990 resultados para Super-Gaussian pulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The compression properties of octave-spanning supercontinuum spectra generated in photonic crystal fibers are studied using stochastic nonlinear Schrödinger equation simulations. The conditions under which sub-5 fs pulses can be obtained after compression are identified. © 2004 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thanks to a passive cavity configuration, modulational instability in fibers is successfully observed, for the first time to our knowledge, in the continuous-wave regime. Our technique provides a new means of generating all-optically ultrahigh-repetition-rate pulse trains and opens up new possibilities for the fundamental study of modulational instability and related phenomena. © 2001 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traffic policing and bandwidth management strategies at the User Network Interface (UNI) of an ATM network are investigated by simulation. The network is assumed to transport real time (RT) traffic like voice and video as well as non-real time (non-RT) data traffic. The proposed policing function, called the super leaky bucket (S-LB), is based on the leaky bucket (LB), but handles the three types of traffic differently according to their quality of service (QoS) requirements. Separate queues are maintained for RT and non-RT traffic. They are normally served alternately, but if the number of RT cells exceeds a threshold, it gets non-pre-emptive priority. Further increase of the RT queue causes low priority cells to be discarded. Non-RT cells are buffered and the sources are throttled back during periods of congestion. The simulations clearly demonstrate the advantages of the proposed strategy in providing improved levels of service (delay, jitter and loss) for all types of traffic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods for serial generation of droplets from a liquid jet are shortly reviewed. A method of liquid metal droplet generation based on AC high frequency magnetic field is considered in detail. Numerical model for direct simulation of the time dependent droplet generation process is presented. Computed examples demonstrate the liquid silicon droplet formation for the cases of 500-1500 μm diameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review of 'Super Crunchers: How Anything Can Be Predicted' by Ian Ayres, published by John Murray, 2007 (ISBN 0-719-564638)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse design is investigated for time-reversal (TR) imaging as applied to ultrawideband (UWB) breast cancer detection. Earlier it has been shown that a suitably-designed UWB pulse may help to improve imaging performance for a single-tumor breast phantom with predetermined lesion properties. The current work considers the following more general and practical situations: presence of multiple malignancies with unknown tumor size and dielectric properties. Four pulse selection criteria are proposed with each focusing on one of the following aspects: eliminating signal clutter generated by tissue inhomogeneities, canceling mutual interference among tumors, improving image resolution, and suppressing artifacts created by sidelobe of the target response. By applying the proposed criteria, the shape parameters of UWB waveforms with desirable characteristics are identified through search of all the possible pulses. Simulation example using a numerical breast phantom, comprised of two tumors and structured clutter distribution, demonstrates the effectiveness of the proposed approach. Specifically, a tradeoff between the image resolution and signal-to-clutter contrast (SCC) is observed in terms of selection of the excitation waveforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is almost a tradition that celluloid (or digital) villains are represented with some characteristics that remind us the real political enemies of the producer country of the film, or even enemies within the country according to the particular ideology that sustains the film. The case of Christopher Nolan The Dark Knight trilogy, analyzed here, is representative of this trend for two reasons. First, because it gets marked by political radicalization conducted by the US government after the attack of September 11, 2001. Secondly, because it offers a profuse gallery of villains who are outside the circle of friends as the new doctrine “either with us or against us” opened by George Bush for the XXI century. This gallery includes from the very terrorists who justify the War on Terror (Ra's al Ghul, the Joker), to the “radical left” (Bane, Talia al Ghul) including liberal politicians (Harvey Dent), and corrupt that take advantage of the softness of the law to commit crimes with impunity (Dr. Crane, the Scarecrow).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic pulse reflectometry is used to reconstruct the internal bore profile of trumpet and cornet leadpipe. The method distinguishes between radii differences as small as 0.03 mm, and has since been used by various UK-based brass instrument manufacturers as a diagnostic tool to detect defects that are significant enough to acoustically alter performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The state-by-state transient screening approach based on a pulse-response thin-zone TAP experiment is further developed whereby single-pulse kinetic tests are treated as small perturbations to catalyst compositions and analyzed using integral method of moments. Results on three primary kinetic characteristics, termed basic kinetic coefficients, are presented. These three coefficients were introduced as main observables from experimentally measured TAP-responses in a kinetic-model-free manner. Each was analytically determined from moments of responses with no assumption about the detailed kinetic model. In this paper, the inverse question of how well these coefficients represent the time evolution of the observed responses is addressed. Sets of three basic kinetic coefficients are calculated from model and experimental responses and these calculated values are used to generate 3-coefficient curves in a kinetic-model-free manner. The comparison of these 3-coefficient curves with original responses shows that three basic kinetic coefficients can be sufficient to describe the observed kinetics of exit flow time dependencies with no assumption regarding the detailed kinetic model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reduced arterial compliance precedes changes in blood pressure, which may be mediated through alterations in vessel wall matrix composition. We investigated the effect of the collagen type I-1 gene (COL1A1) +2046G>T polymorphism on arterial compliance in healthy individuals. We recruited 489 subjects (251 men and 238 women; mean age, 22.6±1.6 years). COL1A1 genotypes were determined using polymerase chain reaction and digestion by restriction enzyme Bal1. Arterial pulse wave velocities were measured in 3 segments, aortoiliac (PWVA), aortoradial (PWVB), and aorto-dorsalis-pedis (PWVF), as an index of compliance using a noninvasive optical method. Data were available for 455 subjects. The sample was in Hardy-Weinberg equilibrium with genotype distributions and allele frequencies that were not significantly different from those reported previously. The T allele frequency was 0.22 (95% confidence interval, 0.19 to 0.24). Two hundred eighty-three (62.2%) subjects were genotype GG, 148 (35.5%) subjects were genotype GT, and 24 (5.3%) subjects were genotype TT. A comparison of GG homozygotes with GT and TT individuals demonstrated a statistically significant association with arterial compliance: PWVF 4.92±0.03 versus 5.06±0.05 m/s (ANOVA, P=0.009), PWVB 4.20±0.03 versus 4.32±0.04 m/s (ANOVA, P=0.036), and PWVA 3.07±0.03 versus 3.15±0.03 m/s (ANOVA, P=0.045). The effects of genotype were independent of age, gender, smoking, mean arterial pressure, body mass index, family history of hypertension, and activity scores. We report an association between the COL1A1 gene polymorphism and arterial compliance. Alterations in arterial collagen type 1A deposition may play a role in the regulation of arterial compliance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measures of entanglement, fidelity, and purity are basic yardsticks in quantum-information processing. We propose how to implement these measures using linear devices and homodyne detectors for continuous-variable Gaussian states. In particular, the test of entanglement becomes simple with some prior knowledge that is relevant to current experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the nonclassicality of a photon-subtracted Gaussian field, which was produced in a recent experiment, using negativity of the Wigner function and the nonexistence of well-behaved positive P function. We obtain the condition to see negativity of the Wigner function for the case including the mixed Gaussian incoming field, the threshold photodetection and the inefficient homodyne measurement. We show how similar the photon-subtracted state is to a superposition of coherent states.