985 resultados para system call frequencies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The P System antigens have been detected in numerous parasites, bacterias and viruses, nevertheless the clinical significance is still unknown. The aim was to study the presence of P1 antigenic determiners in A. lumbricoides extracts by means of the use of 6 different monoclonal antibodies of well-known concentrations and Ig class. We worked with 14 A. lumbricoides extracts. Inhibition Agglutination Test was made in a bromelin enzymatic medium and 4 ºC temperature. Titre, Score and Sensitivity Parameter were determined for each monoclonal antibody against red cells suspension used as revealing system. Ten extracts inhibited the agglutination of all anti P1 monoclonal antibodies. The 4 remaining extracts only inhibited the agglutination of some of them. It is demonstrated that the extracts have P1 activity. This activity is independent of titre, Score, Sensitivity Parameter, concentration and Ig class and it depends on the epitope at which the monoclonal antibody is directed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this project, one of the proposals of the EPS@ISEP 2014 Spring, was to develop an Aquaponics System. Over recent years Aquaponics systems have received increased attention due to its possibilities in helping reduce strain on resources within 1st and 3rd world countries. Aquaponics is the combination of Hydroponics and Aquaculture and mimics a natural environment in order to successfully apply and enhance the understanding of natural cycles within an indoor process. By using this knowledge of natural cycles it was possible to create a system with the capabilities similar to that of a natural environment with the benefits of electronic adaptions to enhance the overall efficiency of the system. The multinational team involved in its development was composed of five students, from five countries and fields of study. This paper covers their solution, involving overall design, the technology involved and the benefits it could bring to the current market. The team was able to achieve the final rendered Computer Aided Design (CAD) drawings, successfully performed all the electronic testing, and designed a solution under budget. Furthermore, the solution presented was deeply studied from the sustainability viewpoint and the team also developed a product specific marketing plan. Finally, the students involved in this project obtained new knowledge and skills.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on a retrospective case-control study we evaluated the score system adopted by the Ministry of Health of Brazil (Ministério da Saúde - MS), to diagnose pulmonary tuberculosis (PTB) in childhood. This system is independent of bacteriological or histopathological data to define a very likely (> or = 40 points), possible (30-35 points) or unlikely (< or = 25 points) diagnosis of tuberculosis. Records of hospitalized non-infected HIV children at the Instituto de Puericultura e Pediatria Martagão Gesteira of Federal University of Rio de Janeiro (IPPMG-UFRJ), were reviewed. Patients were adjusted for age and divided in two different groups: 45 subjects in the case group (culture-positive) [mean of age = 10.64 mo; SD 9.66]; and 96 in the control group (culture-negative and clinic criteria that dismissed the disease) [mean of age = 11.79 mo.; SD 11.31]. Among the variables analyzed, the radiological status had the greater impact into the diagnosis (OR = 25.39), followed by exposure to adult with tuberculosis (OR = 10.67), tuberculin skin test >10mm (OR = 8.23). The best cut-off point to the diagnosis of PTB was 30 points, where the score system was more accurate, with sensitivity of 88.9% and specificity of 86.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A. lumbricoides has been associated to the ABO System by various authors. The objective was to detect ABO System epitopes in A. lumbricoides of groups O, A, B and AB patients. 28 adult parasites were obtained from children to be used as assay material. The patients ABO blood groups were determined. Extracts of A. lumbricoides [AE] were prepared by surgical remotion of the cuticle and refrigerated mechanical rupture. Agglutination Inhibition (AI) and Hemoagglutination Kinetics (HK) tests were used with the [AE]. Of the 28 [AE], eight belonged to O group patients, 15 to A group, three to B group and the remaining two to AB children. The AI Test showed A epitopes in two [AE] of group A patients and B epitopes in two [AE] of group B patients. The HK Test showed B antigenic determiners in two [AE] of group B patients and in two [AE] of group AB patients as well as A antigenic determiners in one [AE] of A group patient. Of the 28 [AE] studied in both tests B epitopes were detected in all [AE] from B and AB patients and A epitopes in three of the 15 [AE] of group A patients. The experiments carried out suggest that A. lumbricoides might absorb A and B antigens from the host, and/or modify the cuticular carbohydrates expression as a kind of antigenic mimicry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maintaining a high level of data security with a low impact on system performance is more challenging in wireless multimedia applications. Protocols that are used for wireless local area network (WLAN) security are known to significantly degrade performance. In this paper, we propose an enhanced security system for a WLAN. Our new design aims to decrease the processing delay and increase both the speed and throughput of the system, thereby making it more efficient for multimedia applications. Our design is based on the idea of offloading computationally intensive encryption and authentication services to the end systems’ CPUs. The security operations are performed by the hosts’ central processor (which is usually a powerful processor) before delivering the data to a wireless card (which usually has a low-performance processor). By adopting this design, we show that both the delay and the jitter are significantly reduced. At the access point, we improve the performance of network processing hardware for real-time cryptographic processing by using a specialized processor implemented with field-programmable gate array technology. Furthermore, we use enhanced techniques to implement the Counter (CTR) Mode with Cipher Block Chaining Message Authentication Code Protocol (CCMP) and the CTR protocol. Our experiments show that it requires timing in the range of 20–40 μs to perform data encryption and authentication on different end-host CPUs (e.g., Intel Core i5, i7, and AMD 6-Core) as compared with 10–50 ms when performed using the wireless card. Furthermore, when compared with the standard WiFi protected access II (WPA2), results show that our proposed security system improved the speed to up to 3.7 times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signal-to-interference ratio (SIR) performance of a multiband orthogonal frequency division multiplexing ultra-wideband system with residual timing offset is investigated. To do so, an exact mathematical derivation of the SIR of this system is derived. It becomes obvious that, unlike a cyclic prefixing based system, a zero padding based system is sensitive to residual timing offset.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As of today, AUTOSAR is the de facto standard in the automotive industry, providing a common software architec- ture and development process for automotive applications. While this standard is originally written for singlecore operated Elec- tronic Control Units (ECU), new guidelines and recommendations have been added recently to provide support for multicore archi- tectures. This update came as a response to the steady increase of the number and complexity of the software functions embedded in modern vehicles, which call for the computing power of multicore execution environments. In this paper, we enumerate and analyze the design options and the challenges of porting AUTOSAR-based automotive applications onto multicore platforms. In particular, we investigate those options when considering the emerging many- core architectures that provide a more scalable environment than the traditional multicore systems. Such platforms are suitable to enable massive parallel execution, and their design is more suitable for partitioning and isolating the software components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

4th International Conference on Future Generation Communication Technologies (FGCT 2015), Luton, United Kingdom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. A Biomimetic Sensor Potentiometric System was developed for assessment of doxycycline (DOX) antibiotic. The molecularly imprinted polymer (MIP) was synthesized by using doxycycline as a template molecule, methacrylic acid (MAA) and/or acrylamide (AA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensing elements were fabricated by the inclusion of DOX imprinted polymers in polyvinyl chloride (PVC) matrix. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near-Nernstian response. MIP/MAA membrane sensor was incorporated in flow-through cells and used as detectors for flow injection analysis (FIA) of DOX. The method has the requisite accuracy, sensitivity and precision to assay DOX in tablets and biological fluids.