985 resultados para Objective Monitoring
Resumo:
Introduction: Imatinib trough plasma concentrations (Cmin) have been correlated with treatment response in chronic myeloid leukemia (CML) patients. The use of Cmin monitoring for optimizing imatinib dosage (therapeutic drug monitoring [TDM]) is therefore proposed for patients with unsatisfying response or tolerance ("rescue TDM"). A cycle of "routine TDM" for dosage individualization could also be beneficial to prevent unfavorable events, yet its clinical usefulness has not been evaluated. We aimed to assess prospectively whether a "routine TDM" intervention targeting imatinib Cmin of 1000 ng/mL (tolerance, 750-1500 ng/mL) could improve efficacy, tolerance, and persistence on treatment compared with "rescue TDM" use only. Patients (or Materials) and Methods: The Swiss Imatinib COncentration Monitoring Evaluation (I-COME) study was a multicenter randomized controlled trial (ISRCTN31181395). Adult patients in chronic or accelerated phase CML receiving imatinib ≤5 years were eligible. Patients were randomly (1:1) allocated to receive "routine TDM" intervention or to serve as controls with access only to "rescue TDM". All had 1-year follow-up. The primary endpoint was a combined efficacy-safety outcome (failure- and toxicity-free survival without imatinib discontinuation), analyzed in intention-to-treat. Results: Among 56 CML recruited patients, 55 had their molecular and cytogenetic response measured. 14/27 of patients receiving "routine TDM" (52% [33%-71%]) remained event-free versus 16/28 of control patients with "rescue TDM" only (57% [39%-75%]; P=0.69). In the "routine TDM" group, dosage recommendations were adopted entirely in 50% of patients (median Cmin at study end, 895 ng/mL; CV = 33%). These patients had fewer unfavorable events (28% [5%-52%]) compared with patients not receiving the advised dosage (77% [54%-99%]; P = 0.03; median Cmin at study end, 648 ng/mL; CV = 38%). Conclusion: This first prospective target concentration intervention trial could not formally demonstrate a benefit of "routine TDM" of imatinib, especially due to a small patient number and limited prescriber's adherence to dosage recommendations. Nevertheless, the patients receiving the advised dosage more often met target concentrations and the combined outcome (efficacy, tolerance, and persistence). A cycle of routine TDM could thus be favorable, at least in patients eligible for dosage adjustment. Its usefulness should, however, be further confirmed in larger trials.
Resumo:
OBJECTIVE: To study the relationship between the energy expenditure for activity (EEAct), the level of activity and adiposity in a group of 9-year-old boys (n = 28) with different body composition (body weight, 38 +/- 10 kg [range, 23 to 66 kg]; fat mass, 23% +/- 10% [range, 8% to 42%]). METHODS: Total energy expenditure (TEE) was measured by means of the heart-rate monitoring method. EEAct was calculated as TEE-(REE+0.1 TEE), where REE is the postabsorptive resting energy expenditure and 0.1 TEE corresponds to the postprandial thermogenesis (approximately 10% of TEE). RESULTS: TEE, REE, and EEAct were 9388 +/- 1859, 5154 +/- 642, and 3295 +/- 1356 l J/day, respectively. Daily time devoted to sedentary and nonsedentary activities averaged 290 +/- 155 minutes (range, 69 to 621) and 534 +/- 150 minutes (range, 180 to 783), respectively. Time spent on sedentary activities was directly proportional to fat mass percentage (r = 0.46; p < 0.05). It was the only variable, among the free-living physical-activity [EEAct, TEE/(REE+0.1 TEE) ratio, time spent in nonsedentary and sedentary activities] variables, which remained significantly in the multiple step-down regression analysis final equation (r = 0.46; p < 0.05). CONCLUSIONS: The positive relationship between adiposity and time spent on sedentary activities in 9-year-old boys suggests the importance of the role played by muscular activity, at least in the maintenance of obesity in childhood. Prepubertal children should be encouraged to spend less time on sedentary activities to treat and prevent their obesity.
Resumo:
Several population pharmacokinetic (PPK) analyses of the anticancer drug imatinib have been performed to investigate different patient populations and covariate effects. The present analysis offers a systematic qualitative and quantitative summary and comparison of those. Its primary objective was to provide useful information for evaluating the expectedness of imatinib plasma concentration measurements in the frame of therapeutic drug monitoring. The secondary objective was to review clinically important concentration-effect relationships to provide help in evaluating the potential suitability of plasma concentration values. Nine PPK models describing total imatinib plasma concentration were identified. Parameter estimates were standardized to common covariate values whenever possible. Predicted median exposure (Cmin) was derived by simulations and ranged between models from 555 to 1388 ng/mL (grand median: 870 ng/mL and interquartile "reference" range: 520-1390 ng/mL). Covariates of potential clinical importance (up to 30% change in pharmacokinetic predicted by at least 1 model) included body weight, albumin, α1 acid glycoprotein, and white blood cell count. Various other covariates were included but were statistically not significant or seemed clinically less important or physiologically controversial. Concentration-response relationships had more importance below the average reference range and concentration-toxicity relationships above. Therapeutic drug monitoring-guided dosage adjustment seems justified for imatinib, but a formal predictive therapeutic range remains difficult to propose in the absence of prospective target concentration intervention trials. To evaluate the expectedness of a drug concentration measurement in practice, this review allows comparison of the measurement either to the average reference range or to a specific range accounting for individual patient characteristics. For future research, external PPK model validation or meta-model development should be considered.
Resumo:
OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Resumo:
Given that clay-rich landslides may become mobilized, leading to rapid mass movements (earthflows and debris flows), they pose critical problems in risk management worldwide. The most widely proposed mechanism leading to such flow-like movements is the increase in water pore pressure in the sliding mass, generating partial or complete liquefaction. This solid-to-liquid transition results in a dramatic reduction of mechanical rigidity in the liquefied zones, which could be detected by monitoring shear wave velocity variations. With this purpose in mind, the ambient seismic noise correlation technique has been applied to measure the variation in the seismic surface wave velocity in the Pont Bourquin landslide (Swiss Alps). This small but active composite earthslide-earthflow was equipped with continuously recording seismic sensors during spring and summer 2010. An earthslide of a few thousand cubic meters was triggered in mid-August 2010, after a rainy period. This article shows that the seismic velocity of the sliding material, measured from daily noise correlograms, decreased continuously and rapidly for several days prior to the catastrophic event. From a spectral analysis of the velocity decrease, it was possible to determine the location of the change at the base of the sliding layer. These results demonstrate that ambient seismic noise can be used to detect rigidity variations before failure and could potentially be used to predict landslides.
Resumo:
BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.
Resumo:
As in cancer biology, in wound healing there is a need for objective staging systems to decide for the best treatment and predictors of outcome. We developed in the diabetic (db/db) wound healing model, a staging system, the "wound watch," based on the quantification of angiogenesis and cell proliferation in open wounds. In chronic wounds, there is often a lack of cellular proliferation and angiogenesis that leads to impaired healing. The wound watch addresses this by quantifying the proliferative phase of wound healing in two dimensions (cellular division and angiogenesis). The results are plotted in a two-dimensional graph to monitor the course of healing and compare the response to different treatments.
Resumo:
OBJECTIVE: Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS: We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mannheim, Germany) in lean (n=15) and obese (n=11) patients. RESULTS: No difference was found in diastolic BP between the two groups, nor between the arm and the wrist. Systolic BP measured at the arm was, however, significantly lower in obese (99+/-9 mmHg, mean+/-SD) than in lean (107+/-14 mmHg; P<0.001) patients, whereas systolic BP determined at the wrist averaged 106 mmHg in both groups. CONCLUSION: The use of validated wrist BP measuring devices appears therefore particularly appealing in obese individuals with a large arm circumference
Resumo:
Introduction Pediatric intensive care patient represent a population athigh risk for drug-related problems. Our objective is to describe drugrelated problems and intervention of four decentralized pharmacists inpediatric and cardiac intensive care unit.Materials & Methods Multicentric, descriptive and prospectivestudy over a six-month period (August 1st 2009-January 31st 2010).Drug-related problems and clinical interventions were compiled infour pediatric centers using a tool developed by the Socie´te´ Franc¸aisede Pharmacie Clinique. Data concerning patients, drugs, intervention,documentation, approval (if needed), and estimated impact werecompiled. The four pharmacists participating were from Belgium (B),France (F), Quebec (Q) and Switzerland (S).Results A total of 996 interventions were collected: 129 (13%) in B,238 (24%) in F, 278 (28%) in Q and 351 (35%) in S. These interventionstargeted 269 patients (median 22 month-old, 52% male): 69(26%) in B, 88 (33%) in F, 56 (21%) in Q and in S. These data werecollected during 28 non consecutive days in the clinical unit in B, 59days in F, 42 days in Q and 63 days in S. The main drug-relatedproblems were inappropriate administration technique (293, 29%),untreated indication (254, 25%) and supra therapeutic dosage (106,11%). The pharmacist's interventions concerned mainly administrationmode optimization (223, 22%), dose adjustment (200, 20%) andtherapeutic monitoring (164, 16%). The three major drug classesleading to interventions were anti-infectives for systemic use (233,23%) and alimentary tract and metabolism drugs (218, 22%). Interventionsconcerned mainly residents and all clinical staff (209, 21%).Among the 879 (88%) interventions requiring a physician's approval,731 (83%) were accepted. Interventions were considered as having amoderate (51%) or major (17%) clinical impact. Among the interventionsprovided, 10% were considered to have an economicalpositive impact. Differences and similarities between countries willbe presented at the poster session.Discussion & Conclusion Decentralized pharmacist at patient bedsideis a pre-requisite for pharmaceutical care. There are limitedstudies comparing the activity of clinical pharmacists betweencountries. This descriptive study illustrates the ability of clinicalpharmacist to identify and solve drug-related problems in pediatricintensive care unit in four different francophone countries.
Resumo:
INTRODUCTION: Continuous EEG (cEEG) is increasingly used to monitor brain function in neuro-ICU patients. However, its value in patients with coma after cardiac arrest (CA), particularly in the setting of therapeutic hypothermia (TH), is only beginning to be elucidated. The aim of this study was to examine whether cEEG performed during TH may predict outcome. METHODS: From April 2009 to April 2010, we prospectively studied 34 consecutive comatose patients treated with TH after CA who were monitored with cEEG, initiated during hypothermia and maintained after rewarming. EEG background reactivity to painful stimulation was tested. We analyzed the association between cEEG findings and neurologic outcome, assessed at 2 months with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). RESULTS: Continuous EEG recording was started 12 ± 6 hours after CA and lasted 30 ± 11 hours. Nonreactive cEEG background (12 of 15 (75%) among nonsurvivors versus none of 19 (0) survivors; P < 0.001) and prolonged discontinuous "burst-suppression" activity (11 of 15 (73%) versus none of 19; P < 0.001) were significantly associated with mortality. EEG seizures with absent background reactivity also differed significantly (seven of 15 (47%) versus none of 12 (0); P = 0.001). In patients with nonreactive background or seizures/epileptiform discharges on cEEG, no improvement was seen after TH. Nonreactive cEEG background during TH had a positive predictive value of 100% (95% confidence interval (CI), 74 to 100%) and a false-positive rate of 0 (95% CI, 0 to 18%) for mortality. All survivors had cEEG background reactivity, and the majority of them (14 (74%) of 19) had a favorable outcome (CPC 1 or 2). CONCLUSIONS: Continuous EEG monitoring showing a nonreactive or discontinuous background during TH is strongly associated with unfavorable outcome in patients with coma after CA. These data warrant larger studies to confirm the value of continuous EEG monitoring in predicting prognosis after CA and TH.