Distinguishing between similar tubular objects using pulse reflectometry: a study of trumpet and cornet leadpipes
Data(s) |
01/05/2002
|
---|---|
Resumo |
Acoustic pulse reflectometry is used to reconstruct the internal bore profile of trumpet and cornet leadpipe. The method distinguishes between radii differences as small as 0.03 mm, and has since been used by various UK-based brass instrument manufacturers as a diagnostic tool to detect defects that are significant enough to acoustically alter performance. |
Formato |
application/pdf |
Identificador |
http://pure.qub.ac.uk/ws/files/315692/iop02.pdf http://www.scopus.com/inward/record.url?scp=0036574490&partnerID=8YFLogxK |
Idioma(s) |
eng |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Buick , J M , Kemp , J , Sharp , D B , Van Walstijn , M , Campbell , D M & Smith , R A 2002 , ' Distinguishing between similar tubular objects using pulse reflectometry: a study of trumpet and cornet leadpipes ' Measurement Science and Technology , vol 13 , no. 5 , pp. 750-757 . |
Palavras-Chave | #/dk/atira/pure/subjectarea/asjc/2500/2501 #Materials Science (miscellaneous) #/dk/atira/pure/subjectarea/asjc/2500/2503 #Ceramics and Composites #/dk/atira/pure/subjectarea/asjc/2500/2507 #Polymers and Plastics |