987 resultados para atomic resolution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). Using scanning spectrometers commercially available today, a large relative error, DELTA(A) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. The emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. A quantitative relation between DELTA(A) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of Gaussian line profiles. The agreement between calculated and experimental DELTA(A) is also illustrated. The DELTA(A) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where DELTA(A) decreases with an increase in the ratio. Compared with dlambda, the effect of deltalambda is generally less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extended Goldman-Shen pulse sequence was used to observe indirectly the proton spin diffusion in the blends of polystyrene (PS) with poly(2,6-dimethyl-1,4-phenylene oxides) (PPO). The results indicate that the average distance between PS and PPO is less than 5 angstrom in the intimately mixed phase, but there are heterogeneous domains on a 100-angstrom scale. The data of spin relaxation of carbons, T1(C), for homopolymers and their blends suggest that there is a strong pi-pi electron conjugation interaction between the aromatic rings of PS and those of PPO, while the aromatic rings of PPO drive the aromatic rings of PS to move cooperatively. It is the cooperative motion that markedly improves the impact strength of PS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of least-squres polynomial smoothing in ICP-AES is discussed and a method of points insertion into spectral scanning intervals is proposed in the present paper. Optimal FWHM/SR ratio can be obtained, and distortion of smoothed spectra can be avoided by use of the recommended method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a laser induced sensitized fluorescence spectrometry for measuring the spontaneous emission branching ratios o?the transitions from the ten levels 5f36d7s7p-7M7, 5f36d7s7p-7L6, 5f37s27p-5K6, 5f26d27s2 - 5L7, 5f46d7s - 7L6, (17,070cm-1)-5L6, 5f26d27s2-5K6, 6d7s7p-7L5, 5f36d7s7p-7K5 and 5f26d27s2-5I5 to the ground state of atomic uranium (UI) for the first time. Their relative oscillator strengths have been measured by means of hollow cathode discharge (HCD) emission spectrometry. The radiative...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper alms at illustrating the impact of spatial difference scheme and spatial resolution on the performance of Arakawa A-D grids in physical space. Linear shallow water equations are discretized and forecasted on Arakawa A-D grids for 120-minute using the ordinary second-order (M and fourth-order (C4) finite difference schemes with the grid spacing being 100 km, 10 km and I km, respectively. Then the forecasted results are compared with the exact solution, the result indicates that when the grid spacing is I kin, the inertial gravity wave can be simulated on any grid with the same results from C2 scheme or C4 scheme, namely the impact of variable configuration is neglectable; while the inertial gravity wave is simulated with lengthened grid spacing, the effects of different variable configurations are different. However, whether for C2 scheme or for C4 scheme, the RMS is minimal (maximal) on C (D) grid. At the same time it is also shown that when the difference accuracy increases from C2 scheme to C4 scheme, the resulted forecasts do not uniformly decrease, which is validated by the change of the group A velocity relative error from C2 scheme to C4 scheme. Therefore, the impact of the grid spacing is more important than that of the difference accuracy on the performance of Arakawa A-D grid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of hydride generation-atomic fluorescence spectrometry was proposed in the present paper for the determination of trace arsenic and selenium in jellyfish. The samples were treated by the combination of microwave digestion and lyophilization. The optimal conditions for treating and analyzing samples were established. The problem of the effect of the superfluous acid in the digesting solution on the results was solved, and the influence of coexisting foreign ions on the determination of arsenic and selenium was investigated. The accuracy of the method was confirmed by the method of standard additions. This method proved to be simple, rapid and repeatable, and is suitable for the analysis of biologic samples containing water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new technique was developed for characterisation of stainless steel to intergramilar stress corrosion cracking by atomic force microscopy. The technique proved to be effective in sensitisation identification of AISI 304 stainless steel and might be promising in sensitisation identification of other stainless steels. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

碳纳米管的小直径、高纵横比、高强度和高弹性、优良的耐磨损性能以及独特的电学和化学特性,使其成为高分辨率原子力显微镜的理想探针针尖。本文根据制作工艺的特点,综述现有碳纳米管探针的代表性研究和制作方法:组装式和生长式。组装式是通过手工、电场或磁场的方式将制备好的碳纳米管粘附到常规硅探针的末端;而生长式是在常规硅探针末端或悬臂梁上定点催化生长出一定直径和长度的CNT。最后指出这些方法目前存在的主要问题。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

研制了一种检测渗透到金属设备中的原子氢浓度的探测仪,该探测仪的渗氢电流测量范围为0~400~4000μA.在40OμA,仪器自动切换量程.在400μA以下的量程段,仪器的分辨力为0.1μA.渗氢电流信号的测量精度为±1%.传感器的背景电流。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method of synthesizing protein chiral stationary phase (protein-CSP) is proposed with 2,4,6-trichloro-1,3,5-triazine as the activator. The bovine serum albumin (BSA) based chiral columns (150x4.6 mm I.D.) were prepared successfully within 8 h. With tryptophan as the probe solute, it was observed that the BSA immobilized by this method had a better ability to distinguish enantiomers than that activated by glutaric dialdehyde. This may be due to the well-maintained BSA conformation and the larger amount of BSA immobilized on the silica gel. The BSA-CSP prepared by this method was relatively stable under experimental conditions, and the resolution of 13 chiral compounds was achieved. The coupling reaction in this method is mild, reliable and reproducible; it is also suitable for the immobilization of various biopolymers in the preparation of bioreactor, biosensor and affinity chromatography columns. (C) 2000 Elsevier Science B.V. All rights reserved.