986 resultados para Bussone, Francesco, approximately 1385-1432.
Resumo:
In view of the established extrapulmonary cancer sites targeted by smoking a multiplicity of compounds, and mechanisms might be involved. It has been debated that smoking caused increased incidence of N-methylvaline at the N-terminus of haemoglobin. Because this could indicate a relevance of methylating nitrosamines in tobacco smoke, data are presented from an industrial cohort of 35 smokers and 21 non-smokers repeatedly monitored between 1994 and 1999. In general, N-methylvaline adduct levels in haemoglobin of smokers were approximately 50% higher than those of non-smokers. The smoking-induced methylation of haemoglobin is likely to be caused by dimethylnitrosamine (N-nitroso-dimethylamine), a major nitrosamine in side-stream tobacco smoke. The biomonitoring data emphasise the potential value of N-methylvaline as a smoking-related biomarker and call for intensified research on tobacco smoke compounds that lead to macromolecular methylation process.
Resumo:
Various forms of hydrogenated graphene have been produced to date by several groups, while the synthesis of pure graphane has not been achieved yet. The study of the interface between graphane, in all its possible hydrogenation configurations, and catalyst metal surfaces can be pivotal to assess the feasibility of direct CVD growth methods for this material. We investigated the adhesion of graphane to a Cu(111) surface by adopting the vdW-DF2-C09 exchange-correlation functional, which is able to describe dispersion forces. The results are further compared with the PBE and the LDA exchange-correlation functionals. We calculated the most stable geometrical configurations of the slab/graphane interface and evaluated how graphane's geometrical parameters are modified. We show that dispersion forces play an important role in the slab/graphane adhesion. Band structure calculations demonstrated that in the presence of the interaction with copper, the band gap of graphane is not only preserved, but also enlarged, and this increase can be attributed to the electronic charge accumulated at the interface. We calculated a substantial energy barrier at the interface, suggesting that CVD graphane films might act as reliable and stable insulating thin coatings, or also be used to form compound layers in conjunction with metals and semiconductors.
Resumo:
The transfer of chemical vapor deposited graphene is a crucial process, which can affect the quality of the transferred films and compromise their application in devices. Finding a robust and intrinsically clean material capable of easing the transfer of graphene without interfering with its properties remains a challenge. We here propose the use of an organic compound, cyclododecane, as a transfer material. This material can be easily spin coated on graphene and assist the transfer, leaving no residues and requiring no further removal processes. The effectiveness of this transfer method for few-layer graphene on a large area was evaluated and confirmed by microscopy, Raman spectroscopy, x-ray photoemission spectroscopy, and four-point probe measurements. Schottky-barrier solar cells with few-layer graphene were fabricated on silicon wafers by using the cyclododecane transfer method and outperformed reference cells made by standard methods.
Resumo:
This study demonstrates a novel technique of preparing drug colloid probes to determine the adhesion force between a model drug salbutamol sulphate (SS) and the surfaces of polymer microparticles to be used as carriers for the dispersion of drug particles from dry powder inhaler (DPI) formulations. Model silica probes of approximately 4 lm size, similar to a drug particle used in DPI formulations, were coated with a saturated SS solution with the aid of capillary forces acting between the silica probe and the drug solution. The developed method of ensuring a smooth and uniform layer of SS on the silica probe was validated using X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM). Using the same technique, silica microspheres pre-attached on the AFM cantilever were coated with SS. The adhesion forces between the silica probe and drug coated silica (drug probe) and polymer surfaces (hydrophilic and hydrophobic) were determined. Our experimental results showed that the technique for preparing the drug probe was robust and can be used to determine the adhesion force between hydrophilic/ hydrophobic drug probe and carrier surfaces to gain a better understanding on drug carrier adhesion forces in DPI formulations.
Resumo:
Deficiencies in iodine levels have been shown to seriously affect a child’s intellectual development and learning capacity.1 In South-East Asia, iodine deficiency remains a major public health concern. Approximately 30% of the region’s population of 503.6 million have insufficient iodine intake, and only 61% of households have access to iodized salt.1 For this reason, it is necessary to initiate effective, community-based health promotion activities that are targeted toward populations of various ages. A puppet show is one imaginative and entertaining method of health education that has been advocated for use in communicating positive health behaviours to children.2e5 The authors undertook a literature review and found no studies assessing the effectiveness of a puppet show to teach an iodine education programme...
Resumo:
Objectives: The purpose of this study was to investigate the characteristics associated with fatal and non-fatal low-speed vehicle run-over (LSVRO) events in relation to person, incident and injury characteristics, in order to identify appropriate points for intervention and injury prevention. Methods: Data on all known LSVRO events in Queensland, Australia, over 11 calendar years (1999–2009) were extracted from five different databases representing the continuum of care ( prehospital to fatality) and manually linked. Descriptive and multivariate analyses were used to analyse the sample characteristics in relation to demographics, health service usage, outcomes, incident characteristics, and injury characteristics. Results: Of the 1641 LSVRO incidents, 98.4% (n=1615) were non-fatal, and 1.6% were fatal (n=26). Over half the children required admission to hospital (56%, n=921); mean length of stay was 3.4 days. Younger children aged 0–4 years were more frequently injured, and experienced more serious injuries with worse outcomes. Patterns of injury (injury type and severity), injury characteristics (eg, time of injury, vehicle type, driver of vehicle, incident location), and demographic characteristics (such as socioeconomic status, indigenous status, remoteness), varied according to age group. Almost half (45.6%; n=737) the events occurred outside major cities, and approximately 10% of events involved indigenous children. Parents were most commonly the vehicle drivers in fatal incidents. While larger vehicles such as four-wheel drives (4WD) were most frequently involved in LSVRO events resulting in fatalities, cars were most frequently involved in non-fatal events. Conclusions: This is the first study, to the authors’ knowledge, to analyse the characteristics of fatal and non-fatal LSVRO events in children aged 0–15 years on a state-wide basis. Characteristics of LSVRO events varied with age, thus age-specific interventions are required. Children living outside major cities, and indigenous children, were over-represented in these data. Further research is required to identify the burden of injury in these groups.
Resumo:
Purpose Two diodes which do not require correction factors for small field relative output measurements are designed and validated using experimental methodology. This was achieved by adding an air layer above the active volume of the diode detectors, which canceled out the increase in response of the diodes in small fields relative to standard field sizes. Methods Due to the increased density of silicon and other components within a diode, additional electrons are created. In very small fields, a very small air gap acts as an effective filter of electrons with a high angle of incidence. The aim was to design a diode that balanced these perturbations to give a response similar to a water-only geometry. Three thicknesses of air were placed at the proximal end of a PTW 60017 electron diode (PTWe) using an adjustable “air cap”. A set of output ratios (ORfclin Det ) for square field sizes of side length down to 5 mm was measured using each air thickness and compared to ORfclin Det measured using an IBA stereotactic field diode (SFD). k fclin, f msr Qclin,Qmsr was transferred from the SFD to the PTWe diode and plotted as a function of air gap thickness for each field size. This enabled the optimal air gap thickness to be obtained by observing which thickness of air was required such that k fclin, f msr Qclin,Qmsr was equal to 1.00 at all field sizes. A similar procedure was used to find the optimal air thickness required to make a modified Sun Nuclear EDGE detector (EDGEe) which s “correction-free” in small field relative dosimetry. In addition, the feasibility of experimentally transferring k fclin, f msr Qclin,Qmsr values from the SFD to unknown diodes was tested by comparing the experimentally transferred k fclin, f msr Qclin,Qmsr values for unmodified PTWe and EDGEe diodes to Monte Carlo simulated values. Results 1.0 mm of air was required to make the PTWe diode correction-free. This modified diode (PTWeair) produced output factors equivalent to those in water at all field sizes (5–50 mm). The optimal air thickness required for the EDGEe diode was found to be 0.6 mm. The modified diode (EDGEeair) produced output factors equivalent to those in water, except at field sizes of 8 and 10 mm where it measured approximately 2% greater than the relative dose to water. The experimentally calculated k fclin, f msr Qclin,Qmsr for both the PTWe and the EDGEe diodes (without air) matched Monte Carlo simulated results, thus proving that it is feasible to transfer k fclin, f msr Qclin,Qmsr from one commercially available detector to another using experimental methods and the recommended experimental setup. Conclusions It is possible to create a diode which does not require corrections for small field output factor measurements. This has been performed and verified experimentally. The ability of a detector to be “correction-free” depends strongly on its design and composition. A nonwater-equivalent detector can only be “correction-free” if competing perturbations of the beam cancel out at all field sizes. This should not be confused with true water equivalency of a detector.
Resumo:
Devising authentic assessments for subjects with large enrolments is a challenge. This study describes an electronic role-play assessment for approximately 600 first-year nursing students to learn and apply pathophysiology (bioscience) concepts to nursing practice. Students used Microsoft Office PowerPoint® to prepare electronic role-plays both between a nurse and patient, and between two nurses, thus simulating workplace scenarios. Student feedback demonstrated that respondents found this assessment useful for learning pathophysiology, and for applying pathophysiology to a nursing clinical setting. This electronic presentation circumvented issues associated with a traditional oral presentation such as embarrassment and logistics of scheduling groups, and rated well with students of non-English speaking background. The electronic role-play assessment initiative encouraged students to apply their bioscience knowledge to a clinical setting, and allowed students to conceptualise the importance of bioscience within both the nursing degree and the profession.
Resumo:
The growth of graphene by chemical vapor deposition on metal foils is a promising technique to deliver large-area films with high electron mobility. Nowadays, the chemical vapor deposition of hydrocarbons on copper is the most investigated synthesis method, although many other carbon precursors and metal substrates are used too. Among these, ethanol is a safe and inexpensive precursor that seems to offer favorable synthesis kinetics. We explored the growth of graphene on copper from ethanol, focusing on processes of short duration (up to one min). We investigated the produced films by electron microscopy, Raman and X-ray photoemission spectroscopy. A graphene film with high crystalline quality was found to cover the entire copper catalyst substrate in just 20 s, making ethanol appear as a more efficient carbon feedstock than methane and other commonly used precursors.
Resumo:
Objectives Commercial sex is licensed in Victoria, Australia such that sex workers are required to have regular tests for sexually transmitted infections (STIs). However, the incidence and prevalence of STIs in sex workers are very low, especially since there is almost universal condom use at work. We aimed to conduct a cost-effectiveness analysis of the financial cost of the testing policy versus the health benefits of averting the transmission of HIV, syphilis, chlamydia and gonorrhoea to clients. Methods We developed a simple mathematical transmission model, informed by conservative parameter estimates from all available data, linked to a cost-effectiveness analysis. Results We estimated that under current testing rates, it costs over $A90 000 in screening costs for every chlamydia infection averted (and $A600 000 in screening costs for each quality-adjusted life year (QALY) saved) and over $A4 000 000 for every HIV infection averted ($A10 000 000 in screening costs for each QALY saved). At an assumed willingness to pay of $A50 000 per QALY gained, HIV testing should not be conducted less than approximately every 40 weeks and chlamydia testing approximately once per year; in comparison, current requirements are testing every 12 weeks for HIV and every 4 weeks for chlamydia. Conclusions Mandatory screening of female sex workers at current testing frequencies is not cost-effective for the prevention of disease in their male clients. The current testing rate required of sex workers in Victoria is excessive. Screening intervals for sex workers should be based on local STI epidemiology and not locked by legislation.
Resumo:
Human saliva mirrors body’s health and well-being and many of the biomolecules present in blood or urine can also be found in salivary secretions. However, biomolecular concentrations in saliva are usually one tenth to one thousandth of the levels in blood (Pfaffe et al., 2011). Sensitive detection technology platforms are therefore required to detect biomolecules in saliva. Another road block to the advancement of salivary diagnostics is the lack of information related to healthy state saliva vs. a diseased saliva, baseline levels and reference ranges and diurnal variations. Saliva has numerous advantages over blood or urine as a diagnostic fluid: (a) the non-invasive nature of sample collection and the simple, safe, painless and cost-effective methods to collect it; (b) unskilled personnel can collect saliva samples at multiple time points; and (c) the total protein concentration is approximately a quarter of that is present in plasma, which makes it easier to investigate low abundance proteins (Pfaffe et al., 2011). Currently, saliva assays are routinely used to determine, diseases such as HIV, drugs and substances of abuse to provide information on exposure and give qualitative information on the type of illicit drug used (Kintz et al., 2009), cortisol levels for diagnosing Cushing’s syndrome (Doi et al., 2008), and use for biomonitoring of exposure to chemicals (Caporossi et al., 2010) to measure hormones (Gröschl, 2009)....