975 resultados para Physical unclonable function


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart Material Interface (SMI) is the latest generation of user interface that makes use of engineered materials and leverages their special properties. SMIs are capable of changing their physical properties such as shape, size and color, and can be controlled under certain (external) conditions. We provide an example of such an SMI in the form of a prototype of a vacuum cleaner. The prototype uses schematic electrochromic polymer at the suction nozzle of the vacuum cleaner, which changes its color depending on the dust level on a floor. We emphasize on the new affordances and communication language supported by SMIs, which challenges the current metaphors of user interfaces in the field of HCI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Physical activity after breast cancer diagnosis is associated with improved survival. This study examines levels of and changes in physical activity following breast cancer diagnosis, overall and by race. Methods: The Carolina Breast Cancer Study, Phase III, assessed pre- and post-diagnosis physical activity levels in a cohort of 1,735 women, aged 20-74, diagnosed with invasive breast cancer between 2008 and 2011 in 44 counties of North Carolina. Logistic regression and analysis of variance were used to examine whether demographic, behavioral and clinical characteristics were associated with activity levels. Results: Only 35% of breast cancer survivors met current physical activity guidelines post-diagnosis. A decrease in activity following diagnosis was reported by 59% of patients, with the average study participant reducing their activity by 230 minutes (95% CI: 190, 270). Following adjustment for potential confounders, when compared to white women, African-American women were less likely to meet national physical activity guidelines post-diagnosis (odds ratio: 1.38, 95% CI: 1.01, 1.88), reported less weekly post-diagnosis physical activity (182 vs. 215 minutes; p=0.13), and reported higher average reductions in pre- versus post-diagnosis weekly activity (262 vs. 230 minutes; p-value = 0.13). Conclusion: Despite compelling evidence demonstrating the benefits of physical activity post-breast cancer, it is clear that more work needs to be done to promote physical activity in breast cancer patients, especially among African-American women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A key derivation function (KDF) is a function that transforms secret non-uniformly random source material together with some public strings into one or more cryptographic keys. These cryptographic keys are used with a cryptographic algorithm for protecting electronic data during both transmission over insecure channels and storage. In this thesis, we propose a new method for constructing a generic stream cipher based key derivation function. We show that our proposed key derivation function based on stream ciphers is secure if the under-lying stream cipher is secure. We simulate instances of this stream cipher based key derivation function using three eStream nalist: Trivium, Sosemanuk and Rabbit. The simulation results show these stream cipher based key derivation functions offer efficiency advantages over the more commonly used key derivation functions based on block ciphers and hash functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Since 1992 there have been several articles published on research on plastic scintillators for use in radiotherapy. Plastic scintillators are said to be tissue equivalent, temperature independent and dose rate independent [1]. Although their properties were found to be promising for measurements in megavoltage X-ray beams there were some technical difficulties with regards to its commercialisation. Standard Imaging has produced the first commercial system which is now available for use in a clinical setting. The Exradin W1 scintillator device uses a dual fibre system where one fibre is connected to the Plastic Scintillator and the other fibre only measures Cerenkov radiation [2]. This paper presents results obtained during commissioning of this dosimeter system. Methods All tests were performed on a Novalis Tx linear accelerator equipped with a 6 MV SRS photon beam and conventional 6 and 18 MV X-ray beams. The following measurements were performed in a Virtual Water phantom at a depth of dose maximum. Linearity: The dose delivered was varied between 0.2 and 3.0 Gy for the same field conditions. Dose rate dependence: For this test the repetition rate of the linac was varied between 100 and 1,000 MU/min. A nominal dose of 1.0 Gy was delivered for each rate. Reproducibility: A total of five irradiations for the same setup. Results The W1 detector gave a highly linear relationship between dose and the number of Monitor Units delivered for a 10 9 10 cm2 field size at a SSD of 100 cm. The linearity was within 1 % for the high dose end and about 2 % for the very low dose end. For the dose rate dependence, the dose measured as a function of repetition the rate (100–1,000 MU/min) gave a maximum deviation of 0.9 %. The reproducibility was found to be better than 0.5 %. Discussion and conclusions The results for this system look promising so far being a new dosimetry system available for clinical use. However, further investigation is needed to produce a full characterisation prior to use in megavoltage X-ray beams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The consistency of measuring small field output factors is greatly increased by reporting the measured dosimetric field size of each factor, as opposed to simply stating the nominal field size [1] and therefore requires the measurement of cross-axis profiles in a water tank. However, this makes output factor measurements time consuming. This project establishes at which field size the accuracy of output factors are not affected by the use of potentially inaccurate nominal field sizes, which we believe establishes a practical working definition of a ‘small’ field. The physical components of the radiation beam that contribute to the rapid change in output factor at small field sizes are examined in detail. The physical interaction that dominates the cause of the rapid dose reduction is quantified, and leads to the establishment of a theoretical definition of a ‘small’ field. Methods Current recommendations suggest that radiation collimation systems and isocentre defining lasers should both be calibrated to permit a maximum positioning uncertainty of 1 mm [2]. The proposed practical definition for small field sizes is as follows: if the output factor changes by ±1.0 % given a change in either field size or detector position of up to ±1 mm then the field should be considered small. Monte Carlo modelling was used to simulate output factors of a 6 MV photon beam for square fields with side lengths from 4.0 to 20.0 mm in 1.0 mm increments. The dose was scored to a 0.5 mm wide and 2.0 mm deep cylindrical volume of water within a cubic water phantom, at a depth of 5 cm and SSD of 95 cm. The maximum difference due to a collimator error of ±1 mm was found by comparing the output factors of adjacent field sizes. The output factor simulations were repeated 1 mm off-axis to quantify the effect of detector misalignment. Further simulations separated the total output factor into collimator scatter factor and phantom scatter factor. The collimator scatter factor was further separated into primary source occlusion effects and ‘traditional’ effects (a combination of flattening filter and jaw scatter etc.). The phantom scatter was separated in photon scatter and electronic disequilibrium. Each of these factors was plotted as a function of field size in order to quantify how each affected the change in small field size. Results The use of our practical definition resulted in field sizes of 15 mm or less being characterised as ‘small’. The change in field size had a greater effect than that of detector misalignment. For field sizes of 12 mm or less, electronic disequilibrium was found to cause the largest change in dose to the central axis (d = 5 cm). Source occlusion also caused a large change in output factor for field sizes less than 8 mm. Discussion and conclusions The measurement of cross-axis profiles are only required for output factor measurements for field sizes of 15 mm or less (for a 6 MV beam on Varian iX linear accelerator). This is expected to be dependent on linear accelerator spot size and photon energy. While some electronic disequilibrium was shown to occur at field sizes as large as 30 mm (the ‘traditional’ definition of small field [3]), it has been shown that it does not cause a greater change than photon scatter until a field size of 12 mm, at which point it becomes by far the most dominant effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Total scatter factor (or output factor) in megavoltage photon dosimetry is a measure of relative dose relating a certain field size to a reference field size. The use of solid phantoms has been well established for output factor measurements, however to date these phantoms have not been tested with small fields. In this work, we evaluate the water equivalency of a number of solid phantoms for small field output factor measurements using the EGSnrc Monte Carlo code. Methods The following small square field sizes were simulated using BEAMnrc: 5, 6, 7, 8, 10 and 30 mm. Each simulated phantom geometry was created in DOSXYZnrc and consisted of a silicon diode (of length and width 1.5 mm and depth 0.5 mm) submersed in the phantom at a depth of 5 g/cm2. The source-to-detector distance was 100 cm for all simulations. The dose was scored in a single voxel at the location of the diode. Interaction probabilities and radiation transport parameters for each material were created using custom PEGS4 files. Results A comparison of the resultant output factors in the solid phantoms, compared to the same factors in a water phantom are shown in Fig. 1. The statistical uncertainty in each point was less than or equal to 0.4 %. The results in Fig. 1 show that the density of the phantoms affected the output factor results, with higher density materials (such as PMMA) resulting in higher output factors. Additionally, it was also calculated that scaling the depth for equivalent path length had negligible effect on the output factor results at these field sizes. Discussion and conclusions Electron stopping power and photon mass energy absorption change minimally with small field size [1]. Also, it can be seen from Fig. 1 that the difference from water decreases with increasing field size. Therefore, the most likely cause for the observed discrepancies in output factors is differing electron disequilibrium as a function of phantom density. When measuring small field output factors in a solid phantom, it is important that the density is very close to that of water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this study was to evaluate age and gender differences in objectively measured physical activity (PA) in a population-based sample of students in grades 1–12. Methods Participants (185 male, 190 female) wore a CSA 7164 accelerometer for 7 consecutive days. To examine age-related trends, students were grouped as follows: grades 1–3 (N = 90), grades 4–6 (N = 91), grades 7–9 (N = 96), and grades 10–12 (N = 92). Bouts of PA and minutes spent in moderate-to-vigorous PA (MVPA) and vigorous PA (VPA) were examined. Results Daily MVPA and VPA exhibited a significant inverse relationship with grade level, with the largest differences occurring between grades 1–3 and 4–6. Boys were more active than girls; however, for overall PA, the magnitudes of the gender differences were modest. Participation in continuous 20-min bouts of PA was low to nonexistent. Conclusion Our results support the notion that PA declines rapidly during childhood and adolescence and that accelerometers are feasible alternatives to self-report methods in moderately sized population-level surveillance studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To review and update the evidence relating to the personal, social, and environmental factors associated with physical activity (PA) in adults. Methods Systematic review of the peer-reviewed literature to identify papers published between 1998 and 2000 with PA (and including exercise and exercise adherence). Qualitative reports or case studies were not included. Results Thirty-eight new studies were located. Most confirmed the existence of factors already known to be correlates of PA. Changes in status were noted in relation to the influence of marital status, obesity, smoking, lack of time, past exercise behavior, and eight environmental variables. New studies were located which focused on previously understudied population groups such as minorities, middle and older aged adults, and the disabled. Conclusion The newly reported studies tend to take a broader “ecological” approach to understanding the correlates of PA and are more focused on environmental factors. There remains a need to better understand environmental influences and the factors that influence different types of PA. As most of the work in this field still relies on cross-sectional studies, longitudinal and intervention studies will be required if causal relationships are to be inferred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To test a conceptual model linking parental physical activity orientations, parental support for physical activity, and children's self-efficacy perceptions with physical activity participation. Participants and setting The sample consisted of 380 students in grades 7 through 12 (mean age, 14.0±1.6 years) and their parents. Data collection took place during the fall of 1996. Main outcome measures Parents completed a questionnaire assessing their physical activity habits, enjoyment of physical activity, beliefs regarding the importance of physical activity, and supportive behaviors for their child's physical activity. Students completed a 46-item inventory assessing physical activity during the previous 7 days and a 5-item physical activity self-efficacy scale. The model was tested via observed variable path analysis using structural equation modeling techniques (AMOS 4.0). Results An initial model, in which parent physical activity orientations predicted child physical activity via parental support and child self-efficacy, did not provide an acceptable fit to the data. Inclusion of a direct path from parental support to child physical activity and deletion of a nonsignificant path from parental physical activity to child physical activity significantly improved model fit. Standardized path coefficients for the revised model ranged from 0.17 to 0.24, and all were significant at the p<0.0001 level. Conclusions Parental support was an important correlate of youth physical activity, acting directly or indirectly through its influence on self-efficacy. Physical activity interventions targeted at youth should include and evaluate the efficacy of individual-level and community-level strategies to increase parents’ capacity to provide instrumental and motivational support for their children's physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To review the effects of physical activity on health and behavior outcomes and develop evidence-based recommendations for physical activity in youth. Study design A systematic literature review identified 850 articles; additional papers were identified by the expert panelists. Articles in the identified outcome areas were reviewed, evaluated and summarized by an expert panelist. The strength of the evidence, conclusions, key issues, and gaps in the evidence were abstracted in a standardized format and presented and discussed by panelists and organizational representatives. Results Most intervention studies used supervised programs of moderate to vigorous physical activity of 30 to 45 minutes duration 3 to 5 days per week. The panel believed that a greater amount of physical activity would be necessary to achieve similar beneficial effects on health and behavioral outcomes in ordinary daily circumstances (typically intermittent and unsupervised activity). Conclusion School-age youth should participate daily in 60 minutes or more of moderate to vigorous physical activity that is developmentally appropriate, enjoyable, and involves a variety of activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Obesity rates are increasing among children of all ages, and reduced physical activity is a likely contributor to this trend. Little is known about the physical activity behavior of preschool-aged children or about the influence of preschool attendance on physical activity. The purpose of this study was to describe the physical activity levels of children while they attend preschools, to identify the demographic factors that might be associated with physical activity among those children, and to determine the extent to which children's physical activity varies among preschools. Methods A total of 281 children from 9 preschools wore an Actigraph (Fort Walton Beach, FL) accelerometer for an average of 4.4 hours per day for an average of 6.6 days. Each child's height and weight were measured, and parents of participating children provided demographic and education data. Results The preschool that a child attended was a significant predictor of vigorous physical activity (VPA) and moderate-to-vigorous physical activity (MVPA). Boys participated in significantly more MVPA and VPA than did girls, and black children participated in more VPA than did white children. Age was not a significant predictor of MVPA or VPA. Conclusions Children's physical activity levels were highly variable among preschools, which suggests that preschool policies and practices have an important influence on the overall activity levels of the children the preschools serve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the physical activity (PA) patterns and the hypothesized psychosocial and environmental determinants of PA in an ethnically diverse sample of obese and non-obese middle school children. DESIGN Cross-sectional study. SUBJECTS One-hundred and thirty-three non-obese and 54 obese sixth grade children (mean age of 11.4 +/-0.6). Obesity status determined using the age-, race- and gender-specific 95th percentile for BMI from NHANES-1. MEASUREMENTS Objective measurements were collected of PA over a 7-day period using the CSA 7164 accelerometer: total daily counts; daily moderate (3-5.9 METs) physical activity (MPA); daily vigorous physical activity (greater than or equal to 6 METs; VPA); and weekly number of 5, 10 and 20 min bouts of moderate-to-vigorous physical activity (greater than or equal to 3 METs, MVPA). Self-report measures were collected of PA self-efficacy; social influences regarding PA, beliefs about PA outcomes; perceived PA levels of parents and peers, access to sporting and/or fitness equipment at home, involvement in community-based PA organizations; participation in community sports teams; and hours spent watching television or playing video games. RESULTS Compared to their non-obese counterparts, obese children exhibited significantly lower daily accumulations of total counts, MPA and VPA as well as significantly fewer 5, 10 and 20 min bouts of MVPA. Obese children reported significantly lower levels of PA self-efficacy, were involved in significantly fewer community organizations promoting PA and were significantly less likely to report their father or male guardian as physically active. CONCLUSIONS The results are consistent with the hypothesis that physical inactivity is an important contributing factor in the maintenance of childhood obesity. Interventions to promote PA in obese children should endeavor to boost self-efficacy perceptions regarding exercise, increase awareness of, and access to, community PA outlets, and increase parental modeling of PA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate monitoring of prevalence and trends in population levels of physical activity (PA) is a fundamental public health need. Test-retest reliability (repeatability) was assessed in population samples for four self-report PA measures: the Active Australia survey (AA, N=356), the short International Physical Activity Questionnaire (IPAQ, N=104), the physical activity items in the Behavioral Risk Factor Surveillance System (BRFSS, N=127) and in the Australian National Health Survey (NHS, N=122). Percent agreement and Kappa statistics were used to assess reliability of classification of activity status as 'active', 'insufficiently active' or 'sedentary'. Intraclass correlations (ICCs) were used to assess agreement on minutes of activity reported for each item of each survey and for total minutes. Percent agreement scores for activity status were very good on all four instruments, ranging from 60% for the NHS to 79% for the IPAQ. Corresponding Kappa statistics ranged from 0.40 (NHS) to 0.52 (AA). For individual items, ICCs were highest for walking (0.45 to 0.78) and vigorous activity (0.22 to 0.64) and lowest for the moderate questions (0.16 to 0.44). All four measures provide acceptable levels of test-retest reliability for assessing both activity status and sedentariness, and moderate reliability for assessing total minutes of activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the validity and inter-rater reliability of the Observation System for Recording Activity in Children: Youth Sports (OSRAC:YS). Children (N=29) participating in a parks and recreation soccer program were observed during regularly scheduled practices. Physical activity (PA) intensity and contextual factors were recorded by momentary time-sampling procedures (10-sec observe, 20-sec record). Two observers simultaneously observed and recorded children's PA intensity, practice context, social context, coach behavior, and coach proximity. Inter-rater reliability was based on agreement (Kappa) between the observer's coding for each category, and the Intraclass Correlation Coefficient (ICC) for percent of time spent in MVPA. Validity was assessed by calculating the correlation between OSRAC:YS estimated and objectively measured MVPA. Kappa statistics for each category demonstrated substantial to almost perfect inter-observer agreement (Κappa = 0.67 to 0.93). The ICC for percent time in MVPA was 0.76 (95% C.I. = 0.49 - 0.90). A significant correlation (r = 0.73) was observed for MVPA recorded by observation and MVPA measured via accelerometry. The results indicate the OSRAC:YS is a reliable and valid tool for measuring children's PA and contextual factors during a youth soccer practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With measurement of physical activity becoming more common in clinical practice, it is imperative that healthcare professionals become more knowledgeable about the different methods available to objectively measure physical activity behaviour. Objective measures do not rely on information provided by the patient, but instead measure and record the biomechanical or physiological consequences of performing physical activity, often in real time. As such, objective measures are not subject to the reporting bias or recall problems associated with self-report methods. The purpose of this article was to provide an overview of the different methods used to objectively measure physical activity in clinical practice. The review was delimited to heart rate monitoring, accelerometers and pedometers since their small size, low participant burden and relatively low cost make these objective measures appropriate for use in clinical practice settings. For each measure, strengths and weakness were discussed; and whenever possible, literature-based examples of implementation were provided.