980 resultados para visual detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is well known that color coding facilitates search and iden- tification in real-life tasks. The aim of this work was to compare reac- tion times for normal color and dichromatic observers in a visual search experiment. A unique distracter color was used to avoid abnormal color vision vulnerability to background complexity. Reaction times for nor- mal color observers and dichromats were estimated for 2◦ central vision at 48 directions around a white point in CIE L∗a∗b∗ color space for systematic examination on the mechanisms of dichromatic color percep- tion. The results show that mean search times for dichromats were twice larger compared to the normal color observers and for all directions. The difference between the copunctual confusion lines and the confusion direction measure experimentally was 5.5◦ for protanopes and 7.5◦ for deuteranopes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aims to advance blinking detection in the context of work activity. Rather than patients having to attend a clinic, blinking videos can be acquired in a work environment, and further automatically analyzed. Therefore, this paper presents a methodology to perform the automatic detection of eye blink using consumer videos acquired with low-cost web cameras. This methodology includes the detection of the face and eyes of the recorded person, and then it analyzes the low-level features of the eye region to create a quantitative vector. Finally, this vector is classified into one of the two categories considered —open and closed eyes— by using machine learning algorithms. The effectiveness of the proposed methodology was demonstrated since it provides unbiased results with classification errors under 5%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar o desempenho dos tipos de TDAH em tarefas de seletividade, sustentação e atenção alternada, considerando tempo médio de reação, número de erros por ação e número de erros por omissão em teste computadorizado de atenção visual (TAVIS-III). MÉTODOS: Cento e duas crianças e adolescentes de duas escolas particulares e uma escola pública da cidade do Rio de Janeiro, com idades entre 6 e 17 anos com diagnóstico de TDAH, segundo DSM-IV, foram submetidas ao TAVIS-III. A separação por grupos respeitou os tipos determinados por entrevista semi-estruturada (P-CHIPS), e os resultados foram comparados levando-se em consideração o fator grupo. RESULTADOS: O tipo combinado (C) revelou-se o mais comum (n = 65; 63,7%), seguido pelo predominantemente desatento (D) (n = 32; 31,4%). O tipo predominantemente hiperativo-impulsivo (HI) foi excluído das análises estatísticas em virtude da baixa freqüência. O desempenho do grupo C revelou-se inferior apenas em tarefa de atenção sustentada, no que tange ao número de erros por ação e tempo médio de reação (p < 0,05), ambos maiores quando comparados ao grupo D. CONCLUSÃO: Apenas em tarefa de atenção visual por tempo mais prolongado, o tipo combinado revelou diferenças significativas em relação ao grupo desatento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia e Gestão da Qualidade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Compare pattern of exploratory eye movements during visual scanning of the Rorschach and TAT test cards in people with schizophrenia and controls. METHOD: 10 participants with schizophrenia and 10 controls matched by age, schooling and intellectual level participated in the study. Severity of symptoms was evaluated with the Positive and Negative Syndrome Scale. Test cards were divided into three groups: TAT cards with scenes content, TAT cards with interaction content (TAT-faces), and Rorschach cards with abstract images. Eye movements were analyzed for: total number, duration and location of fixation; and length of saccadic movements. RESULTS: Different pattern of eye movement was found, with schizophrenia participants showing lower number of fixations but longer fixation duration in Rorschach cards and TAT-faces. The biggest difference was observed in Rorschach, followed by TAT-faces and TAT-scene cards. CONCLUSIONS: Results suggest alteration in visual exploration mechanisms possibly related to integration of abstract visual information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado Internacional em Sustentabilidade do Ambiente Construído

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doctoral Dissertation for PhD degree in Chemical and Biological Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare single-photon-emission computed tomography (SPECT) imaging scans using 201Tl and 99mTc-MIBI in detection of viable myocardium, in regions compromised by infarction. METHODS: Thirty-two (59.3±9.8 years old and 87% male) myocardial infarction patients were studied. All had Q waves on the ECG and left ventricle ejection fraction of <50%. They underwent coronary and left ventricle angiographies and SPECT before (including 201Tl reinjection) and after coronary artery bypass surgery (CABG). Improvement in perfusion observed after surgery was considered the gold standard for myocardial viability. RESULTS: Among 102 studied regions of the heart, there were 40 (39.2%) areas of transient perfusion defects in the conventional protocol with 201Tl and 52 (51.0%) after reinjection. Therefore, 12/62 (19.4%) more viable regions were identified by reinjection. Using 99mTc-MIBI, only 14 (13.7%) regions with transient defects were identified, all of which were seen also in 201Tl protocols. After surgery, 49 of a total of 93 regions analyzed (52.7%) were viable. Sensitivity, specificity, accuracy, positive and negative prediction values were, respectively, 201Tl SPECT scans - 65.3%, 90.9%, 77.4%, 88.9% and 70.2%, reinjection protocol with 201Tl scans - 81.6%, 81.8%, 81.7%, 83.3% and 80.0%; 99mTc-MIBI SPECT scans - 20.4%, 90.9%, 53.8%, 71.4% and 50.6%. Logistic regression demonstrated that the reinjection protocol with 201Tl was the best predictor of viability (P<0.001). CONCLUSION: Our data suggest the election of 201Tl for viability studies, especially when using the reinjection protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors consider the possibility of using color Doppler of the ductus venosus and the measurement of nuchal translucency as a screening test for alterations in fetal cardiac functions in the first trimester of gestation. Review of the literature suggests that the combination of the ultrasonographic measurement of nuchal translucency and Doppler at 10 and 14 weeks of gestation can be effective in detecting certain cardiac abnormalities. This conclusion, however, is preliminary and needs to be further investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure for the simultaneous detection of cyclopiazonic acid (CPA) and aflatoxin B1 from fungal extracts is presented, using a methanol and water mobile phase and fluorescence detection. This methodology has been tested with standard solutions of both mycotoxins CPA and Aflatoxin B1 and with methanolic extracts of Aspergillus section Flavi strains, previously characterized for their mycotoxin production profile. Previously available methodology required the use of two different chromatographic runs for these mycotoxins, with distinct columns and detectors (fluorescence detection with a post-column photochemical derivatization (PHRED) for aflatoxin B1 and UV detection for CPA). The proposed method detects both mycotoxins in a single run. Data from these assays will be presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ochratoxin A (OTA) is a very well known mycotoxin found in several food commodities for which maximum limits are being discussed in EC in other to produce appropriate regulations. OTA is one of several ochratoxins produced by Aspergillus and Penicillium species. All the compounds in this group have a molecular structure very similar to OTA and some were already isolated from natural substrates. Several of these compounds such as ochratoxin , methyl and ethyl ester of ochratoxin A, 4-R and S-hydroxyochratoxin A, 10-hydroxyochratoxin A and ochratoxin A open lactone are commercially unavailable. However, they can be easily synthesized through OTA modification. With the main objective of its application on further research works, OTA production, isolation and purification has been optimised from an A. alliaceus strain grown on wheat medium. Synthesis and purification of some OTA derivatives has been achieved and an HPLC method for their detection was optimised. Data about their production by several species of Aspergillus will be presented. The toxicological properties of ochratoxins are still not very clear and a future EC safety limit for OTA will depend on e.g., a better clarification of its carcinogenity. Could OTA derivatives play a role here?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence in situ hybridization (FISH) is a molecular technique widely used for the detection and characterization of microbial populations. FISH is affected by a wide variety of abiotic and biotic variables and the way they interact with each other. This is translated into a wide variability of FISH procedures found in the literature. The aim of this work is to systematically study the effects of pH, dextran sulfate and probe concentration in the FISH protocol, using a general peptide nucleic acid (PNA) probe for the Eubacteria domain. For this, response surface methodology was used to optimize these 3 PNA-FISH parameters for Gram-negative (Escherichia coli and Pseudomonas fluorescens) and Gram-positive species (Listeria innocua, Staphylococcus epidermidis and Bacillus cereus). The obtained results show that a probe concentration higher than 300 nM is favorable for both groups. Interestingly, a clear distinction between the two groups regarding the optimal pH and dextran sulfate concentration was found: a high pH (approx. 10), combined with lower dextran sulfate concentration (approx. 2% [w/v]) for Gram-negative species and near-neutral pH (approx. 8), together with higher dextran sulfate concentrations (approx. 10% [w/v]) for Gram-positive species. This behavior seems to result from an interplay between pH and dextran sulfate and their ability to influence probe concentration and diffusion towards the rRNA target. This study shows that, for an optimum hybridization protocol, dextran sulfate and pH should be adjusted according to the target bacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Ciências da Comunicação (área de especialização em Audiovisuais e Multimédia)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.