968 resultados para MULTIPLE-ELECTRON-CAPTURE
Resumo:
Through an analysis using the transfer function of a pinhole camera, the multiple imaging characteristics of photographic diffusers described by Grover and Tremblay [Appl. Opt.21,4500(1982)] is studied. It is found that only one pinhole diameter satisfies the optimum imaging condition for best contrast transfer at any desired spatial frequency. A simple method of generating random pinhole arrays with a controlled pinhole diameter is described. These pinhole arrays are later used to generate high frequency sinusoidal gratings from a coarse grid. The contrast in the final gratings is found to be reasonably high.
Resumo:
A pin-on-disc machine was used to wear Al-Si alloy pins under dry conditions. Unmodified and modified binary alloys and commercial multi-component alloys were tested. The surfaces of the worn alloys were examined by scanning electron microscopy to identify distinct topographical features to aid elucidation of the mechanisms of wear.
Resumo:
In a series of experiments conducted in stone fruit orchards in southern Australia, water-based funnel-type traps baited with synthetic aggregation pheromone and fermenting bread dough, trapped 3- to 7-fold as many Carpophihus beetles (primarily C. dauidsoni) than wind-oriented pipe traps or dry funnel traps. The efficacy of dry funnel traps but not pipe traps, appeared to be improved by using water-filled collecting bottles. The potential for using water-based funnel traps in population suppression of Carpophilus spp. in stone fruit orchards through mass trapping is discussed.
Resumo:
This study aims to help broaden the use of electronic portal imaging devices (EPIDs) for pre-treatment patient positioning verification, from photon-beam radiotherapy to photon- and electron-beam radiotherapy, by proposing and testing a method for acquiring clinicallyuseful EPID images of patient anatomy using electron beams, with a view to enabling and encouraging further research in this area. EPID images used in this study were acquired using all available beams from a linac configured to deliver electron beams with nominal energies of 6, 9, 12, 16 and 20 MeV, as well as photon beams with nominal energies of 6 and 10 MV. A widely-available heterogeneous, approximately-humanoid, thorax phantom was used, to provide an indication of the contrast and noise produced when imaging different types of tissue with comparatively realistic thicknesses. The acquired images were automatically calibrated, corrected for the effects of variations in the sensitivity of individual photodiodes, using a flood field image. For electron beam imaging, flood field EPID calibration images were acquired with and without the placement of blocks of water-equivalent plastic (with thicknesses approximately equal to the practical range of electrons in the plastic) placed upstream of the EPID, to filter out the primary electron beam, leaving only the bremsstrahlung photon signal. While the electron beam images acquired using a standard (unfiltered) flood field calibration were observed to be noisy and difficult to interpret, the electron beam images acquired using the filtered flood field calibration showed tissues and bony anatomy with levels of contrast and noise that were similar to the contrast and noise levels seen in the clinically acceptable photon beam EPID images. The best electron beam imaging results (highest contrast, signal-to-noise and contrast-to-noise ratios) were achieved when the images were acquired using the higher energy electron beams (16 and 20 MeV) when the EPID was calibrated using an intermediate (12 MeV) electron beam energy. These results demonstrate the feasibility of acquiring clinically-useful EPID images of patient anatomy using electron beams and suggest important avenues for future investigation, thus enabling and encouraging further research in this area. There is manifest potential for the EPID imaging method proposed in this work to lead to the clinical use of electron beam imaging for geometric verification of electron treatments in the future.
Resumo:
The work is a report of research on using multiple inverters of Battery Energy Storage Systems with angle droop controllers to share real power in an isolated micro grid system consisting of inertia based Distributed Generation units and variable load. The proposed angle droop control method helps to balance the supply and demand in the micro grid autonomous mode through charging and discharging of the Battery Energy Storage Systems while ensuring that the state of charge of the storage devices is within safe operating conditions. The proposed method is also studied for its effectiveness for frequency control. The proposed control system is verified and its performance validated with simulation software MATLAB/SIMULINK.
Resumo:
A modified DLTS technique is proposed for the direct measurement of capture cross-section of MOS surface states. The nature of temperature and energy dependence σn is inferred from data analysis. Temperature dependence of σn is shown to be consistent with the observed DLTS line shapes.
Resumo:
Farnesoic acid O-methyltransferase (FaMeT) is the enzyme responsible for the conversion of farnesoic acid (FA) to methyl farnesoate (MF) in the final step of MF synthesis. Multiple isoforms of putative FaMeT were isolated from six crustacean species belonging to the families Portunidae, Penaeidae, Scyllaridae and Parastacidae. The portunid crabs Portunus pelagicus and Scylla serrata code for three forms: short, intermediate and long. Two isoforms (short and long) were isolated from the penaeid prawns Penaeus monodon and Fenneropenaeus merguiensis. Two isoforms were also identified in the scyllarid Thenus orientalis and parastacid Cherax quadricarinatus. Putative FaMeT sequences were also amplified from the genomic DNA of P. pelagicus and compared to the putative FaMeT transcripts expressed. Each putative FaMeT cDNA isoform was represented in the genomic DNA, indicative of a multi-gene family. Various tissues from P. pelagicus were individually screened for putative FaMeT expression using PCR and fragment analysis. Each tissue type expressed all three isoforms of putative FaMeT irrespective of sex or moult stage. Protein domain analysis revealed the presence of a deduced casein kinase II phosphorylation site present only in the long isoform of putative FaMeT.
Resumo:
Electron and x-ray diffraction experiments on the metlt-spun Al100−x Fe x (x=14, 18, 25) alloys are carried out. It is observed that all the melt-spun alloys possessing the quasi-crystalline phases have icosahedral point-group symmetry.