999 resultados para . neutron radiation field


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBreast cancer is one of the most common cancers affecting one in eight women during their lives. Survival rates have increased steadily thanks to early diagnosis with mammography screening and more efficient treatment strategies. Post-operative radiation therapy is a standard of care in the management of breast cancer and has been shown to reduce efficiently both local recurrence rate and breast cancer mortality. Radiation therapy is however associated with some late effects for long-term survivors. Radiation-induced secondary cancer is a relatively rare but severe late effect of radiation therapy. Currently, radiotherapy plans are essentially optimized to maximize tumor control and minimize late deterministic effects (tissue reactions) that are mainly associated with high doses (» 1 Gy). With improved cure rates and new radiation therapy technologies, it is also important to evaluate and minimize secondary cancer risks for different treatment techniques. This is a particularly challenging task due to the large uncertainties in the dose-response relationship.In contrast with late deterministic effects, secondary cancers may be associated with much lower doses and therefore out-of-field doses (also called peripheral doses) that are typically inferior to 1 Gy need to be determined accurately. Out-of-field doses result from patient scatter and head scatter from the treatment unit. These doses are particularly challenging to compute and we characterized it by Monte Carlo (MC) calculation. A detailed MC model of the Siemens Primus linear accelerator has been thoroughly validated with measurements. We investigated the accuracy of such a model for retrospective dosimetry in epidemiological studies on secondary cancers. Considering that patients in such large studies could be treated on a variety of machines, we assessed the uncertainty in reconstructed peripheral dose due to the variability of peripheral dose among various linac geometries. For large open fields (> 10x10 cm2), the uncertainty would be less than 50%, but for small fields and wedged fields the uncertainty in reconstructed dose could rise up to a factor of 10. It was concluded that such a model could be used for conventional treatments using large open fields only.The MC model of the Siemens Primus linac was then used to compare out-of-field doses for different treatment techniques in a female whole-body CT-based phantom. Current techniques such as conformai wedged-based radiotherapy and hybrid IMRT were investigated and compared to older two-dimensional radiotherapy techniques. MC doses were also compared to those of a commercial Treatment Planning System (TPS). While the TPS is routinely used to determine the dose to the contralateral breast and the ipsilateral lung which are mostly out of the treatment fields, we have shown that these doses may be highly inaccurate depending on the treatment technique investigated. MC shows that hybrid IMRT is dosimetrically similar to three-dimensional wedge-based radiotherapy within the field, but offers substantially reduced doses to out-of-field healthy organs.Finally, many different approaches to risk estimations extracted from the literature were applied to the calculated MC dose distribution. Absolute risks varied substantially as did the ratio of risk between two treatment techniques, reflecting the large uncertainties involved with current risk models. Despite all these uncertainties, the hybrid IMRT investigated resulted in systematically lower cancer risks than any of the other treatment techniques. More epidemiological studies with accurate dosimetry are required in the future to construct robust risk models. In the meantime, any treatment strategy that reduces out-of-field doses to healthy organs should be investigated. Electron radiotherapy might offer interesting possibilities with this regard.RésuméLe cancer du sein affecte une femme sur huit au cours de sa vie. Grâce au dépistage précoce et à des thérapies de plus en plus efficaces, le taux de guérison a augmenté au cours du temps. La radiothérapie postopératoire joue un rôle important dans le traitement du cancer du sein en réduisant le taux de récidive et la mortalité. Malheureusement, la radiothérapie peut aussi induire des toxicités tardives chez les patients guéris. En particulier, les cancers secondaires radio-induits sont une complication rare mais sévère de la radiothérapie. En routine clinique, les plans de radiothérapie sont essentiellement optimisées pour un contrôle local le plus élevé possible tout en minimisant les réactions tissulaires tardives qui sont essentiellement associées avec des hautes doses (» 1 Gy). Toutefois, avec l'introduction de différentes nouvelles techniques et avec l'augmentation des taux de survie, il devient impératif d'évaluer et de minimiser les risques de cancer secondaire pour différentes techniques de traitement. Une telle évaluation du risque est une tâche ardue étant donné les nombreuses incertitudes liées à la relation dose-risque.Contrairement aux effets tissulaires, les cancers secondaires peuvent aussi être induits par des basses doses dans des organes qui se trouvent hors des champs d'irradiation. Ces organes reçoivent des doses périphériques typiquement inférieures à 1 Gy qui résultent du diffusé du patient et du diffusé de l'accélérateur. Ces doses sont difficiles à calculer précisément, mais les algorithmes Monte Carlo (MC) permettent de les estimer avec une bonne précision. Un modèle MC détaillé de l'accélérateur Primus de Siemens a été élaboré et validé avec des mesures. La précision de ce modèle a également été déterminée pour la reconstruction de dose en épidémiologie. Si on considère que les patients inclus dans de larges cohortes sont traités sur une variété de machines, l'incertitude dans la reconstruction de dose périphérique a été étudiée en fonction de la variabilité de la dose périphérique pour différents types d'accélérateurs. Pour de grands champs (> 10x10 cm ), l'incertitude est inférieure à 50%, mais pour de petits champs et des champs filtrés, l'incertitude de la dose peut monter jusqu'à un facteur 10. En conclusion, un tel modèle ne peut être utilisé que pour les traitements conventionnels utilisant des grands champs.Le modèle MC de l'accélérateur Primus a été utilisé ensuite pour déterminer la dose périphérique pour différentes techniques dans un fantôme corps entier basé sur des coupes CT d'une patiente. Les techniques actuelles utilisant des champs filtrés ou encore l'IMRT hybride ont été étudiées et comparées par rapport aux techniques plus anciennes. Les doses calculées par MC ont été comparées à celles obtenues d'un logiciel de planification commercial (TPS). Alors que le TPS est utilisé en routine pour déterminer la dose au sein contralatéral et au poumon ipsilatéral qui sont principalement hors des faisceaux, nous avons montré que ces doses peuvent être plus ou moins précises selon la technTque étudiée. Les calculs MC montrent que la technique IMRT est dosimétriquement équivalente à celle basée sur des champs filtrés à l'intérieur des champs de traitement, mais offre une réduction importante de la dose aux organes périphériques.Finalement différents modèles de risque ont été étudiés sur la base des distributions de dose calculées par MC. Les risques absolus et le rapport des risques entre deux techniques de traitement varient grandement, ce qui reflète les grandes incertitudes liées aux différents modèles de risque. Malgré ces incertitudes, on a pu montrer que la technique IMRT offrait une réduction du risque systématique par rapport aux autres techniques. En attendant des données épidémiologiques supplémentaires sur la relation dose-risque, toute technique offrant une réduction des doses périphériques aux organes sains mérite d'être étudiée. La radiothérapie avec des électrons offre à ce titre des possibilités intéressantes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy is a widely used treatment option in cancer. However, recent evidence suggests that doses of ionizing radiation (IR) delivered inside the tumor target volume, during fractionated radiotherapy, can promote tumor invasion and metastasis. Furthermore, the tissues that surround the tumor area are also exposed to low doses of IR that are lower than those delivered inside the tumor mass, because external radiotherapy is delivered to the tumor through multiple radiation beams, in order to prevent damage of organs at risk. The biological effects of these low doses of IR on the healthy tissue surrounding the tumor area, and in particular on the vasculature remain largely to be determined. We found that doses of IR lower or equal to 0.8 Gy enhance endothelial cell migration without impinging on cell proliferation or survival. Moreover, we show that low-dose IR induces a rapid phosphorylation of several endothelial cell proteins, including the Vascular Endothelial Growth Factor (VEGF) Receptor-2 and induces VEGF production in hypoxia mimicking conditions. By activating the VEGF Receptor-2, low-dose IR enhances endothelial cell migration and prevents endothelial cell death promoted by an anti-angiogenic drug, bevacizumab. In addition, we observed that low-dose IR accelerates embryonic angiogenic sprouting during zebrafish development and promotes adult angiogenesis during zebrafish fin regeneration and in the murine Matrigel assay. Using murine experimental models of leukemia and orthotopic breast cancer, we show that low-dose IR promotes tumor growth and metastasis and that these effects were prevented by the administration of a VEGF receptor-tyrosine kinase inhibitor immediately before IR exposure. These findings demonstrate a new mechanism to the understanding of the potential pro-metastatic effect of IR and may provide a new rationale basis to the improvement of current radiotherapy protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monoclonal antibodies (mAbs) and human sera from gametocyte carriers were applied in the bio-assay to test for their transmission-blocking capacity. Competition ELISA's have been developed for the detection of natural transmission blocking antibodies. Approximately 55 of the sera blocking in the bio-assay gave positive results in these competition ELISA's.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Vegeu el resum a l'inici del document del fitxer adjunt."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the feasibility and efficacy of subcutaneous amifostine therapy in patients with head and neck cancer treated with curative accelerated radiotherapy (RT). DESIGN: Retrospective study. SETTING: University of Lausanne, Lausanne, Switzerland. PATIENTS: Thirty-three consecutive patients (male-female ratio, 4.5; median age, 54 years [age range, 39-76 years]). INTERVENTIONS: Between November 2000 and January 2003, the 33 patients were treated with curative definitive (n = 19) or postoperative (n = 14) RT with (n = 26) or without (n = 7) chemotherapy. All patients received conformal RT. Fractionation schedule consisted of concomitant-boost (Friday afternoon session) accelerated RT using 70 Gy (2 Gy per fraction) in 6 weeks in patients treated with definitive RT and 66 Gy (2 Gy per fraction) in 5 weeks and 3 days in the postoperative setting. Parotid glands received at least 50 Gy in all patients. Amifostine was administered to a total dose of 500 mg subcutaneously, 15 to 30 minutes before morning RT sessions. RESULTS: All patients received their planned treatment (including chemotherapy). Ten patients received the full schedule of amifostine (at least 25 injections), 9 received 20 to 24 doses, 4 received 10 to 19 doses, 5 received 5 to 9 doses, and 5 received fewer than 5 doses. Fifteen patients (45%) did not show any intolerance related to amifostine use. Amifostine therapy was discontinued because of nausea in 11 patients (33%) and hypotension in 6 patients (18%), and 1 patient refused treatment. No grade 3, amifostine-related, cutaneous toxic effects were observed. Radiotherapy-induced grade 3 acute toxic effects included mucositis in 14 patients (42%), erythema in 14 patients (42%), and dysphagia in 13 patients (39%). Late toxic effects included grade 2 or more xerostomia in 17 patients (51%) and fibrosis in 3 patients (9%). Grade 2 or more xerostomia was observed in 8 (42%) of 19 patients receiving 20 injections or more vs 9 (64%) of 14 patients receiving fewer than 20 injections (P = .15). CONCLUSIONS: Subcutaneous amifostine administration in combination with accelerated concomitant-boost RT with or without chemotherapy is feasible. The major adverse effect of subcutaneous administration was nausea despite prophylactic antiemetic medication, and hypotension was observed in only 6 patients (18%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsed-field gel electrophoresis (PFGE) is widely used for epidemic investigations of methicillin-resistant Staphylococcus aureus (MRSA). In the present study, we evaluated its use in a long-term epidemiological setting (years to few decades, country to continent level). The clustering obtained from PFGE patterns after SmaI digestion of the DNA of 20 strains was compared to that obtained using a phylogenetic typing method (multiprimer RAPD). The results showed that the analysis of small PFGE bands (10-85kb) correlates better with multiprimer RAPD than the analysis of large PFGE bands (>85-700kb), suggesting that the analysis of small bands would be more suitable for the investigation of long-term epidemiological setting. However, given the technical difficulties to obtain a good resolution of these bands and the putative presence of plasmids among them, PFGE does not appear to be a method of choice for the long-term epidemiology analysis of MRSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extent of genomic variability of clones of Schistosoma mansoni obtained from field isolates was compared with that of strains that have been laboratory maintained. Analysis was undertaken using randomly amplified polymorphic dNAs (RAPDs) generated with three primers. Phenograms showing the similarity among the clones were constructed. The data showed that while the laboratory strain is highly homogeneous the clones derived from the field populations were highly variable with 43% of RAPDs exhibiting polymorphisms among 23 clones. Clones isolated from the same infected individual were always more closely grouped than clones from different individuals. The data clearly demonstrated that earlier analyses of the genomic variability in S. mansoni have underestimated this phenomenon due to the failure to examine field isolates

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Dynamic high-field magnetic resonance (MR) defecography including the evacuation phase is a promising tool for the assessment of functional pelvic disorders, nowadays seen with increasing frequency in elderly women in particular. Learning objectives: 1. To describe the adequate technique of dynamic high-field MRI (3T) in assessing pelvic floor disorders. 2. To provide an overview of the most common pathologies occurring during the evacuation phase, especially in comparison with results of conventional defecography. Methods and materials: After description of the ideal technical parameters of MR defecography performed in supine position after gel rectal filling with a 3 Tesla unit and including the evacuation phase we stress the importance of using a standardized evaluation system for the exact assessment of pelvic floor pathophysiology. Results: The typical pelvic floor disorders occurring before and/or during the evacuation phase, such as sphincter insufficiency, vaginal vault and/or uterine prolapse, cystourethrocele, peritoneo-/ entero-/ sigmoïdocele or rectal prolapse, are demonstrated. The difference between the terms "pelvic floor descent" and "pelvic floor relaxation" are pictorially outlined. MR results are compared with these of conventional defecography. Conclusion: Exact knowledge about the correct technique including the evacuation phase and the use of a standardized evaluation system in assessing pelvic floor disorders by dynamic high-field MRI is mandatory for accurate and reproducible diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A population of 420 snails Biomphalaria straminea, an intermediate host of Schistosoma mansoni, received gamma-rays obtained from a 60Co source in low-doses (0/2,5/5/7,5/10/15/20 and 25 Gy); half population was kept in colonies (allowing cross fertilization) and the other half was mantained in sexual isolation (allowing self fertilization). Results showed that 15 Gy stimulates the fertility of both groups but the colonies were more sensitive and at this dose its fertility overpasses the control group dose. The possible hormonal role played in the observed phenomena is under investigation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance imaging is a rapidly developing modality in cardiology. It offers an excellent image definition and a large field of view, allowing a more accurate morphological assessment of cardiac malformations. Due to its unique versatility and its ability to provide myocardial tissue characterization, cardiac magnetic resonance (CMR) is now recognized as a central imaging modality for a wide range of congenital heart diseases, including assessment of post-surgical cardiac anatomy, quantification of valvular disease and detection of myocardial ischemia. CMR provides useful diagnostic information without any radiation exposure, and improves the global management of patients with congenital heart disease.