998 resultados para >1 mm


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stability of the conservative condylectomy technique and articular disc repositioning as the surgical treatment approach for management of mandibular condylar osteochondroma, with appropriate Orthognathic surgery. Fifteen patients (12 females and 3 males), average age of 32.3 years (range, 13 to 56 years), with unilateral active osteochondroma of the mandibular condyle were analyzed. All patients underwent conservative condylectomy, recontouring of the remaining condylar neck stump and articular disc repositioned and indicated orthognatic surgical procedures. Average post surgical follow-up was 19 months. Each patient's lateral cephalograms were traced at 3 intervals (presurgery, immediate post surgery and long-term follow-up). Immediate after surgery the oclusal plane angle decreased -2.8 ± 4.5o, the maxillomandibular complex rotated counter-clockwise with advancement at menton 5.3 ± 5.6 mm, pogonion 5.0 ± 5.1 mm, B point 3.4 ± 4.2 mm and A point 1.0 ± 1.5 mm. The long-term follow-up showed significant changes in overbite (-0.6 ± 0.5 mm) and SNGoMe (0,93° ± 1,53°). Horizontally and vertically small instabilities occurred in Me (-1.21 ± 1.94 mm) and PNS (-1.48 ± 1.67 mm) respectively. The treatment protocol studied produced counterclockwise rotation and maxillofacial mandibular advancement. The long-term follow-up showed solid dental and skeletal stability with horizontal instability of Me and PNS in the vertical direction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Central mechanisms of coupling between respiratory and sympathetic systems are essential for the entrainment between the enhanced respiratory drive and sympathoexcitation in response to hypoxia. However, the brainstem nuclei and neuronal network involved in these respiratory-sympathetic interactions remain unclear. Here, we evaluated whether the increase in expiratory activity and expiratory-modulated sympathoexcitation produced by the peripheral chemoreflex activation involves the retrotrapezoid nucleus/parafacial respiratory region (RTN/pFRG). Using decerebrated arterially perfused in situ rat preparations (60–80 g), we recorded the activities of thoracic sympathetic (tSN), phrenic (PN), and abdominal nerves (AbN) as well as the extracellular activity of RTN/pFRG expiratory neurons, and reflex responses to chemoreflex activation were evaluated before and after inactivation of the RTN/pFRG region with muscimol (1 mM). In the RTN/pFRG, we identified late-expiratory (late-E) neurons (n = 5) that were silent at resting but fired coincidently with the emergence of late-E bursts in AbN after peripheral chemoreceptor activation. Bilateral muscimol microinjections into the RTN/pFRG region (n = 6) significantly reduced basal PN frequency, mean AbN activity, and the amplitude of respiratory modulation of tSN (P < 0.05). With respect to peripheral chemoreflex responses, muscimol microinjections in the RTN/pFRG enhanced the PN inspiratory response, abolished the evoked late-E activity of AbN, but did not alter either the magnitude or pattern of the tSN reflex response. These findings indicate that the RTN/pFRG region is critically involved in the processing of the active expiratory response but not of the expiratory-modulated sympathetic response to peripheral chemoreflex activation of rat in situ preparations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of specimen size, in comparison with the ISO Standard, on the three point flexural strength of resin composite restorative materials Filtek Supreme and Filtek Z-250. Forty specimens were fabricated for each material with the following length, width and thickness measurements (n = 10): 1) 20 × 2 × 2 mm (ISO 4049); 2) 10 × 2 × 1 mm; 3) 10 × 1 × 1 mm; 4) 8 × 0.8 × 0.8 mm. The composites were inserted in a single increment into two-piece metal device and light-polymerized. The specimens were dry stored at 37 ± 1 °C and protected from light for 7 days. After this period, flexural strength was measured by three-point flexure test using MTS 810 equipment, with a load cell of 10 kN at a speed of 0.5 mm/min. For the evaluated sizes, the results showed significant variability (p = 0.00) with values when compared with the ISO Standard (116.700 MPa), being statistically higher for the test specimens measuring 10 × 1 × 1 mm (142.530 MPa), similar for those of 10  ×  2  ×  1  mm (115.815 MPa) and lower for those of 8 × 0.8 × 0.8 mm (86.650 MPa). There was statistical equality (p = 0.08) for the studied composites (Filtek Supreme, 125.270 MPa; Filtek Z-250, 108.130 MPa). Specimens measuring 10 × 2 × 1 mm provided flexural strength values equivalent to those obtained in the sizes recommended by the ISO 4049 standard, with lower consumption of material, energy and time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this in vitro study was to comparatively evaluate the mesio and distal furcation entrance measurements of first maxillary premolar. The measurements were compared with different curette blades. A caliper was used by an examinator to acquire the measurements of root trunk (TR); 1 mm (D1) and 2 mm (D2) both below the furcation entrance. For this study Gracey, Mini Gracey, Padua Lima (PL) and Goldman Fox 4 curettes (Millenium) were selected. Measurements of DT - total distance of the active blade length, DI - width of the active blade, DM - width of the medium part of the active blade were obtained for the curettes. The measurements were obtained in both the coronary face and in the lateral face. The data TR, D1 and D2 presented normal distribution and were statistically analyzed by paired t-test. Statistically significant differences were found in the mesial root trunk region (TR) of both premolars. The mean of the measurements was greater than the distal. Mean and standard deviation were obtained, and both Gracey and Mini Gracey showed mean measurements compatible with the closer furcation entrance (D1 - 1 mm). Goldman Fox 4 showed adaptation only in the mesial face, and Padua Lima showed no access to any of the faces. Thereby it is concluded that the access of the furcation is narrow (D1). The mesial face of the root trunk (TR) showed mean measurement greater than distal face. Gracey and Mini Gracey curettes demonstrated to be compatible for both faces, mesial and distal of the first maxillary premolars studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT. Introduction: an in vitro model was used to measure the hydraulic conductance in human dentin discs treated with oxalic acid for 15, 30 or 60 s maintaining the occlusive effect and measuring 7 and 14 days after application. Methods: 45 dentin discs measuring 1 mm thick were obtained from human third molars which were free of caries and in no occlusion; the samples were obtained from patients aged 16 to 30 years. Discs were sorted out into three study groups (n = 15) depending on the time of application of a commercial solution of oxalate-based dentin desensitizer (DD) (BisBlock®) which contains ˂ 5% oxalic acid of 1.5-1.8 pH: in group A the agent was applied for 15 s, in group B it was applied for 30 s, and in group C for 60 s. The hydraulic conductance of each disc was calculated after acid etching, which corresponds to the maximum permeability of discs (100%) after immediate application of oxalic acid, as well as seven and fourteen days of storage in saline solution. The statistical analysis was done with ANOVA test and post-hoc Games-Howell test. Results: 35,46 ± 23.41% in Group A, 36.34 ± 15.88% in Group B and 24.99 ± 14.99% in Group C, showing that the use of DD for 15, 30 or 60 s decreased permeability in a statistically significant manner (p <0.05). Conclusions: DD was effective in reducing hydraulic conductance regardless of application time, but this reduction was temporary only, since after seven days permeability returns to values close to those of baseline.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. OBJECTIVE: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. MATERIAL AND METHODS: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey's test. The level of significance was set at P < 0.05. RESULTS: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. CONCLUSION: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The irrigation of root canals aims to their cleaning and disinfection, improving endodontic treatment success. Objective: To investigate the influence of the diameter and type of irrigation needle and the root canal enlargement on the mechanical efficacy of endodontic irrigation. Material and methods: Twelve human single-rooted mandibular incisors were used. During some instrumentation stages (enlargement by #20, #30, and #40 K file), root canals were filled with radiographic contrast solution mixed to propyleneglycol and zinc oxide. Needles with different diameters and designs were employed: G1 – 23G and lateral opening; G2 – 22G and apical opening; G3 – 30G and lateral opening; G4 – 30G and apical opening. The needles were inserted up to resistance, with 1 mm step-back to avoid root canal obliteration. The irrigation was performed with 2 mL of distilled water. Before and after irrigation/aspiration, teeth were radiographed at bucco-lingual and mesiodistal direction, using a digital radiographic system. Then, root canal areas, before (filled by contrast solution) and after irrigation (remnant of contrast solution), were submitted to image subtraction with Adobe Photoshop CS4 software. Subsequently, the areas were measured by Image Tool 3.0 software, allowing the obtaining of the cleaning percentage for each modality. Data were analysed by using Anova and Tukey’s test. The level of significance was set at P < 0.05. Results: For all root canal enlargements, 30G needles (G3 e G4) presented a better cleaning efficacy. In all groups, higher cleaning efficacy percentage was observed at #30 and #40 K file enlargement. Conclusion: Regardless their design, thinner needles were more effective; a better cleaning efficacy occurred in more enlarged root canals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare the hydraulic conductance in human dentin disks, where 1, 2 or 3 layers of adhesive Single Bond 2(SB2) and Single Bond Universal(SBU) were applied. 84 1 mm. thick(+/- 0.1 mm.) dentin disks were fabricated. Samples were divided into 7 groups (n = 12) Control (without adhesive), A1: one layer of SB2, A2: two layers SB2, A3: three layers SB2, B1: one layer SBU, B2: two layers of SBU, B3: three layers of SBU. The results as averages for the hydraulic conductance of each separate group were: Control (0.0363), A1 (0.0206), A2 (0.0070), A3 (0.0061), B1 (0.0161), B2 (0.0062), B3(0.0056) expressed µl/min.cm2. There is statistically significant difference CH, between the control group and those samples that one coat was applied (p = 0.000) and also between the application of one and two layers (p = 0.000). No difference between the two adhesives (p = 0.434). Summary Key words: Dentin, conductance, difussion adhesive layers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the action of methyl salicylate in dissolving Resilon and gutta-percha. Material and method: Ten discs of Resilon, Alpha gutta-percha and ProTaper gutta-percha were prepared (10 mm diameter × 1 mm thick) and kept at 37 °C for 48 hours. Each sample was weighed in a balance of accuracy determining the initial mass. The specimens were immersed in methyl salicylate or xylene (control) for 5  minutes, rinsed in water for 30 minutes, dried and subsequently weighed in 24 hours intervals until the stabilization of weight (final mass). The solvent capacity was expressed by the difference between the final and initial mass. The data were analyzed by using ANOVA and Tukey test with significance level of 5%. Result: The results showed that the methyl salicylate was more effective on Resilon than on gutta-percha (p < 0.05). Methyl salicylate and xylene had similar solvent action on Resilon (p > 0.05). The xylene showed better performance on gutta-percha than methyl salicylate (p < 0.05). Conclusion: It was concluded that methyl salicylate did not show solvent action on gutta-percha, however it showed effectiveness in dissolution of Resilon. Thus methyl salicylate can be a possible alternative to the use of xylene during endodontic retreatment of teeth obturated with Resilon.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to characterize and to evaluate the bioactivity potential of experimental root canal sealers (ES) based on Portland cement, epoxy resin with nano- and micro-particles of niobium or zirconium oxide used as radiopacifiers in comparison to AH Plus and MTA Fillapex. Methods Specimens of the sealers (10 mm in diameter × 1 mm thick) were prepared and the radiopacity was evaluated according to ISO 6876 (2012) specifications. Characterization of the sealers was performed under the scanning electron microscope (SEM) immediately after setting and after immersion for 28 days in Hank's balanced salt solution (HBSS). In addition X-ray energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy were also performed. The pH and calcium ion release were measured after 1, 7, 14, 21 and 28 days after completion of seating using a digital pH meter and an atomic absorption spectrophotometer, respectively. Results The experimental sealers exhibited an average radiopacity of 2.5 mm thickness of aluminum, which was similar to MTA Fillapex (P > 0.05) and inferior to AH Plus (P < 0.05). AH Plus did not show bioactivity. Although the experimental sealers did not exhibit the formation of hydration product, they encouraged the deposition of crystalline spherical structures of calcium deficient phosphate. The highest pH and calcium release values were observed with the experimental sealers (P < 0.01). ES-Nb-micro was the only sealer to present hexagonal shaped crystal deposition. Significance Novel root canal sealers based on a mixture of Portland cement, epoxy resin and radiopacifier exhibited a degree of bioactivity although no evidence of cement hydration was demonstrated on material characterization. The radiopacifier particle size had limited effect on the sealer microstructure and chemical properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Population parameters of the shrimp Xiphopenaeus kroyeri (Heller, 1862) (sex ratio, length-frequency distributions (carapace length, CL), growth, lifespan, size of sexual maturity, spawning and recruitment) were analyzed in a long-term study from January 1998 through June 2003. The data on these parameters were collected and analyzed to test the hypothesis that the main period of juvenile recruitment in the bay coincides with the period of fishery closures currently designated by the Brazilian Institute of Environment and Renewable Natural Resources. Monthly collections were conducted along the southeastern Brazilian coast, using a shrimp fishing boat with “double-rig” nets sampling at stations up to 40 m depth. Sex ratios were female-biased only in zones with high reproductive activity such as in stations deeper than 15 m (χ2 test, p<0.05). The mean size of males and females was 15.3 ± 3.1 mm CL and 16.2 ± 4.7 mm CL, respectively, with size at sexual maturity estimates (CL50) of 14.8 mm for males and 15.5 mm for females. Mean growth curves provided estimates of CL∞ = 29.31 mm, k = 0.009/day, t0=−0.25 and CL∞ = 35.33 mm, k = 0.006/day, t0=−0.23 for males and females, respectively, and average lifespans of 1.35 for males and 2.12 years for females. Recruitment and abundances of reproductive females were highly correlated with the environmental factors such as higher water temperature and finer-grained bottom sediment (canonical correlation, r=0.63, p<0.001). The reproductive peaks in February-April 1998, March-May 1999 and February-May 2002 were followed by recruitment peaks in May-July 1998, July-September 1999 and April-June 2002, respectively. Thus, the proposed period of fisheries closure (March to May) does not coincide with the main recruitment periods observed for X. kroyeri.