998 resultados para Asymptotic Methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Singular Value Decomposition (SVD), Principal Component Analysis (PCA) and Multiple Linear Regression (MLR) are some of the mathematical pre- liminaries that are discussed prior to explaining PLS and PCR models. Both PLS and PCR are applied to real spectral data and their di erences and similarities are discussed in this thesis. The challenge lies in establishing the optimum number of components to be included in either of the models but this has been overcome by using various diagnostic tools suggested in this thesis. Correspondence analysis (CA) and PLS were applied to ecological data. The idea of CA was to correlate the macrophytes species and lakes. The di erences between PLS model for ecological data and PLS for spectral data are noted and explained in this thesis. i

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computational model-based simulation methods were developed for the modelling of bioaffinity assays. Bioaffinity-based methods are widely used to quantify a biological substance in biological research, development and in routine clinical in vitro diagnostics. Bioaffinity assays are based on the high affinity and structural specificity between the binding biomolecules. The simulation methods developed are based on the mechanistic assay model, which relies on the chemical reaction kinetics and describes the forming of a bound component as a function of time from the initial binding interaction. The simulation methods were focused on studying the behaviour and the reliability of bioaffinity assay and the possibilities the modelling methods of binding reaction kinetics provide, such as predicting assay results even before the binding reaction has reached equilibrium. For example, a rapid quantitative result from a clinical bioaffinity assay sample can be very significant, e.g. even the smallest elevation of a heart muscle marker reveals a cardiac injury. The simulation methods were used to identify critical error factors in rapid bioaffinity assays. A new kinetic calibration method was developed to calibrate a measurement system by kinetic measurement data utilizing only one standard concentration. A nodebased method was developed to model multi-component binding reactions, which have been a challenge to traditional numerical methods. The node-method was also used to model protein adsorption as an example of nonspecific binding of biomolecules. These methods have been compared with the experimental data from practice and can be utilized in in vitro diagnostics, drug discovery and in medical imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Frequency converters are widely used in the industry to enable better controllability and efficiency of variable speed AC motor drives. Despite these advantages, certain challenges concerning the inverter and motor interfacing have been present for decades. As insulated gate bipolar transistors entered the market, the inverter output voltage transition rate significantly increased compared with their predecessors. Inverters operate based on pulse width modulation of the output voltage, and the steep voltage edge fed by the inverter produces a motor terminal overvoltage. The overvoltage causes extra stress to the motor insulation, which may lead to a prematuremotor failure. The overvoltage is not generated by the inverter alone, but also by the sum effect of the motor cable length and the impedance mismatch between the cable and the motor. Many solutions have been shown to limit the overvoltage, and the mainstream products focus on passive filters. This doctoral thesis studies an alternative methodology for motor overvoltage reduction. The focus is on minimization of the passive filter dimensions, physical and electrical, or better yet, on operation without any filter. This is achieved by additional inverter control and modulation. The studied methods are implemented on different inverter topologies, varying in nominal voltage and current.For two-level inverters, the studied method is termed active du/dt. It consists of a small output LC filter, which is controlled by an independent modulator. The overvoltage is limited by a reduced voltage transition rate. For multilevel inverters, an overvoltage mitigation method operating without a passive filter, called edge modulation, is implemented. The method uses the capability of the inverter to produce two switching operations in the same direction to cancel the oscillating voltages of opposite phases. For parallel inverters, two methods are studied. They are both intended for two-level inverters, but the first uses individual motor cables from each inverter while the other topology applies output inductors. The overvoltage is reduced by interleaving the switching operations to produce a similar oscillation accumulation as with the edge modulation. The implementation of these methods is discussed in detail, and the necessary modifications to the control system of the inverter are presented. Each method is experimentally verified by operating industrial frequency converters with the modified control. All the methods are found feasible, and they provide sufficient overvoltage protection. The limitations and challenges brought about by the methods are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knowledge of the behaviour of cellulose, hemicelluloses, and lignin during wood and pulp processing is essential for understanding and controlling the processes. Determination of monosaccharide composition gives information about the structural polysaccharide composition of wood material and helps when determining the quality of fibrous products. In addition, monitoring of the acidic degradation products gives information of the extent of degradation of lignin and polysaccharides. This work describes two capillary electrophoretic methods developed for the analysis of monosaccharides and for the determination of aliphatic carboxylic acids from alkaline oxidation solutions of lignin and wood. Capillary electrophoresis (CE), in its many variants is an alternative separation technique to chromatographic methods. In capillary zone electrophoresis (CZE) the fused silica capillary is filled with an electrolyte solution. An applied voltage generates a field across the capillary. The movement of the ions under electric field is based on the charge and hydrodynamic radius of ions. Carbohydrates contain hydroxyl groups that are ionised only in strongly alkaline conditions. After ionisation, the structures are suitable for electrophoretic analysis and identification through either indirect UV detection or electrochemical detection. The current work presents a new capillary zone electrophoretic method, relying on in-capillary reaction and direct UV detection at the wavelength of 270 nm. The method has been used for the simultaneous separation of neutral carbohydrates, including mono- and disaccharides and sugar alcohols. The in-capillary reaction produces negatively charged and UV-absorbing compounds. The optimised method was applied to real samples. The methodology is fast since no other sample preparation, except dilution, is required. A new method for aliphatic carboxylic acids in highly alkaline process liquids was developed. The goal was to develop a method for the simultaneous analysis of the dicarboxylic acids, hydroxy acids and volatile acids that are oxidation and degradation products of lignin and wood polysaccharides. The CZE method was applied to three process cases. First, the fate of lignin under alkaline oxidation conditions was monitored by determining the level of carboxylic acids from process solutions. In the second application, the degradation of spruce wood using alkaline and catalysed alkaline oxidation were compared by determining carboxylic acids from the process solutions. In addition, the effectiveness of membrane filtration and preparative liquid chromatography in the enrichment of hydroxy acids from black liquor was evaluated, by analysing the effluents with capillary electrophoresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid ongoing evolution of multiprocessors will lead to systems with hundreds of processing cores integrated in a single chip. An emerging challenge is the implementation of reliable and efficient interconnection between these cores as well as other components in the systems. Network-on-Chip is an interconnection approach which is intended to solve the performance bottleneck caused by traditional, poorly scalable communication structures such as buses. However, a large on-chip network involves issues related to congestion problems and system control, for instance. Additionally, faults can cause problems in multiprocessor systems. These faults can be transient faults, permanent manufacturing faults, or they can appear due to aging. To solve the emerging traffic management, controllability issues and to maintain system operation regardless of faults a monitoring system is needed. The monitoring system should be dynamically applicable to various purposes and it should fully cover the system under observation. In a large multiprocessor the distances between components can be relatively long. Therefore, the system should be designed so that the amount of energy-inefficient long-distance communication is minimized. This thesis presents a dynamically clustered distributed monitoring structure. The monitoring is distributed so that no centralized control is required for basic tasks such as traffic management and task mapping. To enable extensive analysis of different Network-on-Chip architectures, an in-house SystemC based simulation environment was implemented. It allows transaction level analysis without time consuming circuit level implementations during early design phases of novel architectures and features. The presented analysis shows that the dynamically clustered monitoring structure can be efficiently utilized for traffic management in faulty and congested Network-on-Chip-based multiprocessor systems. The monitoring structure can be also successfully applied for task mapping purposes. Furthermore, the analysis shows that the presented in-house simulation environment is flexible and practical tool for extensive Network-on-Chip architecture analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this thesis is twofold. The first and major part is devoted to sensitivity analysis of various discrete optimization problems while the second part addresses methods applied for calculating measures of solution stability and solving multicriteria discrete optimization problems. Despite numerous approaches to stability analysis of discrete optimization problems two major directions can be single out: quantitative and qualitative. Qualitative sensitivity analysis is conducted for multicriteria discrete optimization problems with minisum, minimax and minimin partial criteria. The main results obtained here are necessary and sufficient conditions for different stability types of optimal solutions (or a set of optimal solutions) of the considered problems. Within the framework of quantitative direction various measures of solution stability are investigated. A formula for a quantitative characteristic called stability radius is obtained for the generalized equilibrium situation invariant to changes of game parameters in the case of the H¨older metric. Quality of the problem solution can also be described in terms of robustness analysis. In this work the concepts of accuracy and robustness tolerances are presented for a strategic game with a finite number of players where initial coefficients (costs) of linear payoff functions are subject to perturbations. Investigation of stability radius also aims to devise methods for its calculation. A new metaheuristic approach is derived for calculation of stability radius of an optimal solution to the shortest path problem. The main advantage of the developed method is that it can be potentially applicable for calculating stability radii of NP-hard problems. The last chapter of the thesis focuses on deriving innovative methods based on interactive optimization approach for solving multicriteria combinatorial optimization problems. The key idea of the proposed approach is to utilize a parameterized achievement scalarizing function for solution calculation and to direct interactive procedure by changing weighting coefficients of this function. In order to illustrate the introduced ideas a decision making process is simulated for three objective median location problem. The concepts, models, and ideas collected and analyzed in this thesis create a good and relevant grounds for developing more complicated and integrated models of postoptimal analysis and solving the most computationally challenging problems related to it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To obtain the desirable accuracy of a robot, there are two techniques available. The first option would be to make the robot match the nominal mathematic model. In other words, the manufacturing and assembling tolerances of every part would be extremely tight so that all of the various parameters would match the “design” or “nominal” values as closely as possible. This method can satisfy most of the accuracy requirements, but the cost would increase dramatically as the accuracy requirement increases. Alternatively, a more cost-effective solution is to build a manipulator with relaxed manufacturing and assembling tolerances. By modifying the mathematical model in the controller, the actual errors of the robot can be compensated. This is the essence of robot calibration. Simply put, robot calibration is the process of defining an appropriate error model and then identifying the various parameter errors that make the error model match the robot as closely as possible. This work focuses on kinematic calibration of a 10 degree-of-freedom (DOF) redundant serial-parallel hybrid robot. The robot consists of a 4-DOF serial mechanism and a 6-DOF hexapod parallel manipulator. The redundant 4-DOF serial structure is used to enlarge workspace and the 6-DOF hexapod manipulator is used to provide high load capabilities and stiffness for the whole structure. The main objective of the study is to develop a suitable calibration method to improve the accuracy of the redundant serial-parallel hybrid robot. To this end, a Denavit–Hartenberg (DH) hybrid error model and a Product-of-Exponential (POE) error model are developed for error modeling of the proposed robot. Furthermore, two kinds of global optimization methods, i.e. the differential-evolution (DE) algorithm and the Markov Chain Monte Carlo (MCMC) algorithm, are employed to identify the parameter errors of the derived error model. A measurement method based on a 3-2-1 wire-based pose estimation system is proposed and implemented in a Solidworks environment to simulate the real experimental validations. Numerical simulations and Solidworks prototype-model validations are carried out on the hybrid robot to verify the effectiveness, accuracy and robustness of the calibration algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ocelot (Leopardus pardalis) is included in list of wild felid species protected by CITES and is part of conservation strategies that necessarily involve the use of assisted reproduction techniques, which requires practical and minimally invasive techniques of high reproducibility that permit the study of animal reproductive physiology. The objective of this study was to compare and validate two commercial assays: ImmuChem Double Antibody Corticosterone 125I RIA from ICN Biomedicals, Costa Mesa, CA, USA; and Coat-a-Count Cortisol 125I RIA from DPC, Los Angeles, CA, USA, for assessment of fecal glucocorticoid metabolites in ocelots submitted to ACTH (adrenocorticotropic hormone) challenge. Fecal samples were collected from five ocelots kept at the Brazilian Center of Neotropical Felines, Associação Mata Ciliar, São Paulo, Brazil, and one of the animals was chosen as a negative control. The experiment was conducted over a period of 9 days. On day 0, a total dose of 100 IU ACTH was administered intramuscularly. Immediately after collection the samples were stored at 20C in labeled plastic bags. The hormone metabolites were subsequently extracted and assayed using the two commercial kits. Previously it was performed a trial with the DPC kit to check the best extraction method for hormones metabolites. Data were analyzed with the SAS program for Windows V8 and reported as means ± SEM. The Schwarzenberger extraction method was slightly better when compared with the Wasser extraction method (103,334.56 ± 19,010.37ng/g of wet feces and 59,223.61 ± 12,725.36ng/g of wet feces respectively; P=0,0657). The ICN kit detected an increase in glucocorticoid metabolite concentrations in a more reliable manner. Metabolite concentrations (ng/g wet feces) on day 0 and day 1 were 66,956.28 ± 36,786.93 and 92,991.19 ± 28,555.63 for the DPC kit, and 205,483.32 ± 83,811.32 and 814,578.75 ± 292,150.47 for the ICN kit, respectively. The limit of detection for the ICN kit was 7.7 ng/mL for 100% B/Bo (25ng/mL for 88%B/Bo) and for the DPC kit it was 0.2ug/dL for 90.95% B/Bo (1ug/dL for 81.27% B/Bo). In conclusion it was confirmed that the Schwarzenberger extraction method and the ICN kit are superior for extracting and measuring fecal glucocorticoid metabolites in ocelot fecal samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During a possible loss of coolant accident in BWRs, a large amount of steam will be released from the reactor pressure vessel to the suppression pool. Steam will be condensed into the suppression pool causing dynamic and structural loads to the pool. The formation and break up of bubbles can be measured by visual observation using a suitable pattern recognition algorithm. The aim of this study was to improve the preliminary pattern recognition algorithm, developed by Vesa Tanskanen in his doctoral dissertation, by using MATLAB. Video material from the PPOOLEX test facility, recorded during thermal stratification and mixing experiments, was used as a reference in the development of the algorithm. The developed algorithm consists of two parts: the pattern recognition of the bubbles and the analysis of recognized bubble images. The bubble recognition works well, but some errors will appear due to the complex structure of the pool. The results of the image analysis were reasonable. The volume and the surface area of the bubbles were not evaluated. Chugging frequencies calculated by using FFT fitted well into the results of oscillation frequencies measured in the experiments. The pattern recognition algorithm works in the conditions it is designed for. If the measurement configuration will be changed, some modifications have to be done. Numerous improvements are proposed for the future 3D equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of faecal glucocorticoid metabolites provides a powerful noninvasive tool for monitoring adrenocortical activity in wild animals. However, differences regarding the metabolism and excretion of these substances make a validation for each species and sex investigated obligatory. Although maned wolves (Chrysocyon brachyurus) are the biggest canids in South America, their behaviour and physiology are poorly known and they are at risk in the wild. Two methods for measuring glucocorticoid metabolites in maned wolves were validated: a radio- and an enzyme immunoassay. An ACTH challenge was used to demonstrate that changes in adrenal function are reflected in faecal glucocorticoid metabolites. Our results suggest that both methods enable a reliable assessment of stress hormones in maned wolves avoiding short-term rises in glucocorticoid concentrations due to handling and restraint. These methods can be used as a valuable tool in studies of stress and conservation in this wild species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple sclerosis (MS) is a chronic immune-mediated inflammatory disorder of the central nervous system. MS is the most common disabling central nervous system (CNS) disease of young adults in the Western world. In Finland, the prevalence of MS ranges between 1/1000 and 2/1000 in different areas. Fabry disease (FD) is a rare hereditary metabolic disease due to mutation in a single gene coding α-galactosidase A (alpha-gal A) enzyme. It leads to multi-organ pathology, including cerebrovascular disease. Currently there are 44 patients with diagnosed FD in Finland. Magnetic resonance imaging (MRI) is commonly used in the diagnostics and follow-up of these diseases. The disease activity can be demonstrated by occurrence of new or Gadolinium (Gd)-enhancing lesions in routine studies. Diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) are advanced MR sequences which can reveal pathologies in brain regions which appear normal on conventional MR images in several CNS diseases. The main focus in this study was to reveal whether whole brain apparent diffusion coefficient (ADC) analysis can be used to demonstrate MS disease activity. MS patients were investigated before and after delivery and before and after initiation of diseasemodifying treatment (DMT). In FD, DTI was used to reveal possible microstructural alterations at early timepoints when excessive signs of cerebrovascular disease are not yet visible in conventional MR sequences. Our clinical and MRI findings at 1.5T indicated that post-partum activation of the disease is an early and common phenomenon amongst mothers with MS. MRI seems to be a more sensitive method for assessing MS disease activity than the recording of relapses. However, whole brain ADC histogram analysis is of limited value in the follow-up of inflammatory conditions in a pregnancy-related setting because the pregnancy-related physiological effects on ADC overwhelm the alterations in ADC associated with MS pathology in brain tissue areas which appear normal on conventional MRI sequences. DTI reveals signs of microstructural damage in brain white matter of FD patients before excessive white matter lesion load can be observed on conventional MR scans. DTI could offer a valuable tool for monitoring the possible effects of enzyme replacement therapy in FD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of tear sampling for protein quantification. Tear samples were collected from 29 healthy dogs (58 eyes) using Schirmer tear test (STT) strip and microcapillary tubes. The samples were frozen at -80ºC and analyzed by the Bradford method. Results were analyzed by Student's t test. The average protein concentration and standard deviation from tears collected with microcapillary tube were 4.45mg/mL ±0.35 and 4,52mg/mL ±0.29 for right and left eyes respectively. The average protein concentration and standard deviation from tears collected with Schirmer Tear Test (STT) strip were and 54.5mg/mL ±0.63 and 54.15mg/mL ±0.65 to right and left eyes respectively. Statistically significant differences (p<0.001) were found between the methods. In the conditions in which this study was conducted, the average protein concentration obtained with the Bradford test from tear samples obtained by Schirmer Tear Test (STT) strip showed values higher than those obtained with microcapillary tube. It is important that concentration of tear protein pattern values should be analyzed according the method used to collect tear samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Identification of Escherichia coli requires knowledge regarding the prevalent serotypes and virulence factors profiles allows the classification in pathogenic/non-pathogenic. However, some of these bacteria do not express flagellar antigen invitro. In this case the PCR-restriction fragment length polymorphism (RFLP-PCR) and sequencing of the fliC may be suitable for the identification of antigens by replacing the traditional serology. We studied 17 samples of E. coli isolated from animals and presenting antigen H nontypeable (HNT). The H antigens were characterized by PCR-RFLP and sequencing of fliC gene. Three new flagellin genes were identified, for which specific antisera were obtained. The PCR-RFLP was shown to be faster than the serotyping H antigen in E. coli, provided information on some characteristics of these antigens and indicated the presence of new genes fliC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this experiment, methods of total fecal collection (TFC) and internal markers (acid-insoluble ash - AIA, crude fiber - CF, and acid-detergent fiber - ADF) were compared for determination of the coefficients of apparent digestibility (CAD) for dry matter (DM), crude protein (CP), ether extract (EE), nitrogen-free extracts (NFE), and gross energy (GE) of commercial feline dry kibble for ocelots (Leopardus pardalis). Six adult animals, weighing 12.45±1.37 kg, gradually received experimental kibble in their usual diet until the beginning of the experiment and were submitted to an adaptation period ten days prior to the collection period. CAD obtained by TFC, AIA, CF, and ADF were, respectively, 73.7, 76.83, 62.01, and 46.03% for dry matter; 81.9, 84.8, 75.8, and 63.8% for crude protein; 85, 86.7, 78.5, and 69.1% for ether extract; 78.52, 79.55, 69.11, and 53.04% for nitrogen-free extracts; and 80.5, 82.2, 71.4, and 58.4% for gross energy. The AIA method showed to be efficient in determining coefficients of apparent digestibility and may contribute to investigations on the digestibility of diets for wild felines. In comparison to the items of ocelot's usual diet, the kibble used in this paper provided an adequate nutritional supply with reduced daily costs per animal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tarkoituksena oli kehittää analyyttinen erotusmenetelmä eräässä valmistusprosessissa käytettävän hapettavan aineen ja liuottimen välillä syntyvien reaktiotuotteiden tutkimiseen ja analysoimiseen. Lisäksi tarkoituksena oli tutkia prosessiolosuhteiden turvallisuutta. Kirjallisuusosassa käsitellään erilaisia orgaanisia peroksideja, niiden käyttötarkoituksia ja niiden käyttöön liittyviä huomioitavia asioita. Lisäksi tarkastellaan yleisimpiä analyysimenetelmiä, joita on käytetty erilaisten peroksidien analysoinnissa. Näitä analyysimenetelmiä on useimmiten käytetty nestemäisten näytteiden tutkimuksissa. Harvemmin on analysoitu kaasu- ja kiintoainenäytteitä. Kokeellisessa osassa kehitettiin kirjallisuuden perusteella peroksidiyhdisteille identifiointimenetelmä ja tutkittiin prosessin näytteet. Analyysimenetelmiksi valittiin iodometrinen titraus ja HPLC-UV-MS-menetelmä. Lisäksi käytettiin peroksidimittaukseen soveltuvia testiliuskoja. Tutkimus osoitti, että iodometrisen titrauksen ja testiliuskojen perusteella näytteissä oli vähäisiä määriä peroksideja viikon jälkeen peroksidilisäyksestä. HPLC-UV-MS-analyysien perusteella näytteiden analysointia häiritsi selluloosa, jota löytyi jokaisesta näytteestä.