971 resultados para PERPENDICULAR ANISOTROPY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

After stroke, white matter integrity can be affected both locally and distally to the primary lesion location. It has been shown that tract disruption in mirror's regions of the contralateral hemisphere is associated with degree of functional impairment. Fourteen patients suffering right hemispheric focal stroke (S) and eighteen healthy controls (HC) underwent Diffusion Weighted Imaging (DWI) and neuropsychological assessment. The stroke patient group was divided into poor (SP; n = 8) and good (SG; n = 6) cognitive recovery groups according to their cognitive improvement from the acute phase (72 hours after stroke) to the subacute phase (3 months post-stroke). Whole-brain DWI data analysis was performed by computing Diffusion Tensor Imaging (DTI) followed by Tract Based Spatial Statistics (TBSS). Assessment of effects was obtained computing the correlation of the projections on TBSS skeleton of Fractional Anisotropy (FA) and Radial Diffusivity (RD) with cognitive test results. Significant decrease of FA was found only in right brain anatomical areas for the S group when compared to the HC group. Analyzed separately, stroke patients with poor cognitive recovery showed additional significant FA decrease in several left hemisphere regions; whereas SG patients showed significant decrease only in the left genu of corpus callosum when compared to the HC. For the SG group, whole brain analysis revealed significant correlation between the performance in the Semantic Fluency test and the FA in the right hemisphere as well as between the performance in the Grooved Pegboard Test (GPT) and theTrail Making Test-part A and the FA in the left hemisphere. For the SP group, correlation analysis revealed significant correlation between the performance in the GPT and the FA in the right hemisphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on the paraxial vectorial theory of beams propagating in uniaxially anisotropic media, we have derived the analytical propagation equations of hollow Gaussian beams (HGBs) in uniaxial crystals, and given the typical numerical example to illustrate our analytical results. Due to the anisotropy crystals, the ordinary and extraordinary beams originated by incident HGBs propagate with different diffraction lengths, thus the linear polarization state and axial symmetry of incident HGBs do not remain during propagating in crystals. (c) 2007 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

倾斜沉积是一种新型的薄膜沉积技术。通过制备过程中基片的旋转和倾斜,可以制备出斜柱状、之字形、螺旋状、S形以及C形等各种形状的雕塑薄膜。雕塑薄膜可以实现许多传统薄膜无法实现的光学性质,为光学薄膜的设计与制备开辟了新的途径。本文综述了雕塑薄膜的制备方法,分析了雕塑薄膜的结构特征及影响因素,并阐述了其在光学领域的广泛应用前景。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the preparation and the characterization Of Y2O3 stabilized ZrO2 thin films produced by electric-beam evaporation method. The optical properties, microstructure, surface morphology and the residual stress of the deposited films were investigated by optical spectroscopy, X-ray diffraction (XRD), scanning probe microscope and optical interferometer. It is shown that the optical transmission spectra of all the YSZ thin films are similar with those of ZrO2 thin film, possessing high transparency in the visible and near-infrared regions. The refractive index of the samples decreases with increasing of Y2O3 content. The crystalline structure of pure ZrO2 films is a mixture of tetragonal phase and monoclinic phase, however, Y2O3 stabilized ZrO2 thin films only exhibit the cubic phase independently of how much the added Y2O3 content is. The surface morphology spectrum indicates that all thin films present a crystalline columnar texture with columnar grains perpendicular to the substrate and with a predominantly open microporosity. The residual stress of films transforms tensile from compressive with the increasing Of Y2O3 molar content, which corresponds to the evolutions of the structure and packing densities. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nb2O5 sculptured thin. films deposited by electron beam evaporation with glancing angle deposition were prepared. Nb2O5 sculptured thin. films with tilted columns are optical anisotropy. XRD, SEM, UV-vis-NIR spectra are employed to characterize the microstructure and optical properties. The maximum of birefringence (Delta n) is up to 0.045 at alpha = 70 degrees with packing density of 0.487. With increasing the deposition angle, refractive index and packing density of Nb2O5 STF are decreasing. The relationship among deposition parameter, microstructure and optical properties was investigated in detail. (C) 2008 Elsevier B. V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates the optical properties and microstructure of Ta2O5 film deposited with the glancing angle deposition technique. The tilted nanocolumn microstructure, examined with scanning electron microscopy, induces the optical anisotropy of thin film. The optical properties of thin film are characterized with an inverse synthesis method. Based on the Cauchy model, the dispersion equations of optical constants of film are determined from the transmittance spectra measured at normal and oblique incidence over 400-800 nm. The starting values derived with an envelope method quicken the optimization process greatly. The dispersion of the principal indices N-1, N-2, and N-3 and the thickness d of thin film are presented statistically. A good agreement between the measured optical properties and theoretical calculation is obtained, which validates the model established for thin film produced by glancing angle deposition. (C) 2008 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho, os efeitos de um campo magnético oblíquo externo no modelo de Gross- Neveu (2+1)-dimensional, que inclui as componentes paralela e perpendicular do campo em relação ao sistema, são estudados no contexto da simetria quiral e discreta do modelo. Nosso principal interesse está nos efeitos deste campo sobre o diagrama de fase do sistema, onde também incluímos os efeitos combinados de temperatura e potencial químico. Os diagramas de fase são obtidos através do potencial efetivo a 1 loop para o modelo, derivado em primeira ordem na expansão 1=N. Transições de fase relevantes que podem ser estudadas através deste modelo são, por exemplo, metal-isolante em matéria condensada e na teoria quântica de campos de férmions planares em geral. A relação entre a transição de fase com quebra da simetria quiral e discreta e o surgimento de um gap (ou a presença de um valor esperado no vácuo do campo escalar diferente de zero), como função do campo magnético oblíquo, é analisada em detalhes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O efeito magnetocalórico, base da refrigeração magnética, é caracterizado por duas quantidades: a variação isotérmica da entropia (ΔST) e a variação adiabática da temperatura (ΔTad) as quais podem ser obtidas sob variações na intensidade de um campo magnético aplicado. Em sistemas que apresentam anisotropia magnética, pode‐se definir o efeito magnetocalórico anisotrópico, o qual, por definição, é calculado através da variação na direção de aplicação de um campo magnético cuja intensidade se mantém fixa. Nos materiais de nosso interesse, o efeito magnetocalórico é estudado teoricamente partindo de um hamiltoniano modelo que leva em conta a rede magnética (que pode ser composta por diversas sub-redes magnéticas acopladas), rede cristalina e a dinâmica dos elétrons de condução. No hamiltoniano magnético são consideradas as interações de troca, Zeeman e campo cristalino (esta ultima responsável pela anisotropia magnética). Recentemente, estudamos o efeito magnetocalórico convencional e o efeito magnetocalórico anisotrópico nos compostos mononitretos com terras-raras, a saber: Ho(y)Er(1-y)N para as concentrações y= 0,1,0.5 e 0.75. Comparações entre nossos resultados teóricos e os dados experimentais para o EMC foram bastante satisfatórias [3,9]. Além disso, diversas predições teóricas como a existência de uma fase ferrimagnética no sistema Ho(y)Er(1-y)N (para a concentração y=0.5) e reorientações de spin nas sub-redes do Ho e Er foram feitas [25].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the VITAL cruise in the Bay of Biscay in summer 2002, two devices for measuring the length of swimming fish were tested: 1) a mechanical crown that emitted a pair of parallel laser beams and that was mounted on the main camera and 2) an underwater auto-focus video camera. The precision and accuracy of these devices were compared and the various sources of measurement errors were estimated by repeatedly measuring fixed and mobile objects and live fish. It was found that fish mobility is the main source of error for these devices because they require that the objects to be measured are perpendicular to the field of vision. The best performance was obtained with the laser method where a video-replay of laser spots (projected on fish bodies) carrying real-time size information was used. The auto-focus system performed poorly because of a delay in obtaining focus and because of some technical problems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho foram estudadas as propriedades estruturais e termomagnéticas dos pseudobinários Ho1-yGdyAl2, através de abordagens experimentais e teóricas. A parte experimental envolveu a preparação de cinco amostras, com as concentrações y = 0, 0,25, 0,5, 0,75 e 1, assim como medidas de magnetização, calor especifico e da variação adiabática da temperatura. Na parte teórica usamos um hamiltoniano modelo que leva em consideração a interação dos íons com o campo magnético aplicado, com o campo elétrico cristalino e a troca entre os íons magnéticos. A entropia da rede foi considerada na aproximação de Debye e a entropia eletrônica na aproximação do gás de elétrons livres. A influência das reorientações de spin, espontâneas e induzidas pelo campo magnético, na magnetização e no calor especifico foram investigadas sistematicamente tanto a partir de dados experimentais quanto teoricamente. Também obtemos resultados teóricos para a variação de entropia e variação adiabática da temperatura alterando a intensidade ou a direção do campo magnético.