998 resultados para substrate screening


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article gives an extensive overview of the wide range of analytical procedures developed for the detection of amphenicol antibiotic residues (chloramphenicol, thiamphenicol, and florfenicol) in many different types of foodstuffs (milk, meat, eggs, honey, seafood). Screening methods such as microbial inhibition methods, antibody-based immunoassays using conventional and biosensor-based detection systems, and some methods based on alternative recognition systems are described. The relative advantages and disadvantages of these methods are discussed and compared. The current status and future trends and developments in the need for accurate and rapid detection of this group of antimicrobials are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzyme-linked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitive and specific enzyme-linked immunosorbent assays (ELISAs) were developed for the detection of two illegal synthetic dyes: Methyl Yellow (MY) and Rhodamine B (RB) in food. Polyclonal antibodies were raised against synthesised immunogens and employed in unique direct disequilibrium ELISAs. The time of the assays was only twenty minutes (five minutes for each incubation step with sample and enzyme conjugate and ten minutes with enzyme substrate). The IC50 for MY was in the range 1.4-4.2 ng mL(-1) and for RB 0.1-0.5 ng mL(-1). A simple sample preparation method was developed for the analysis of a range of sauces. In the case of spices a dispersive solid phase extraction was applied to purify the extracts. The testing of twenty samples took approximately one and a half hours (including sample preparation and analysis). Both assays were validated according to the Commission Decision 2002/657/EC criteria for use in sauces and spices. The detection capability for MY in sauces and spices was determined to be less than 15 ng g(-1) and 50 ng g(-1), respectively and for RB, 10 ng g(-1) for both types of food samples. The precision of the developed assays was determined in a repeatability study. The intra-and inter-assay coefficients of variation were less than 25% for both tests and matrix types. The simplicity and performance of both assays indicate that they will be very reliable screening methods for the detection of the illegal dyes MY and RB in a range of food products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An LC/MS/MS method was developed and validated for the simultaneous identification, confirmation, and quantification of 12 glucocorticoids in bovine milk. The method was validated in accordance with the criteria defined in Commission Decision 2002/657/EC. The developed method can detect and confirm the presence of dexamethasone, betamethasone, prednisolone, flumethasone, 6 alpha-methylprednisolone, fluorometholone, triamcinolone acetonide, prednisone, cortisone, hydrocortisone, clobetasol propionate, and clobetasol butyrate in bovine milk. Milk samples are extracted with acetonitrile; sodium chloride is subsequently added to aid partition of the milk and acetonitrile mixture. The acetonitrile extract is then subjected to liquid-liquid purification by the addition of hexane. The purified extract is evaporated to dryness and reconstituted in a water acetonitrile mixture, and determination is carried out by LC/MS/MS. The method permits analysis of up to 30 samples in 1 day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na+ ions have a detrimental effect on the photocatalytic activity of thin sot gel films deposited on soda lime glass due to their diffusion into the film during the calcination process. Given that the content of sodium in glass substrate might be the crucial parameter in determining the activity of a photocatalyst, the aim of the present work was the comparison of the photoinduced properties of a thin TiO2 film prepared on three different glass substrates namely on quartz (Q) glass, borosilicate (BS) glass and soda lime (SL) glass which have different sodium content. The prepared layers were characterised by X-ray diffraction and UV-vis spectroscopy. The diffusion of Na+ from the substrate into the layers was determined by Glow Discharge Atomic Emission Spectroscopy. The photocatalytic activities of the films were assessed using two model pollutant test systems (resazurin/resorufin ink and stearic acid film), which appeared to correlate reasonably well. It was observed that TiO2 layer on SL glass has a brookite crystalline structure while the TiO2 layer on BS and Q glass has an anatase crystalline structure. On the other hand, the photodegradation of the model dye on TiO2 films deposited on Q and BS glass is about an order higher than on SL glass. The low sodium content of BS glass makes it the most suitable substrate for the deposition of photoactive sol gel TiO2 films. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An intelligent ink, previously shown to be capable of rapidly assessing photocatalytic activity, was simply applied via a felt-pen onto a commercially available piece of Activ (TM) self-cleaning glass. The ink, comprising of redox dye resazurin and the sacrificial electron donor glycerol within an aqueous hydroxy ethyl cellulose (HEC) polymer media, was photocatalytically degraded in a two-step process. The key initial stage was the photo-reductive conversion of resazurin to resorufin, whereby a colour change from blue to pink occurred. The latter stage was the subsequent photo-reduction of the resorufin, where a slower change from pink to colourless was seen. Red and green components of red-green-blue colour extracted from flat-bed scanner digital images of resazurin ink coated photocatalytic films at intervals during the photocatalysis reaction were inversely proportional to the changes seen via UV-visible absorption spectroscopy and indicative of reaction kinetics. A 3 x 3 grid of intelligent ink was drawn onto a piece of Activ (TM) and a glass blank. The photocatalysis reaction was monitored solely by flat-bed digital scanning. Red-green-blue values of respective positions on the grid were extracted using a custom-built program entitled RGB Extractor (c). The program was capable of extracting a number of 5 x 5 pixel averages of red-green-blue components simultaneously. Allocation of merely three coordinates allowed for the automatic generation of a grid, with scroll-bars controlling the number of positions to be extracted on the grid formed. No significant change in red and green components for any position on the glass blank was observed; however, the Activ (TM) film displayed a homogenous photo-reduction of the dye, reaching maxima in red and minima in green components in 23 +/- 3 and 14 +/- 2 min, respectively. A compositionally graded N-doped titania film synthesised in house via a combinatorial APCVD reaction was also photocatalytically tested by this method where 247 positions on a 13 x 19 grid were simultaneously analysed. The dramatic variation in photocatalysis observed was rapidly quantified for all positions (2-3 hours) allowing for correlations to be made between thicknesses and N : Ti% compositions attained from Swanepoel and WDX analysis, respectively. N incorporation within this system was found to be detrimental to film activity for the photocatalysis reaction of intelligent ink under 365 nm light.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automated immunoassay for the detection of nicarbazin residues in poultry eggs and liver was developed. The assay was based on a novel all-in-one dry chemistry concept and time-resolved fluorometry. The analyte specific antibody was immobilized into a single microtiter well and covered with an insulation layer, on top of which the label was dried in a small volume. The extracted sample was added automatically to the dry microtiter well, and the result was available within 18 min. Due to the rapidity and simplicity, the quantitative immunoassay could also be used as a high throughput screening method. The analytical limit of detection for the assay was calculated as 0.1 ng mL(-1) (n = 12) and the functional limit of detection as 3.2 ng g(-1) for egg (n = 6) and 11.3 ng g(-1) for liver (n = 6) samples. The sample recovery varied from 97.3 to 115.6%. Typically, the intra-assay variations were less than 10%, and interassay variations ranged between 8.1 and 13.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Techniques for screening porcine samples for antimicrobial residues in the EU usually involve analysis of samples taken post slaughter, and are either time consuming or expensive. Some of the positive test results at this screening stage could be avoided by allowing the animal sufficient withdrawal time following drug treatment. A method is described that can detect the presence of five major antibiotics in porcine urine at concentrations below 1 mu g ml(-1) for each of the compounds. The test uses Bacillus subtilis, which is already widely employed in antimicrobial inhibition assays, and when combined with a colorimetric substrate, p-nitrophenyl-beta-D-glucopyranoside, can detect inhibitory substances within an assay time of four and a half hours. The method, which uses microtitre plate technology, could be developed into a convenient test kit for use at farm level to determine whether animals were still excreting antimicrobials in their urine prior to their submission for slaughter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was conducted to determine the feasibility of performing

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid imununoassay using an optical biosensor (BIAcore(TM)) for determining the presence of sulphadiazine (SDZ) residues in pig bile was developed. SDZ,cas immobilised onto the surface of a dextran-coated silicon chip and a solution containing SDZ antibody, sample and buffer was injected over the chip surface. The level of antibody binding to the chip was determined after 20 s and the surface of the chip was then regenerated over a 1-min period prior to another sample injection taking place. Standard curves were constructed to allow quantification of SDZ presence in sample. Concentrations ranging from 0 to 10.64 mu g ml(-1) SDZ were detected in bile samples taken from experimentally fed pigs and randomly selected pigs taken from a local slaughterhouse. These results were compared to the concentrations of SDZ detected by high-performance liquid chromatography: in associated tissues. When concentrations in bile exceeded 0.6 mu g ml(-1) SDZ, the corresponding edible tissue was above the maximum residue level (MRL), i.e. 0.1 mu g g(-1) in 13 out of 14 cases. Wizen the bile concentration was less than 0.6 mu ml(-1) the associated tissue concentrations never exceeded rite MRL. This experiment has indicated that biosensor analysis of bile is a highly effective method for detecting violative SDZ residues in meat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ractopamine (RCT) is a phenethanolamine member of the family of beta-adrenergic agonists (beta-agonists), This class of compounds have become notable for their properties of enhancing the growth rates of farm animal species but are not licensed for use in Europe. An ELISA procedure employing a polyclonal antibody raised in a goat was developed to detect RCT residues in bovine urine samples, The assay had a high sensitivity (calibration curve mid-point of 22 pg per well), allowing the analysis of urine samples without the need for sample clean-up. In addition, an LC-MS-MS confirmatory procedure was developed which was able to act as a confirmatory procedure for the ELISA results. Four calves were orally treated with RCT (0.1 mg kg(-1) body mass for 17 d) and urine samples collected were assayed by both analytical procedures. It was observed that RCT residues were excreted mainly in the form of glucuronides and deconjugation could be achieved using two different sources of the enzyme beta-glucuronidase (Helix pomatia and Escherichia coli), High concentrations of RCT residues were found throughout the medication period (44-473 ng ml(-1); LC-MS-MS data) and remained present for several days following removal of the drug from the diet, RCT residues were no longer detectable 2 weeks after withdrawal, Good agreement (r(2) = 0.73) was achieved between the ELISA and LC-MS-MS results, especially when sample deconjugation was applied to the urine samples for both sets of analyses, The results show that an effective screening and confirmatory system was devised to detect RCT residues in urine samples taken during treatment and close to withdrawal, However, alternative matrices may have to be selected to allow the illegal use of the substance to be detected following prolonged withdrawal times.