986 resultados para Muon spectrometer
Resumo:
The relative abundance of the heavy water isotopologue HDO provides a deeper insight into the atmospheric hydrological cycle. The SCanning Imaging Absorption spectroMeter for Atmospheric CartograpHY (SCIAMACHY) allows for global retrievals of the ratio HDO/H2O in the 2.3 micron wavelength range. However, the spectroscopy of water lines in this region remains a large source of uncertainty for these retrievals. We therefore evaluate and improve the water spectroscopy in the range 4174–4300 cm−1 and test if this reduces systematic uncertainties in the SCIAMACHY retrievals of HDO/H2O. We use a laboratory spectrum of water vapour to fit line intensity, air broadening and wavelength shift parameters. The improved spectroscopy is tested on a series of ground-based high resolution FTS spectra as well as on SCIAMACHY retrievals of H2O and the ratio HDO/H2O. We find that the improved spectroscopy leads to lower residuals in the FTS spectra compared to HITRAN 2008 and Jenouvrier et al. (2007) spectroscopy, and the retrievals become more robust against changes in the retrieval window. For both the FTS and SCIAMACHY measurements, the retrieved total H2O columns decrease by 2–4% and we find a negative shift of the HDO/H2O ratio, which for SCIAMACHY is partly compensated by changes in the retrieval setup and calibration software. The updated SCIAMACHY HDO/H2O product shows somewhat steeper latitudinal and temporal gradients and a steeper Rayleigh distillation curve, strengthening previous conclusions that current isotope-enabled general circulation models underestimate the variability in the near-surface HDO/H2O ratio.
Resumo:
The ArgoNeuT liquid argon time projection chamber has collected thousands of neutrino and anti-neutrino events during an extended run period in the NuMI beam-line at Fermilab. This paper focuses on the main aspects of the detector layout and related technical features, including the cryogenic equipment, time projection chamber, read-out electronics, and off-line data treatment. The detector commissioning phase, physics run, and first neutrino event displays are also reported. The characterization of the main working parameters of the detector during data-taking, the ionization electron drift velocity and lifetime in liquid argon, as obtained from through-going muon data complete the present report.
Resumo:
With recent advances in mass spectrometry techniques, it is now possible to investigate proteins over a wide range of molecular weights in small biological specimens. This advance has generated data-analytic challenges in proteomics, similar to those created by microarray technologies in genetics, namely, discovery of "signature" protein profiles specific to each pathologic state (e.g., normal vs. cancer) or differential profiles between experimental conditions (e.g., treated by a drug of interest vs. untreated) from high-dimensional data. We propose a data analytic strategy for discovering protein biomarkers based on such high-dimensional mass-spectrometry data. A real biomarker-discovery project on prostate cancer is taken as a concrete example throughout the paper: the project aims to identify proteins in serum that distinguish cancer, benign hyperplasia, and normal states of prostate using the Surface Enhanced Laser Desorption/Ionization (SELDI) technology, a recently developed mass spectrometry technique. Our data analytic strategy takes properties of the SELDI mass-spectrometer into account: the SELDI output of a specimen contains about 48,000 (x, y) points where x is the protein mass divided by the number of charges introduced by ionization and y is the protein intensity of the corresponding mass per charge value, x, in that specimen. Given high coefficients of variation and other characteristics of protein intensity measures (y values), we reduce the measures of protein intensities to a set of binary variables that indicate peaks in the y-axis direction in the nearest neighborhoods of each mass per charge point in the x-axis direction. We then account for a shifting (measurement error) problem of the x-axis in SELDI output. After these pre-analysis processing of data, we combine the binary predictors to generate classification rules for cancer, benign hyperplasia, and normal states of prostate. Our approach is to apply the boosting algorithm to select binary predictors and construct a summary classifier. We empirically evaluate sensitivity and specificity of the resulting summary classifiers with a test dataset that is independent from the training dataset used to construct the summary classifiers. The proposed method performed nearly perfectly in distinguishing cancer and benign hyperplasia from normal. In the classification of cancer vs. benign hyperplasia, however, an appreciable proportion of the benign specimens were classified incorrectly as cancer. We discuss practical issues associated with our proposed approach to the analysis of SELDI output and its application in cancer biomarker discovery.
Resumo:
The 1s-2s interval has been measured in the muonium (;mgr;(+)e(-)) atom by Doppler-free two-photon pulsed laser spectroscopy. The frequency separation of the states was determined to be 2 455 528 941.0(9.8) MHz, in good agreement with quantum electrodynamics. The result may be interpreted as a measurement of the muon-electron charge ratio as -1-1.1(2.1)x10(-9). We expect significantly higher accuracy at future high flux muon sources and from cw laser technology.
Resumo:
Nitrous oxide fluxes were measured at the Lägeren CarboEurope IP flux site over the multi-species mixed forest dominated by European beech and Norway spruce. Measurements were carried out during a four-week period in October–November 2005 during leaf senescence. Fluxes were measured with a standard ultrasonic anemometer in combination with a quantum cascade laser absorption spectrometer that measured N2O, CO2, and H2O mixing ratios simultaneously at 5 Hz time resolution. To distinguish insignificant fluxes from significant ones it is proposed to use a new approach based on the significance of the correlation coefficient between vertical wind speed and mixing ratio fluctuations. This procedure eliminated roughly 56% of our half-hourly fluxes. Based on the remaining, quality checked N2O fluxes we quantified the mean efflux at 0.8±0.4 μmol m−2 h−1 (mean ± standard error). Most of the contribution to the N2O flux occurred during a 6.5-h period starting 4.5 h before each precipitation event. No relation with precipitation amount could be found. Visibility data representing fog density and duration at the site indicate that wetting of the canopy may have as strong an effect on N2O effluxes as does below-ground microbial activity. It is speculated that above-ground N2O production from the senescing leaves at high moisture (fog, drizzle, onset of precipitation event) may be responsible for part of the measured flux.
Resumo:
Mount Etna, Italy, is one of the most active volcanoes in the world, and is also regarded as one of the strongest volcanic sources of sulfur dioxide (SO2) emissions to the atmosphere. Since October 2004, an automated ultraviolet (UV) spectrometer network (FLAME) has provided ground-based SO2 measurements with high temporal resolution, providing an opportunity to validate satellite SO2 measurements at Etna. The Ozone Monitoring Instrument (OMI) on the NASA Aura satellite, which makes global daily measurements of trace gases in the atmosphere, was used to compare SO2 amount released by the volcano during paroxysmal lava-fountaining events from 2004 to present. We present the first comparison between SO2 emission rates and SO2 burdens obtained by the OMI transect technique and OMI Normalized Cloud-Mass (NCM) technique and the ground-based FLAME Mini-DOAS measurements. In spite of a good data set from the FLAME network, finding coincident OMI and FLAME measurements proved challenging and only one paroxysmal event provided a good validation for OMI. Another goal of this work was to assess the efficacy of the FLAME network in capturing paroxysmal SO2 emissions from Etna, given that the FLAME network is only operational during daylight hours and some paroxysms occur at night. OMI measurements are advantageous since SO2 emissions from nighttime paroxysms can often be quantified on the following day, providing improved constraints on Etna’s SO2 budget.
Resumo:
The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) has been used to quantify SO2 emissions from passively degassing volcanoes. This dissertation explores ASTER’s capability to detect SO2 with satellite validation, enhancement techniques and extensive processing of images at a variety of volcanoes. ASTER is compared to the Mini UV Spectrometer (MUSe), a ground based instrument, to determine if reasonable SO2 fluxes can be quantified from a plume emitted from Lascar, Chile. The two sensors were in good agreement with ASTER proving to be a reliable detector of SO2. ASTER illustrated the advantages of imaging a plume in 2D, with better temporal resolution than the MUSe. SO2 plumes in ASTER imagery are not always discernible in the raw TIR data. Principal Component Analysis (PCA) and Decorrelation Stretch (DCS) enhancement techniques were compared to determine how well they highlight a variety of volcanic plumes. DCS produced a consistent output and the composition of the plumes was easy to identify from explosive eruptions. As the plumes became smaller and lower in altitude they became harder to distinguish using DCS. PCA proved to be better at identifying smaller low altitude plumes. ASTER was used to investigate SO2 emissions at Lascar, Chile. Activity at Lascar has been characterized by cyclic behavior and persistent degassing (Matthews et al. 1997). Previous studies at Lascar have primarily focused on changes in thermal infrared anomalies, neglecting gas emissions. Using the SO2 data along with changes in thermal anomalies and visual observations it is evident that Lascar is at the end an eruptive cycle that began in 1993. Declining gas emissions and crater temperatures suggest that the conduit is sealing. ASTER and the Ozone Monitoring Instrument (OMI) were used to determine the annual contribution of SO2 to the troposphere from the Central and South American volcanic arcs between 2000 and 2011. Fluxes of 3.4 Tg/a for Central America and 3.7 Tg/a for South America were calculated. The detection limits of ASTER were explored. The results a proved to be interesting, with plumes from many of the high emitting volcanoes, such as Villarrica, Chile, not being detected by ASTER.
Resumo:
Volcán de Colima has been continuously erupting since the onset of dome growth in 1998. This period of unrest has had 4 prominent periods; 1998-1999, 2003, 2004-2005, and the current dome growth that began in February of 2007. Each of these episodes was marked by lava extrusion forming a dome and lava flows, followed by explosions that destroyed the dome. The Correlation Spectrometer (COSPEC) was used to determine SO2 emission rates on 164 days from May 2003 to February 2007, using both stationary ground based scans and some flight traverses. Scans were separated into the categories of explosive degassing and passive, or background degassing. These scans show variation in the SO2 flow rate from below detection limit (~3 t/d depending on environmental conditions) during background, passive emissions to a peak of 2949 t/d (34 kilograms/second) during an explosion on 9 October, 2004. Both passive and explosive degassing increased when there was lava extrusion in 2004 and with the increased explosive activity in 2005. These two different processes of degassing wax with each other when activity increases and wane together as well, indicating a parallel cyclicity in the volcanic eruption and degassing rates, where the conduit partially seals (pressurizes) between explosions. Colima’s gas and eruptive behavior is compared to similar systems such as Santiaguito and Soufrière Hills, Montserrat. About 2/3 of Colima’s SO2 degassing, amounting to 1.3 x 105 tonnes in 3.74 yrs has come in short lived small (VEI=0-1) vertical explosions that occurred at the rate of 100-3000explosions/ month, and the remaining third has occured in continuous passive degassing. Colima emits sulfur at a rate equivalent to about 0.04 to 0.08 wt % S, similar to other andesitic convergent plate boundary volcanoes. There has been an explosive destruction of the dome in every cycle for that past 5 years, and it is assumed that the current dome which began growth in February, 2007 (just at the end of this study) will be destroyed. Higher emission rates seen in the quiescence of 2006 may have eased the pressure at the time, resulting in the slow effusion of the current dome and lack of explosivity.
Resumo:
Anonymity systems maintain the anonymity of communicating nodes by camouflaging them, either with peer nodes generating dummy traffic or with peer nodes participating in the actual communication process. The probability of any adversary breaking down the anonymity of the communicating nodes is inversely proportional to the number of peer nodes participating in the network. Hence to maintain the anonymity of the communicating nodes, a large number of peer nodes are needed. Lack of peer availability weakens the anonymity of any large scale anonymity system. This work proposes PayOne, an incentive based scheme for promoting peer availability. PayOne aims to increase the peer availability by encouraging nodes to participate in the anonymity system by awarding them with incentives and thereby promoting the anonymity strength. Existing incentive schemes are designed for single path based approaches. There is no incentive scheme for multipath based or epidemic based anonymity systems. This work has been specifically designed for epidemic protocols and has been implemented over MuON, one of the latest entries to the area of multicasting based anonymity systems. MuON is a peer-to-peer based anonymity system which uses epidemic protocol for data dissemination. Existing incentive schemes involve paying every intermediate node that is involved in the communication between the initiator and the receiver. These schemes are not appropriate for epidemic based anonymity systems due to the incurred overhead. PayOne differs from the existing schemes because it involves paying a single intermediate node that participates in the network. The intermediate node can be any random node that participates in the communication and does not necessarily need to lie in the communication path between the initiator and the receiver. The light-weight characteristics of PayOne make it viable for large-scale epidemic based anonymity systems.
Resumo:
The purpose of this study is to detail and analyze the distribution, concentration, and loads of 5 organic compounds along Silver Bow Creek in Butte, Montana from the Municipal Wastewater treatment plant to the Warm Springs Ponds. The chemicals analyzed include Carbamazepine (pharmaceutical), Miconazole (fungicide) and three antibiotics – Sulfamethoxazole, Thiabendazole, and Ciprofloxacin. This project begins a 2 year study to analyze 6 additional compounds (11 compounds total), to develop an effective method to detail and analyze OWCs using Mass Spectrometer/Liquid chromatography system, and to aid in assessment of aquatic health and ongoing restoration work. The EPA method 1694 was used for analysis
Resumo:
The Plasma and Supra-Thermal Ion Composition (PLASTIC) instrument is one of four experiment packages on board of the two identical STEREO spacecraft A and B, which were successfully launched from Cape Canaveral on 26 October 2006. During the two years of the nominal STEREO mission, PLASTIC is providing us with the plasma characteristics of protons, alpha particles, and heavy ions. PLASTIC will also provide key diagnostic measurements in the form of the mass and charge state composition of heavy ions. Three measurements (E/qk, time of flight, ESSD) from the pulse height raw data are used to characterize the solar wind ions from the solar wind sector, and part of the suprathermal particles from the wide-angle partition with respect to mass, atomic number and charge state. In this paper, we present a new method for flight data analysis based on simulations of the PLASTIC response to solar wind ions. We present the response of the entrance system / energy analyzer in an analytical form. Based on stopping power theory, we use an analytical expression for the energy loss of the ions when they pass through a thin carbon foil. This allows us to model analytically the response of the time of flight mass spectrometer to solar wind ions. Thus we present a new version of the analytical response of the solid state detectors to solar wind ions. Various important parameters needed for our models were derived, based on calibration data and on the first flight measurements obtained from STEREO-A. We used information from each measured event that is registered in full resolution in the Pulse Height Analysis words and we derived a new algorithm for the analysis of both existing and future data sets of a similar nature which was tested and works well. This algorithm allows us to obtain, for each measured event, the mass, atomic number and charge state in the correct physical units. Finally, an important criterion was developed for filtering our Fe raw flight data set from the pulse height data without discriminating charge states.