985 resultados para FAST SCAN VOLTAMMETRIC DETERMINATIONS
Resumo:
This paper presents a performance analysis of reversible, fault tolerant VLSI implementations of carry select and hybrid decimal adders suitable for multi-digit BCD addition. The designs enable partial parallel processing of all digits that perform high-speed addition in decimal domain. When the number of digits is more than 25 the hybrid decimal adder can operate 5 times faster than conventional decimal adder using classical logic gates. The speed up factor of hybrid adder increases above 10 when the number of decimal digits is more than 25 for reversible logic implementation. Such highspeed decimal adders find applications in real time processors and internet-based applications. The implementations use only reversible conservative Fredkin gates, which make it suitable for VLSI circuits.
Resumo:
A novel and fast technique for cryptographic applications is designed and developed using the symmetric key algorithm “MAJE4” and the popular asymmetric key algorithm “RSA”. The MAJE4 algorithm is used for encryption / decryption of files since it is much faster and occupies less memory than RSA. The RSA algorithm is used to solve the problem of key exchange as well as to accomplish scalability and message authentication. The focus is to develop a new hybrid system called MARS4 by combining the two cryptographic methods with an aim to get the advantages of both. The performance evaluation of MARS4 is done in comparison with MAJE4 and RSA.
Resumo:
The presence of microcalcifications in mammograms can be considered as an early indication of breast cancer. A fastfractal block coding method to model the mammograms fordetecting the presence of microcalcifications is presented in this paper. The conventional fractal image coding method takes enormous amount of time during the fractal block encoding.procedure. In the proposed method, the image is divided intoshade and non shade blocks based on the dynamic range, andonly non shade blocks are encoded using the fractal encodingtechnique. Since the number of image blocks is considerablyreduced in the matching domain search pool, a saving of97.996% of the encoding time is obtained as compared to theconventional fractal coding method, for modeling mammograms.The above developed mammograms are used for detectingmicrocalcifications and a diagnostic efficiency of 85.7% isobtained for the 28 mammograms used.
Resumo:
In this paper, a novel fast method for modeling mammograms by deterministic fractal coding approach to detect the presence of microcalcifications, which are early signs of breast cancer, is presented. The modeled mammogram obtained using fractal encoding method is visually similar to the original image containing microcalcifications, and therefore, when it is taken out from the original mammogram, the presence of microcalcifications can be enhanced. The limitation of fractal image modeling is the tremendous time required for encoding. In the present work, instead of searching for a matching domain in the entire domain pool of the image, three methods based on mean and variance, dynamic range of the image blocks, and mass center features are used. This reduced the encoding time by a factor of 3, 89, and 13, respectively, in the three methods with respect to the conventional fractal image coding method with quad tree partitioning. The mammograms obtained from The Mammographic Image Analysis Society database (ground truth available) gave a total detection score of 87.6%, 87.6%, 90.5%, and 87.6%, for the conventional and the proposed three methods, respectively.
Resumo:
A differential pulse voltammetric sensor for the determination of tamsulosin hydrochloride (TAM) using multiwalled carbon nanotubes (MWNTs)–Nafion-modified glassy carbon electrode (GCE) has been developed. MWNTs were dispersed in water with the help of Nafion and were used to modify the surface of GCE via solvent evaporation. At MWNT-modified electrode, TAM gave a well-defined oxidation peak at a potential of 1084 mV in 0.1 M acetate buffer solution of pH 5. Compared to the bare electrode, the peak current of TAM showed a marked increase and the peak potential showed a negative deviation. The determination conditions, such as the amount of MWNT–Nafion suspension, pH of the supporting electrolyte and scan rate, were optimised. Under optimum conditions, the oxidation peak current was proportional to the concentration of TAM in the range 1 × 1023 M–3 × 1027 M with a detection limit of 9.8 × 1028 M. The developed sensor showed good stability, selectivity and was successfully used for the determination of TAM in pharmaceutical formulations and urine samples
Resumo:
Cochin University of Science & Technology
Resumo:
There is an enormous demand for chemical sensors in many areas and disciplines including chemistry, biology, clinical analysis, environmental science. Chemical sensing refers to the continuous monitoring of the presence of chemical species and is a rapidly developing field of science and technology. They are analytical devices which transform chemical information generating from a reaction of the analyte into an measurable signal. Due to their high selectivity, sensitivity, fast response and low cost, electrochemical and fluorescent sensors have attracted great interest among the researchers in various fields. Development of four electrochemical sensors and three fluorescent sensors for food additives and neurotransmitters are presented in the thesis. Based on the excellent properties of multi walled carbon nanotube (MWCNT), poly (L-cysteine) and gold nanoparticles (AuNP) four voltammetric sensors were developed for various food additives like propyl gallate, allura red and sunset yellow. Nanosized fluorescent probes including gold nanoclusters (AuNCs) and CdS quantum dots (QDs) were used for the fluorescent sensing of butylated hydroxyanisole, dopamine and norepinephrine. A total of seven sensors including four electrochemical sensors and three fluorescence sensors have been developed for food additives and neurotransmitters.
Resumo:
The photoionization of the Ne 2s-electrons was studied from threshold to 1 eV above threshold. The technique of photon-induced fluorescence spectroscopy was applied. Pronounced structures were observed resulting from autoionization of doubly excited atomic states. A threshold cross section of 0.17 Mb was determined.
Resumo:
We present a new algorithm called TITANIC for computing concept lattices. It is based on data mining techniques for computing frequent itemsets. The algorithm is experimentally evaluated and compared with B. Ganter's Next-Closure algorithm.
Resumo:
Der Einsatz der Particle Image Velocimetry (PIV) zur Analyse selbsterregter Strömungsphänomene und das dafür notwendige Auswerteverfahren werden in dieser Arbeit beschrieben. Zur Untersuchung von solchen Mechanismen, die in Turbo-Verdichtern als Rotierende Instabilitäten in Erscheinung treten, wird auf Datensätze zurückgegriffen, die anhand experimenteller Untersuchungen an einem ringförmigen Verdichter-Leitrad gewonnen wurden. Die Rotierenden Instabilitäten sind zeitabhängige Strömungsphänomene, die bei hohen aerodynamischen Belastungen in Verdichtergittern auftreten können. Aufgrund der fehlenden Phaseninformation kann diese instationäre Strömung mit konventionellen PIV-Systemen nicht erfasst werden. Die Kármánsche Wirbelstraße und Rotierende Instabilitäten stellen beide selbsterregte Strömungsvorgänge dar. Die Ähnlichkeit wird genutzt um die Funktionalität des Verfahrens anhand der Kármánschen Wirbelstraße nachzuweisen. Der mittels PIV zu visualisierende Wirbeltransport erfordert ein besonderes Verfahren, da ein externes Signal zur Festlegung des Phasenwinkels dieser selbsterregten Strömung nicht zur Verfügung steht. Die Methodik basiert auf der Kopplung der PIV-Technik mit der Hitzdrahtanemometrie. Die gleichzeitige Messung mittels einer zeitlich hochaufgelösten Hitzdraht-Messung ermöglicht den Zeitpunkten der PIV-Bilder einen Phasenwinkel zuzuordnen. Hierzu wird das Hitzdrahtsignal mit einem FFT-Verfahren analysiert, um die PIV-Bilder entsprechend ihrer Phasenwinkel zu gruppieren. Dafür werden die aufgenommenen Bilder auf der Zeitachse der Hitzdrahtmessungen markiert. Eine systematische Analyse des Hitzdrahtsignals in der Umgebung der PIV-Messung liefert Daten zur Festlegung der Grundfrequenz und erlaubt es, der markierten PIV-Position einen Phasenwinkel zuzuordnen. Die sich aus den PIV-Bildern einer Klasse ergebenden Geschwindigkeitskomponenten werden anschließend gemittelt. Aus den resultierenden Bildern jeder Klasse ergibt sich das zweidimensionale zeitabhängige Geschwindigkeitsfeld, in dem die Wirbelwanderung der Kármánschen Wirbelstraße ersichtlich wird. In hierauf aufbauenden Untersuchungen werden Zeitsignale aus Messungen in einem Verdichterringgitter analysiert. Dabei zeigt sich, dass zusätzlich Filterfunktionen erforderlich sind. Im Ergebnis wird schließlich deutlich, dass die Übertragung der anhand der Kármánschen Wirbelstraße entwickelten Methode nur teilweise gelingt und weitere Forschungsarbeiten erforderlich sind.