986 resultados para Fluorescence Spectroscopy
Resumo:
The concept of a "Superheavy Quasiatom" is discussed. Radiative transition times are compared with the lifetime of the intermediate system, cross sections are calculated within a two-collision model and induced transitions and their anisotropic emission are discussed. Recent experimental and theoretical results are presented from collision systems obtained with I-beams bombarding various heavy targets, giving combined Z-values between 120 and 145. Results include the energy dependence of the peak structure interpreted as M X-rays from superheavy quasiatoms and the anisotropy of X-ray emission referred to the beam direction. The data are discussed within the models available. These cannot explain the streng emission of anisotropic radiation in the X-ray energy range of quasiatomic M X-rays at small bombarding energies.
Resumo:
Femtosecond laser pulses are applied to the study of the dynamics and the pathways of multiphoton-induced ionization, autoionization, and fragmentation of Na_2 in molecular-beam experiments. In particular, we report on first results obtained studying electronic autoionization (leading to Na_2{^+} + {e ^-}) and autoionization-induced fragmentation (leading to Na{^+} + Na + {e ^-}) of a bound doubly excited molecular state. The final continuum states are analyzed by photoelectron spectroscopy and by measuring the mass and the released kinetic energy of the corresponding ionic fragments with a time-of-flight arrangement.
Resumo:
We report time-resolved experiments studying the dynamics of the Na_3 B-X system. Femtosecond pump-probe techniques combined with ion time-of-flight (TOF) and zero kinetic energy (ZEKE) photoelectron spectroscopy allow us to observe the three-dimensional wavepacket motion in the excited Na_3 B state and in the Na_3 X state. The ground state wavepacket is induced by stimulated emission pumping during the pump pulse. The X-state dynamics is dominated by the three vibrational modes of the Na_3. Furthermore we observed pseudorotational wavepacket motion in the B state. We do not observe a fragmentation of the B state within a time interval of 10 ps.
Resumo:
A real-time analysis of renewable energy sources, such as arable crops, is of great importance with regard to an optimised process management, since aspects of ecology and biodiversity are considered in crop production in order to provide a sustainable energy supply by biomass. This study was undertaken to explore the potential of spectroscopic measurement procedures for the prediction of potassium (K), chloride (Cl), and phosphate (P), of dry matter (DM) yield, metabolisable energy (ME), ash and crude fibre contents (ash, CF), crude lipid (EE), nitrate free extracts (NfE) as well as of crude protein (CP) and nitrogen (N), respectively in pretreated samples and undisturbed crops. Three experiments were conducted, one in a laboratory using near infrared reflectance spectroscopy (NIRS) and two field spectroscopic experiments. Laboratory NIRS measurements were conducted to evaluate to what extent a prediction of quality parameters is possible examining press cakes characterised by a wide heterogeneity of their parent material. 210 samples were analysed subsequent to a mechanical dehydration using a screw press. Press cakes serve as solid fuel for thermal conversion. Field spectroscopic measurements were carried out with regard to further technical development using different field grown crops. A one year lasting experiment over a binary mixture of grass and red clover examined the impact of different degrees of sky cover on prediction accuracies of distinct plant parameters. Furthermore, an artificial light source was used in order to evaluate to what extent such a light source is able to minimise cloud effects on prediction accuracies. A three years lasting experiment with maize was conducted in order to evaluate the potential of off-nadir measurements inside a canopy to predict different quality parameters in total biomass and DM yield using one sensor for a potential on-the-go application. This approach implements a measurement of the plants in 50 cm segments, since a sensor adjusted sideways is not able to record the entire plant height. Calibration results obtained by nadir top-of-canopy reflectance measurements were compared to calibration results obtained by off-nadir measurements. Results of all experiments approve the applicability of spectroscopic measurements for the prediction of distinct biophysical and biochemical parameters in the laboratory and under field conditions, respectively. The estimation of parameters could be conducted to a great extent with high accuracy. An enhanced basis of calibration for the laboratory study and the first field experiment (grass/clover-mixture) yields in improved robustness of calibration models and allows for an extended application of spectroscopic measurement techniques, even under varying conditions. Furthermore, off-nadir measurements inside a canopy yield in higher prediction accuracies, particularly for crops characterised by distinct height increment as observed for maize.
Resumo:
In der vorliegenden Arbeit wurden neue symmetrische Spiro-p-oligophenyle der allgemeinen Form Spiro-o-Φ[n,n] mit der Gesamtkettenlänge o=2n+2 Phenylringen (o > 10) und der Zahl n der Phenylringe in den p-Oligophenylsubstituenten am Spirobifluorenkern, dargestellt. Neben den symmetrischen Verbindungen wurden erstmals auch unsymmetrische Spiro-p-oligophenyle der allgemeinen Form Spiro-o-Φ[n,m] mit o=n+m+2 (o = 3-7) und n ≠ m synthetisiert. Aufgrund der sehr geringen Löslichkeit der größeren Verbindungen wurden löslichkeitssteigernde Substituenten an den endständigen Phenylringen angebracht. Bei den Verbindungen, die mit Trimethylsilyl-Gruppen (TMS-) in den endständigen meta-Positionen „3“ und „5“ substituiert wurden, konnte die Löslichkeit um mehrere Größenordnungen gesteigert werden, sodass die Darstellung der symmetrischen Verbindungen bis zu einer Kettenlänge von 16 Phenylringen möglich wurde. Nach erfolgreicher Synthese und Aufreinigung wurden die TMS-Gruppen wieder entfernt und die erhaltenen, unsubstituierten Verbindungen charakterisiert. Zusätzlich wurden auch die TMS-Derivate untersucht. Zur Charakterisierung zählten neben der Reinheits- und Strukturanalytik unter anderem auch spektroskopische (UV/Vis-Absorption, Fluoreszenz, Fluoreszenzquantenausbeute), elektrochemische (Cyclovoltammetrie) und thermische (Thermogravimetrie, Dynamische Differenzkalorimetrie) Untersuchungen. Hier wurde unter anderem der Einfluss der Kettenlänge und der Position der Spiroverknüpfung auf isomere Verbindungen gleicher Kettenlänge untersucht. Bei den spektroskopischen Messungen konnte eine Konvergenz der längstwelligen Absorptionsbanden, bzw. kürzestwelligen Fluoreszenzbanden mit zunehmender Kettenlänge beobachtet werden. Die effektive Konjugationslänge konnte so aus experimentellen Daten bestimmt werden zu 12 Phenylringen in der Absorption und 14 Phenylringen in der Fluoreszenz. Bei den Isomeren gleicher Kettenlänge zeigte sich in der Absorption eine hypsochrome Verschiebung der Absorptionsmaxima mit zunehmender Verschiebung der Spiroverknüpfung zum Kettenende hin, während die Position der Spiroverknüpfung keinen messbaren Einfluss auf die Verschiebung der Fluoreszenzbanden hatte. Die Substitution mit TMS in den meta-Positionen zeigte keinen messbaren Einfluss auf die Absorptions- bzw. Fluoreszenzbanden. Die elektrochemischen Untersuchungen zeigten mit zunehmender Kettenlänge eine erleichterte Oxidation und Reduktion, während bei Isomeren gleicher Kettenlänge die Oxidation mit Verschiebung der Spiroverknüpfung zum Kettenende hin erschwert und die Reduktion erleichtert war. Die thermogravimetrischen Analysen (TGA) zeigten eine außerordentlich hohe thermische Stabilität (5% Massenabnahme unter Schutzgas) der Spiro-p-oligophenyle von Td,5% = 474°C bei Spiro-5Φ[1,2] bis 570°C bei Spiro 8Φ[3,3]. Ebenso blieben hohe Rückstandsmassen unter Schutzgas bei 850°C zurück, wie das Beispiel Spiro 8Φ[3,3] mit 68% zeigt. Die Verbindungen zeigten hohe Schmelzpunkte (max. 496°C bei Spiro-6Φ[0,4]) und Glasübergangstemperaturen (max. 434°C bei p-TMS-Spiro-8Φ[3,3]). Viele der Verbindungen, besonders die in den meta-Positionen TMS-substituierten Verbindungen, bildeten stabile amorphe Gläser.
Resumo:
This thesis concerns with the main aspects of medical trace molecules detection by means of intracavity laser absorption spectroscopy (ICLAS), namely with the equirements for highly sensitive, highly selective, low price, and compact size sensor. A novel two modes semiconductor laser sensor is demonstrated. Its operation principle is based on the competition between these two modes. The sensor sensitivity is improved when the sample is placed inside the two modes laser cavity, and the competition between the two modes exists. The effects of the mode competition in ICLAS are discussed theoretically and experimentally. The sensor selectivity is enhanced using external cavity diode laser (ECDL) configuration, where the tuning range only depends on the external cavity configuration. In order to considerably reduce the sensor cost, relative intensity noise (RIN) is chosen for monitoring the intensity ratio of the two modes. RIN is found to be an excellent indicator for the two modes intensity ratio variations which strongly supports the sensor methodology. On the other hand, it has been found that, wavelength tuning has no effect on the RIN spectrum which is very beneficial for the proposed detection principle. In order to use the sensor for medical applications, the absorption line of an anesthetic sample, propofol, is measured. Propofol has been dissolved in various solvents. RIN has been chosen to monitor the sensor response. From the measured spectra, the sensor sensitivity enhancement factor is found to be of the order of 10^(3) times of the conventional laser spectroscopy.
Resumo:
In this thesis, a dual mode tunable gas sensor based on intracavity laser absorption spectroscopy (ICLAS) principle is investigated, both, numerically and experimentally. In order to minimize the cost and size of the gas sensor, relative intensity noise (RIN) is implemented as a detection parameter. Investigation is performed to determine the effect of injection current, operating temperature, mode spacing, and cavity length on RIN. It has been found that it is best to operate the gas sensor at smaller mode spacing and near the threshold current or at larger mode spacing and far above the threshold current for the use of RIN as the readout parameter.
Resumo:
To engineer complex synthetic biological systems will require modular design, assembly, and characterization strategies. The RNA polymerase arrival rate (PAR) is defined to be the rate that RNA polymerases arrive at a specified location on the DNA. Designing and characterizing biological modules in terms of RNA polymerase arrival rates provides for many advantages in the construction and modeling of biological systems. PARMESAN is an in vitro method for measuring polymerase arrival rates using pyrrolo-dC, a fluorescent DNA base that can substitute for cytosine. Pyrrolo-dC shows a detectable fluorescence difference when in single-stranded versus double-stranded DNA. During transcription, RNA polymerase separates the two strands of DNA, leading to a change in the fluorescence of pyrrolo-dC. By incorporating pyrrolo-dC at specific locations in the DNA, fluorescence changes can be taken as a direct measurement of the polymerase arrival rate.
Resumo:
We shall call an n × p data matrix fully-compositional if the rows sum to a constant, and sub-compositional if the variables are a subset of a fully-compositional data set1. Such data occur widely in archaeometry, where it is common to determine the chemical composition of ceramic, glass, metal or other artefacts using techniques such as neutron activation analysis (NAA), inductively coupled plasma spectroscopy (ICPS), X-ray fluorescence analysis (XRF) etc. Interest often centres on whether there are distinct chemical groups within the data and whether, for example, these can be associated with different origins or manufacturing technologies
Resumo:
IntraCavity Laser Absorption Spectroscopy (ICLAS) is a high-resolution, high sensitivity spectroscopic method capable of measuring line positions, linewidths, lineshapes, and absolute line intensities with a sensitivity that far exceeds that of a traditional multiple pass absorption cell or Fourier Transform spectrometer. From the fundamental knowledge obtained through these measurements, information about the underlying spectroscopy, dynamics, and kinetics of the species interrogated can be derived. The construction of an ICLA Spectrometer will be detailed, and the measurements utilizing ICLAS will be discussed, as well as the theory of operation and modifications of the experimental apparatus. Results include: i) Line intensities and collision-broadening coefficients of the A band of oxygen and previously unobserved, high J, rotational transitions of the A band, hot-band transitions, and transitions of isotopically substituted species. ii) High-resolution (0.013 cm-1) spectra of the second overtone of the OH stretch of trans-nitrous acid recorded between 10,230 and 10,350 cm-1. The spectra were analyzed to yield a complete set of rotational parameters and an absolute band intensity, and two groups of anharmonic perturbations were observed and analyzed. These findings are discussed in the context of the contribution of overtone-mediated processes to OH radical production in the lower atmosphere.
Resumo:
A series of InxAl1-xAs samples (0.51≪x≪0.55)coherently grown on InP was studied in order to measure the band-gap energy of the lattice matched composition. As the substrate is opaque to the relevant photon energies, a method is developed to calculate the optical absorption coefficient from the photoluminescence excitation spectra. The effect of strain on the band-gap energy has been taken into account. For x=0.532, at 14 K we have obtained Eg0=1549±6 meV
Resumo:
A thorough critical analysis of the theoretical relationships between the bond-angle dispersion in a-Si, Δθ, and the width of the transverse optical Raman peak, Γ, is presented. It is shown that the discrepancies between them are drastically reduced when unified definitions for Δθ and Γ are used. This reduced dispersion in the predicted values of Δθ together with the broad agreement with the scarce direct determinations of Δθ is then used to analyze the strain energy in partially relaxed pure a-Si. It is concluded that defect annihilation does not contribute appreciably to the reduction of the a-Si energy during structural relaxation. In contrast, it can account for half of the crystallization energy, which can be as low as 7 kJ/mol in defect-free a-Si
Resumo:
Metal pollution in rivers is in great concern with human activities in the fluvial watershed. This thesis aims to investigate the potential use of chl-a fluorescence parameters as biomarkers of metal toxicity, and to find cause-effect relationships between metal exposures, other environmental factor (i.e. light), and functional and structural biofilm responses. This thesis demonstrates that the use of chl-a fluorescence parameters allows detect early effects on biofilms caused by zinc toxicity, both in the laboratory as in polluted rivers. In microcosm experiments, the use of chl-a fluorescence parameters allows evaluates structural changes on photosynthetic apparatus and in algal groups’ composition of biofilms long-term exposed to zinc. In order to evaluate the effects of chronic metal pollution in rivers, it is recommended the use of biofilm translocation experiments and the use of a multi-biomarker approach.