techniques to detect and track change in ocular hemodynamics in patients with this disease. 24 patients with uncomplicated type 1 diabetes mellitus, and 18 age-and-sex matched control subjects were studied. Doppler ultrasound was used to interrogate the carotid and ophthalmic arteries and digital photography to image the retinal vasculature. Frequency analysis algorithms were applied to quantify velocity waveform structure and retinal photographic data at baseline and following inhalation of 100% oxygen. Frequency data was compared between groups. No significant differences were found in the resistive index between groups at baseline or following inhaled oxygen. Frequency analysis of the Doppler flow velocity waveforms identified significant differences in bands 3-7 between patients and controls in data captured from the ophthalmic artery (p<0.01 for each band). In response to inhaled oxygen, changes in the frequency band amplitudes were significantly greater in control subjects compared with patients (p<0.05). Only control subjects demonstrated a positive correlation (R=0.61) between change in retinal vessel diameter and frequency band amplitudes derived from ophthalmic artery waveform data. The use of multimodal signal processing techniques applied to Doppler flow velocity waveforms and retinal photographic data identified preclinical change in the ocular microcirculation in patients with uncomplicated diabetes mellitus. An impaired autoregulatory response of the retinal microvasculature may contribute to the future development of retinopathy in such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The production of shock- and collimated jet-like features is recorded from the self-emission of a plasma using a 16- frame camera, which can show the progression of the interaction over short (100s ns) durations. A cluster of laser beams, with intensity 1015 W/cm2, was focused onto a planar aluminum foil to produce a plasma that expanded into 0.7 mbar of argon gas. The acquisition of 16 ultrafast images on a single shot allows prompt spatial and temporal characterization of the plasma and enables the velocity of the jet- and shock-like features to be calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spectroscopic capability of the photon scanning tunneling microscope is exploited to study directly the launch and propagation of surface plasmons on thin silver films. Two input beams, of different wavelength, are incident through the prism in a prism-Ag film-air-fibre tip system. Both excite surface plasmons at the Ag-air interface and light of both wavelengths is coupled into the fibre probe via the respective surface plasmon evanescent fields. One laser beam is used for instrument control. The second, or probe beam is tightly focused on the sample, within the area of the unfocused or control beam, giving a well-defined and symmetrical, confined surface plasmon launch site. However, the image at the probe wavelength is highly asymmetrical in section with an exponential tail extending beyond one side of the launch site. This demonstrates in a very direct fashion;the propagation of surface plasmons; a propagation length of similar to 11.7 mu m is measured at a probe wavelength of 543.5 nm. On rough Ag films the excitation of localised scattering centres is also observed in addition to the launch of delocalised surface plasmons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of gamma-H2AX foci in blood lymphocytes is a promising approach for rapid dose estimation to support patient triage after a radiation accident but has one major drawback: the rapid decline of foci levels post-exposure cause major uncertainties in situations where the exact timing between exposure and blood sampling is unknown. To address this issue, radiation-induced apoptosis (RIA) in lymphocytes was investigated using fluorogenic inhibitors of caspases (FLICA) as an independent biomarker for radiation exposure, which may complement the gamma-H2AX assay. Ex vivo X-irradiated peripheral blood lymphocytes from 17 volunteers showed dose-and time-dependent increases in radiation-induced apoptosis over the first 3 days after exposure, albeit with considerable interindividual variation. Comparison with gamma-H2AX and 53BP1 foci counts suggested an inverse correlation between numbers of residual foci and radiation-induced apoptosis in lymphocytes at 24 h postirradiation (P = 0.007). In T-helper (CD4), T-cytotoxic (CD8) and B-cells (CD19), some significant differences in radiation induced DSBs or apoptosis were observed, however no correlation between foci and apoptosis in lymphocyte subsets was observed at 24 h postirradiation. While gamma-H2AX and 53BP1 foci were rapidly induced and then repaired after exposure, radiation-induced apoptosis did not become apparent until 24 h after exposure. Data from six volunteers with different ex vivo doses and post-exposure times were used to test the capability of the combined assay. Results show that simultaneous analysis of gamma-H2AX and radiation-induced apoptosis may provide a rapid and more accurate triage tool in situations where the delay between exposure and blood sampling is unknown compared to gamma-H2AX alone. This combined approach may improve the accuracy of dose estimations in cases where blood sampling is performed days after the radiation exposure. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that Kraus' property $ S_{\sigma }$ is preserved under taking weak* closed sums with masa-bimodules of finite width and establish an intersection formula for weak* closed spans of tensor products, one of whose terms is a masa-bimodule of finite width. We initiate the study of the question of when operator synthesis is preserved under the formation of products and prove that the union of finitely many sets of the form $ \kappa \times \lambda $, where $ \kappa $ is a set of finite width while $ \lambda $ is operator synthetic, is, under a necessary restriction on the sets $ \lambda $, again operator synthetic. We show that property $ S_{\sigma }$ is preserved under spatial Morita subordinance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that, if M is a subspace lattice with the property that the rank one subspace of its operator algebra is weak* dense, L is a commutative subspace lattice and P is the lattice of all projections on a separable Hilbert space, then L⊗M⊗P is reflexive. If M is moreover an atomic Boolean subspace lattice while L is any subspace lattice, we provide a concrete lattice theoretic description of L⊗M in terms of projection valued functions defined on the set of atoms of M . As a consequence, we show that the Lattice Tensor Product Formula holds for AlgM and any other reflexive operator algebra and give several further corollaries of these results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To conduct a prospective evaluation to determine the utility of the BTA stat test in the detection of upper tract transitional cell carcinoma (UTTCC). Monitoring for UTTCC currently relies on invasive procedures such as upper tract imaging, ureteral washing cytology (UWC) and/or ureteroscopy, or voided urine cytology (VUC). The BTA stat test is a sensitive qualitative immunoassay that detects human complement factor H-related protein in voided urine.

Methods. A total of 81 patients participated, 27 with histopathologically confirmed UTTCC, 26 with upper tract calculi, and 28 with microscopic hematuria but no evidence of urologic disease. Voided specimens collected before surgery or treatment were tested with the BTA stat test and VUC. UWC was performed in specimens collected by a ureteral catheter.

Results. The BTA stat test was significantly more sensitive and specific than VUC or UWC. The overall sensitivity for each was 82%, 11%, and 48%; the specificity was 89%, 54%, and 33%. The positive predictive value for the BTA stat test was 79% and the negative predictive value was 91%, both the highest of the three tests.

Conclusions. The BTA stat test was superior to VUC and UWC in the detection of UTTCC. These results may support the adoption of a less aggressive follow-up policy when monitoring for UTTCC when the BTA stat result is negative. If cystoscopy is negative and the BTA stat test is positive, upper tract investigations should be expedited and, if the bladder is in place, bladder biopsies performed. (C) 2001, Elsevier Science Inc.