990 resultados para SEMICONDUCTOR LASERS
Resumo:
BACKGROUND: Low-dose, Visudyne®-mediated photodynamic therapy (photo-induction) was shown to selectively enhance tumor vessel transport causing increased uptake of systemically administered chemotherapy in various tumor types grown on rodent lungs. The present experiments explore the efficacy of photo-induced vessel modulation combined to intravenous (IV) liposomal cisplatin (Lipoplatin®) on rodent lung tumors and the feasibility/toxicity of this approach in porcine chest cavities. MATERIAL AND METHODS: Three groups of Fischer rats underwent orthotopic sarcoma (n = 14), mesothelioma (n = 14), or adenocarcinoma (n = 12) implantation on the left lung. Half of the animals of each group had photo-induction (0.0625 mg/kg Visudyne®, 10 J/cm(2) ) followed by IV administration of Lipoplatin® (5 mg/kg) and the other half received Lipoplatin® without photo-induction. Then, two groups of minipigs underwent intrapleural thoracoscopic (VATS) photo-induction (0.0625 mg/kg Visudyne®; 30 J/cm(2) hilum; 10 J/cm(2) apex/diaphragm) with in situ light dosimetry in combination with IV Lipoplatin® administration (5 mg/kg). Protocol I (n = 6) received Lipoplatin® immediately after light delivery and Protocol II (n = 9) 90 minutes before light delivery. Three additional animals received Lipoplatin® and VATS pleural biopsies but no photo-induction (controls). Lipoplatin® concentrations were analyzed in blood and tissues before and at regular intervals after photo-induction using inductively coupled plasma mass spectrometry. RESULTS: Photo-induction selectively increased Lipoplatin® uptake in all orthotopic tumors. It significantly increased the ratio of tumor to lung Lipoplatin® concentration in sarcoma (P = 0.0008) and adenocarcinoma (P = 0.01) but not in mesothelioma, compared to IV drug application alone. In minipigs, intrapleural photo-induction combined to systemic Lipoplatin® was well tolerated with no toxicity at 7 days for both treatment protocols. The pleural Lipoplatin® concentrations were not significantly different at 10 and 30 J/cm(2) locations but they were significantly higher in protocol I compared to II (2.37 ± 0.7 vs. 1.37 ± 0.7 ng/mg, P < 0.001). CONCLUSION: Visudyne®-mediated photo-induction selectively enhances the uptake of IV administered Lipoplatin® in rodent lung tumors. Intrapleural VATS photo-induction with identical treatment conditions combined to IV Lipoplatin chemotherapy is feasible and well tolerated in a porcine model. Lasers Surg. Med. 47:807-816, 2015. © 2015 Wiley Periodicals, Inc.
Resumo:
Objetivos: Este trabajo pretende, en base a nuestra experiencia, valorar y discutir las indicaciones, ventajas e inconvenientes de la exéresis de los épulis de la cavidad bucal con el láser de dióxido de carbono (CO2) respecto al láser de Erbio:YAG (Er:YAG), el láser de diodo y el bisturí frío. Material y método: Se ha realizado un estudio retrospectivo de un grupo de 120 pacientes en los que se extirparon 128 épulis con el láser de CO2, láser de Er:YAG, láser de diodo y bisturí frío. Se realizaron controles postoperatorios a los 7, 15 y 30 días para comprobar la cicatrización y la evolución de la herida y a los 3, 6 y 12 meses verificando si se había producido o no la recidiva de la lesión. Resultados: Según las características clínicas y etiopatogénicas de las lesiones extirpadas, se han formado dos grupos: las lesiones hiperplásicas gingivales (77 casos) y los épulis fisurados (51 casos). La localización más frecuente de las hiperplasias gingivales fue la mandíbula (51.9%). Se encontró que la hiperplasia fibrosa fue el diagnóstico histopatológico más frecuente con 49 casos (63.6%). El porcentaje de recidiva tras su extirpación fue del 9,1%, de los cuales 5 casos eran hiperplasias fibrosas. Sólo hubo un caso de lesión maligna que fue diagnosticada de carcinoma de células escamosas infiltrante. Por otro lado, de los 51 épulis fisurados tratados, el 58.8% se encontraban en el maxilar superior. Éstos fueron diagnosticados histológicamente como hiperplasias fibrosas, recidivando en el 19.6% de los casos. Conclusiones: Aunque las diferentes técnicas quirúrgicas utilizadas en la extirpación del épulis de la cavidad bucal son correctas, en nuestra opinión, el láser de CO2 es el tratamiento de elección, ya que ofrece ventajas tanto intra como postoperatorias. Por otro lado, es indispensable analizar histopatológicamente toda lesión de la cavidad bucal para establecer un diagnóstico de certeza
Resumo:
Objetivos: Este trabajo pretende demostrar que se pueden realizar la mayoría de las intervenciones quirúrgicas de la cavidad bucal en la población pediátrica en un medio ambulatorio, así como valorar y mostrar la actividad realizada en el Máster de Cirugía e Implantología Bucal de la Facultad de Odontología de la Universidad de Barcelona durante el año 2000. Diseño del estudio: Para la realización de este trabajo se ha contabilizado la actividad quirúrgica de las unidades de cirugía bucal y cirugía con láser en la población pediátrica en el Máster de Cirugía e Implantología Bucal de la Universidad de Barcelona. Resultados: De las 3187 intervenciones quirúrgicas realizadas en nuestro servicio, 489 fueron en pacientes menores de 18 años. La exodoncia quirúrgica de terceros molares inferiores fue la más frecuente (55'6%), seguida de otras extracciones dentarias (33'6%), quirúrgicas o no, y del resto de intervenciones (10'6%) que incluyeron: fenestraciones de caninos u otros dientes incluidos, exéresis de frenillos, de mucoceles y reubicaciones dentarias. Se presentaron complicaciones tras la extracción quirúrgica de los terceros molares en un 15'93% de los casos, siendo las más frecuentes el dolor (4'35%) y la tumefacción (4'35%), signos propios de la inflamación postoperatoria. Conclusiones: Nuestra experiencia muestra que la cirugía bucal ambulatoria puede practicarse de forma segura en la población pediátrica siempre y cuando se disponga de los medios y del personal sanitario adecuados
Resumo:
OBJETIVO: Avaliar a reprodutibilidade do posicionamento de pacientes com diagnóstico de câncer de próstata submetidos a radioterapia conformada. MATERIAIS E MÉTODOS: Foram avaliados 960 (posições anterior e lateral) filmes radiológicos, de um total de 120 pacientes que receberam radioterapia conformada na próstata com técnica isocêntrica. As imagens foram obtidas em acelerador linear de partículas 6 MV. Aplicou-se protocolo específico para planejamento e tratamento da próstata, com o paciente em posição supina, mãos colocadas sobre o tórax, pés apoiados em suporte apropriado. Diariamente, os pacientes foram posicionados conforme demarcações na pele, coincidentes com os lasers da sala. Os filmes radiológicos foram comparados com as radiografias reconstruídas digitalmente (digitally reconstructed radiography - DRR) em sistema de planejamento computadorizado Eclipse, a partir das tomografias. As radiografias de posicionamento foram realizadas no primeiro dia e após, semanalmente, até o término do tratamento. RESULTADOS: As médias dos deslocamentos observados foram de 1,99 ± 1,25 mm no sentido crânio-caudal, 1,37 ± 0,84 mm no látero-lateral e 1,94 ± 1,10 mm no ântero-posterior. CONCLUSÃO: O uso de protocolos específicos para posicionamento dos pacientes é possível na prática clínica, possibilita reprodutibilidade adequada e rápida correção dos possíveis erros.
Resumo:
The possibility of printing two-dimensional micropatterns of biomolecule solutions is of great interest in many fields of research in biomedicine, from cell-growth and development studies to the investigation of the mechanisms of communication between cells. Although laser-induced forward transfer (LIFT) has been extensively used to print micrometric droplets of biological solutions, the fabrication of complex patterns depends on the feasibility of the technique to print micron-sized lines of aqueous solutions. In this study we investigate such a possibility through the analysis of the influence of droplet spacing of a water and glycerol solution on the morphology of the features printed by LIFT. We prove that it is indeed possible to print long and uniform continuous lines by controlling the overlap between adjacent droplets. We show how, depending on droplet spacing, several printed morphologies are generated, and we offer, in addition, a simple explanation of the observed behavior based on the jetting dynamics characteristic of the LIFT of liquids.
Resumo:
The plasma etching of semiconductor surfaces with fluorine-containing compounds has technological interest. Presently, considerable effort is being devoted to understand the chemistry involved. In this work, a numerical modeling analysis of the gas-phase decomposition of CF4/O2 mixtures, in the presence of silicon, was performed. The relative importance of individual processes was determined as well as the effect of the parameters' uncertainties. The results were compared with experimental data. The main etching agent in the system is the fluorine atom. The concentration of the main species, SiF4, CO, CO2 and COF2 depend on the composition of the mixture.
Resumo:
Multicomponent ( Al2O3, CaO, SiO2, MgO) calcium aluminate-based glasses containing Nd3+ were prepared in order to evaluate their possibilities as laser host materials. The refractive index, UV-visible-near IR absorption spectrum, IR and visible luminescence spectra, and fluorescence decay time were measured. Judd-Ofelt model was used to obtain experimental intensity parameters ( omega2, omega4 and omega6), emission cross-section, radiative lifetimes, emission branching ratios and quantum efficiency.
Resumo:
Nanoparticles offer adjustable and expandable reactive surface area compared to the more traditional solid phase forms utilized in bioaffinity assays due to the high surface to-volume ratio. The versatility of nanoparticles is further improved by the ability to incorporate various molecular complexes such as luminophores into the core. Nanoparticle labels composed of polystyrene, silica, inorganic crystals doped with high number of luminophores, preferably lanthanide(III) complexes, are employed in bioaffinity assays. Other label species such as semiconductor crystals (quantum dots) or colloidal gold clusters are also utilized. The surface derivatization of such particles with biomolecules is crucial for the applicability to bioaffinity assays. The effectiveness of a coating is reliant on the biomolecule and particle surface characteristics and the selected coupling technique. The most critical aspects of the particle labels in bioaffinity assays are their size-dependent features. For polystyrene, silica and inorganic phosphor particles, these include the kinetics, specific activity and colloidal stability. For quantum dots and gold colloids, the spectral properties are also dependent on particle size. This study reports the utilization of europium(III)-chelate-embedded nanoparticle labels in the development of bioaffinity assays. The experimental covers both the heterogeneous and homogeneous assay formats elucidating the wide applicability of the nanoparticles. It was revealed that the employment of europium(III) nanoparticles in heterogeneous assays for viral antigens, adenovirus hexon and hepatitis B surface antigen (HBsAg), resulted in sensitivity improvement of 10-1000 fold compared to the reference methods. This improvement was attributed to the extreme specific activity and enhanced monovalent affinity of the nanoparticles conjugates. The applicability of europium(III)-chelate-doped nanoparticles to homogeneous assay formats were proved in two completely different experimental settings; assays based on immunological recognition or proteolytic activity. It was shown that in addition to small molecule acceptors, particulate acceptors may also be employed due to the high specific activity of the particles promoting proximity-induced reabsorptive energy transfer in addition to non-radiative energy transfer. The principle of proteolytic activity assay relied on a novel dual-step FRET concept, wherein the streptavidin-derivatized europium(III)-chelate-doped nanoparticles were used as donors for peptide substrates modified with biotin and terminal europium emission compliant primary acceptor and a secondary quencher acceptor. The recorded sensitized emission was proportional to the enzyme activity, and the assay response to various inhibitor doses was in agreement with those found in literature showing the feasibility of the technique. Experiments regarding the impact of donor particle size on the extent of direct donor fluorescence and reabsorptive excitation interference in a FRET-based application was conducted with differently sized europium(III)-chelate-doped nanoparticles. It was shown that the size effect was minimal
Resumo:
Tässä työssä tarkastellaan taajuusmuuttajan vanhenemista syklisissä käytöissä puolijohdetehokomponenttien osalta. Laitteiden vikaantumisprosessien analysoimiseksi työssä suunnitellaan syklinen kestotestausjärjestelmä, joka mahdollistaa useamman taajuusmuuttajan yhtäaikaisen vanhentamisen. Jaksottaisesti toistuvat kuormitussyklit rasittavat termomekaanisesti taajuusmuuttajan tehomoduulin sisäisiä rakenteita suurten lämpötilavaihtelujen johdosta. Teoriaosuuden pääpaino kohdistuu puolijohdetehokomponenttien rakenteeseen, vikaantumisprosesseihin ja eliniän kartoittamiseen. Työssä käydään läpi yleisimpien pienijännitteisten moottorinohjausinverttereiden tehomoduulien mekaaniset rakenteet, tyypillisemmät syklisestä kuormituksesta johtuvat vikaantumisprosessit sekä puolijohdetehokomponenttivalmistajien käyttämät syklisen eliniän testausmenetelmät. Loppuosassa työtä suunnitellaan taajuusmuuttajan syklinen kestotestausjärjestelmä laitteiden keinotekoista vanhentamista varten. Testausjärjestelmällä voidaan kuormittaa useampaa taajuusmuuttajaa vuorottain mielivaltaisella kuormitusvirtaprofiililla. Laitteita vanhennettiin kaksi testierää kuormittamalla niitä jaksottaisesti hissikäytön tyypillisellä kuormitusprofiililla. Puolijohdetehokomponentin vanhenemisen edistystä seurattiin termisen impedanssiketjun mittausmenetelmällä, joka perustuu IGBT:n kollektoriemitterijännitteen lämpötilariippuvuuteen. Testilaitteiden puolijohdetehokomponentit hajosivat syklisen eliniän päättymiseen teoriassa esitettyjen vikaantumisprosessien seurauksesta. Tehomoduulien vika-analyysi osoittaa syklisen kestotestausjärjestelmän soveltuvaksi menetelmäksi tutkia erilaisten kuormitusprofiilien vaikutusta taajuusmuuttajan vanhenemiseen.
Resumo:
Advancements in power electronic semiconductor switching devices have lead to significantly faster switching times. In motor and generator applications, the fast switching times of pulse width modulated (PWM) inverters lead to overvoltages caused by voltage reflections with shorter and shorter cables. These excessive overvoltages may lead to a failure of the electrical machine in a matter of months. In this thesis, the causes behind the overvoltage phenomenon as well as its different mitigation techniques are studied. The most suitable techniques for mitigating the overvoltage phenomenon in wind power generator applications are chosen based on both simulations and actual measurements performed on a prototype. An RC filter at the terminals of the electrical machine and an inverter output filter designed to reduce the rise and fall times of voltage pulses are presented as a solution to the overvoltage problem. The performance and losses of both filter types are analysed.
Resumo:
In the present work electroluminescence in Si-SiO2 structures has been investigated. Electroluminescence has been recorded in the range of 250-900 nm in a system of electrolyte-insulator-semiconductor at the room temperature. The heating process of electrons in SiO2 was studied and possibility of separation it into two phases has been shown. The nature of luminescence centers and the model of its formation were proposed. This paper also includes consideration of oxide layer formation. Charge transfer mechanisms have been attended as well. The nature of electroluminescence is understood in detail. As a matter of fact, electron traps in silicon are the centers of luminescence. Electroluminescence occurs when electrons move from one trap to another. Thus the radiation of light quantum occurs. These traps appear as a result of the oxide growth. At the same time the bonds deformation of silicon atoms with SiOH groups is not excludes. As a result, dangling bonds are appeared, which are the trapping centers or the centers of luminescence.
Resumo:
This paper describes the construction of an eletrical current source and of a probe to be used in the measurement of eletrical conductivity through a four-point probe method. These pieces of equipments can be obtained at the low price of US$ 50.00 and are adequate for eletrical conductivity measurements in the semiconductor range, that is from 10-1 to 10-6 S cm-1.
Resumo:
A theoretical model for the noise properties of Schottky barrier diodes in the framework of the thermionic-emission¿diffusion theory is presented. The theory incorporates both the noise inducedby the diffusion of carriers through the semiconductor and the noise induced by the thermionicemission of carriers across the metal¿semiconductor interface. Closed analytical formulas arederived for the junction resistance, series resistance, and contributions to the net noise localized indifferent space regions of the diode, all valid in the whole range of applied biases. An additionalcontribution to the voltage-noise spectral density is identified, whose origin may be traced back tothe cross correlation between the voltage-noise sources associated with the junction resistance andthose for the series resistance. It is argued that an inclusion of the cross-correlation term as a newelement in the existing equivalent circuit models of Schottky diodes could explain the discrepanciesbetween these models and experimental measurements or Monte Carlo simulations.
Resumo:
An analytical theory to describe the combined effects of the epitaxial layer thickness and the ohmic contact on the noise properties of Schottky barrier diodes is presented. The theory, which provides information on both the local and the global noise properties, takes into account the finite size of the epitaxial layer and the effects of the back ohmic contact, and applies to the whole range of applied bias. It is shown that by scaling down the epitaxial layer thickness, the current regime in which the noise temperature displays a shot-noise-like behavior increases at the cost of reducing the current range in which the thermal-noise-like behavior dominates. This improvement in noise temperature is limited by the effects of the ohmic contact, which appear for large currents. The theory is formulated on general trends, allowing its application to the noise analysis of other semiconductor devices operating under strongly inhomogeneous distributions of the electric field and charge concentrations.
Resumo:
We present a microscopic analysis of shot-noise suppression due to long-range Coulomb interaction in semiconductor devices under ballistic transport conditions. An ensemble Monte Carlo simulator self-consistently coupled with a Poisson solver is used for the calculations. A wide range of injection-rate densities leading to different degrees of suppression is investigated. A sharp tendency of noise suppression at increasing injection densities is found to scale with a dimensionless Debye length related to the importance of space-charge effects in the structure.