971 resultados para Rf-sputtering


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have studied the current transport and electroluminescence properties of metal oxide semiconductor MOS devices in which the oxide layer, which is codoped with silicon nanoclusters and erbium ions, is made by magnetron sputtering. Electrical measurements have allowed us to identify a Poole-Frenkel conduction mechanism. We observe an important contribution of the Si nanoclusters to the conduction in silicon oxide films, and no evidence of Fowler-Nordheim tunneling. The results suggest that the electroluminescence of the erbium ions in these layers is generated by energy transfer from the Si nanoparticles. Finally, we report an electroluminescence power efficiency above 10−3%. © 2009 American Institute of Physics. doi:10.1063/1.3213386

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä diplomityössä on kehitetty kapeakaistaisten mikroaaltoresonaattoreiden mittaukseen soveltuvaa elektroniikkaa 400 MHz taajuusalueelle. Työn teoriaosuudessa on tutustuttu RF- ja mikroaaltotaajuuksilla käytettävien resonaattoreiden ominaisuuksiin sekä tarkasteltu erilaisia mahdollisia mittauselektroniikkatoteutuksia. Tarkastelujen perusteella on valittu toteutettavan mittauselektroniikan periaate. Toteutettu mittauselektroniikka hyödyntää suoraa digitaalista taajuussynteesiä hyvän taajuusresoluution saavuttamiseksi. Mittauselektroniikkaa on kehitetty prototyyppien avulla. Työssä on myös vertailtu resonaattoreiden mittaustuloksia käytettäessä kehitettyä mittauselektroniikkaa ja piirianalysaattoria. Kehitetyllä mittauselektroniikalla saadut tulokset vastaavat hyvin piirianalysaattorimittauksen tuloksia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present tunneling experiments on Fe~001!/MgO~20 Å!/FeCo~001! single-crystal epitaxial junctions of high quality grown by sputtering and laser ablation. Tunnel magnetoresistance measurements give 60% at 30 K, to be compared with 13% obtained recently on ~001!-oriented Fe/amorphous-Al2O3 /FeCo tunnel junctions. This difference demonstrates that the spin polarization of tunneling electrons is not directly related to the density of states of the free metal surface Fe~001! in this case but depends on the actual electronic structure of the entire electrode/barrier system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityössä tarkasteltiin antennien säteilykuviomittauksiin käytettävien antennimittaratojen ominaisuuksia. Sovelletun elektroniikan laboratorion antennimittaradasta kehitettiin toimiva säteilykuvion mittausjärjestelmä, johon kuuluvat radiokaiuton kammio, suuntauskoneisto ja antennikannakkeet, HP 8720D -piirianalysaattori ja RF-kaapelointi sekä valmistutetut mitta-antennitorvet. Työssä vertailtiin koaksiaalikaapeleita ja valittiin antennimittaukseen soveltuvat. 1,70–2,60 GHz:n taajuusalueen mittastandardiksi suunniteltiin torviantenni, jonka kaksi prototyyppiä valmistutettiin konetekniikan osastolla. Torviantennien ominaisuudet mitattiin. Antennimittaradan ominaisuudet ja soveltuvuus erilaisiin antennimittauksiin selvitettiin sekä teoreettisesti että mittauksin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to determine the number of measurements necessary to evaluate physical and chemical characteristics of peach fruits, study the relationships between them and their direct and indirect effects on the content of ascorbic acid and total carotenoids. The characteristics skin and pulp color, fruit weight, suture, equatorial and polar diameters, firmness, soluble solids (SS), titratable acidity (TA), SS/TA ratio, ascorbic acid and total carotenoids were evaluated in 39 cultivars of peach and 3 cultivars of nectarine from the orchard of the Universidade Federal de Viçosa. The repeatability coefficient was estimated by ANOVA and CPCOR. Phenotypic correlation coefficients (rf) were estimated and, after the multicollinearity diagnostics, they were unfolded to direct and indirect effects of the explanatory variables on the response variable using path analysis. There was agreement on the magnitude of repeatability coefficients obtained by the two methods; however, they varied among the 14 characteristics. The highest correlations were found between FW, SD, ED and PD. Seven fruits are sufficient to evaluate the physical and chemical characteristics of peach with a correlation coefficient of 90%. The characteristics considered in the path diagrams (b* skin, hº skin, b* pulp, hº pulp, ED, PD, FIR, SS, SS/AT and TC) are not the main determinants of the ascorbic acid. The yellow hue of the pulp (hº pulp) has the potential to be used in indirect selection for total carotenoids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Opinnäytetyön aiheena oli betuliinijohdannaiset. Tavoitteena oli tehdä synteesisarja, jossa betuliiniin ja betulonihappoon liitettiin esteröintireaktiolla erilaisia happoja, terpeenialkoholeja ja fenoleja. Lisäksi tavoitteena oli saada selvyys bioaktiivisista ominaisuuksista ja mahdollisista muista soveltuvuuksista. Työ tehtiin osana VTT:n Kuori- tutkimusprojektia, jossa betuliinille ja muille puiden kuori- ja uuteaineille pyritään löytämään kaupallisia käyttökohteita esimerkiksi lääkeaineina, pestisideinä ja kosmetiikka-alan raaka-aineina. Betuliini on pentasyklinen triterpeenialkoholi, jota saadaan eristettyä varsin tehokkaasti koivun kuoresta ja tuohesta uuttamalla. Betuliinilla ja sen johdannaisilla on todistettu olevan useita lääkinnällisiä vaikutuksia kuten esimerkiksi tulehduksia estäviä, antiviraalisia, antimalaarisia, antitumoraalisia sekä anti-HIV-aktiivisuutta. Betuliinissa, lup-20(29)-ene-3β,28-diolissa, on käytännössä kolme reaktiivista ryhmää, primäärinen hydroksyyliryhmä hiilessä 28, sekundäärinen hydroksyyliryhmä hiilessä 3 sekä alkeenirakenne hiilessä 20, joista jokaisen ryhmän reaktioilla voidaan helposti saada aikaan betuliinijohdannaisia. Betuliinin ja betulonihapon reaktioihin valittiin erilaisia esteröintimenetelmiä, joissa katalyytteinä käytettiin mm. p-tolueenisulfonihappoa, titaani(IV)isopropylaattia, N,N-dimetyyli-4-aminopyridiini ja N-(3-dimetyyliaminopropyyli)-N-etyylikarbodiimidihydroklori-dia. Synteesituotteiden puhdistusmenetelminä käytettiin uudelleen kiteyttämistä ja pylväskromatografiaa. Synteesituotteet analysoitiin NMR:llä, GC-MS:llä, IR-spektrometrillä ja alkuaineanalyysillä. Lisäksi reaktiotuotteista mitattiin sulamispisteet ja Rf-arvot. Synteesisarjaan suunnitelluista betuliini- ja betulonihappojohdannaisista onnistuivat betuliini-28-ferulihappoesteri, betulonihappo-28-vaniliiniesteri ja betulonihappo-28-karva-kroliesteri. Tuotteille on tehty ja tullaan tekemään erilaisia bioaktiivisuustestejä ja näin ollen kaikkia tuloksia ei ole vielä saatu. Osassa testeistä kyseiset tuotteet ovat osoittautuneet jo lievästi aktiivisiksi, joten kyseisten tuotteiden testaamista sekä betuliiniin ja sen johdannaisiin liittyvää syntetiikkaa ja tutkimustyötä kannattaa ehdottomasti jatkaa, koska betuliinijohdannaisilla voi olla ratkaiseva merkitys esimerkiksi sairauksien hoidossa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Given their high sensitivity and ability to limit the field of view (FOV), surface coils are often used in magnetic resonance spectroscopy (MRS) and imaging (MRI). A major downside of surface coils is their inherent radiofrequency (RF) B1 heterogeneity across the FOV, decreasing with increasing distance from the coil and giving rise to image distortions due to non-uniform spatial responses. A robust way to compensate for B1 inhomogeneities is to employ adiabatic inversion pulses, yet these are not well adapted to all imaging sequences - including to single-shot approaches like echo planar imaging (EPI). Hybrid spatiotemporal encoding (SPEN) sequences relying on frequency-swept pulses provide another ultrafast MRI alternative, that could help solve this problem thanks to their built-in heterogeneous spatial manipulations. This study explores how this intrinsic SPEN-based spatial discrimination, could be used to compensate for the B1 inhomogeneities inherent to surface coils. Experiments carried out in both phantoms and in vivo rat brains demonstrate that, by suitably modulating the amplitude of a SPEN chirp pulse that progressively excites the spins in a direction normal to the coil, it is possible to compensate for the RF transmit inhomogeneities and thus improve sensitivity and image fidelity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with the structural properties of a-Si:H/a-Si1-xCx: H multilayers deposited by glow-discharge decomposition of SiH4 and SiH4 and CH4 mixtures. The main feature of the rf plasma reactor is an automated substrate holder. The plasma stabilization time and its influence on the multilayer obtained is discussed. A series of a-Si:H/a-Si1-xCx: H multilayers has been deposited and characterized by secondary ion mass spectrometry (SIMS), X-ray diffraction (XRD) and transmission electron microscopy (TEM). No asymmetry between the two types of interface has been observed. The results show that the multilayers present a very good periodicity and low roughness. The difficulty of determining the abruptness of the multilayer at the nanometer scale is discussed.