967 resultados para FIXED-DOSE COMBINATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: Bone-seeking radionuclides including samarium-153 ethylene diamine tetramethylene phosphonate and strontium-89 have been used for decades in the palliation of pain from bone metastases especially from prostate cancer. Emerging evidence of improved survival in metastatic castration-resistant prostate cancer (CRPC) with the first-in-class a-radionuclide, radium-223 (Ra) has rekindled interest in the role of bone-seeking radionuclide therapy.We review the literature for randomized controlled trials of bone-seeking radionuclides and explore some of the issues regarding the optimal use of these agents. In particular, we discuss dose, dose rate, radiobiology, and quality of radiation and postulate on potential future directions in particular combination schedules. ß-Emitting, bone-seeking radionuclides have proven ability to control pain in prostate cancer metastatic to bone with pain response rates in the order of 60% to 70% when used as single agents. Most of the published trials were underpowered to detect differences in survival; however, there is evidence of the potential for disease modification when these agents are used in combination with chemotherapy or in multiple cycles.Data from the recent phase III ALSYMPCA trial that compared Ra to placebo in symptomatic CRPC demonstrate a significant improvement in median overall survival of 3.6 months for patients with symptomatic CRPC metastatic to bone treated with 6 cycles of the a-emitting radionuclide Ra compared with placebo. The success of Ra in improving survival in CRPC will lead this agent to become part of the treatment paradigm for this disease, and with such an excellent safety profile, Ra has huge potential in combination strategies as well as for use earlier in the natural history of metastatic prostate cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our intent was to investigate the neurodevelopment of HIV-uninfected children exposed to combination highly active antiretroviral therapy in pregnancy compared with children not exposed to highly active antiretroviral therapy but with similar socioeconomic backgrounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cancer is a complex and heterogeneous disease which is one of the leading causes of death in Western civilisations. Thus, oncology is viewed as a primary focus for personalized medicine. It is recognised that cancer treatment needs to be better tailored in order to improve patient outcome. Patient tumor samples will be required to characterize cancer at a molecular level and identify where there may be disease subgroups that should be treated differently. The use of formalin-fixed paraffin-embedded tissue is important for enabling such studies. In this report, we focus on the challenges that have been faced to date along with the technological developments that have now made this possible. We also highlight the impact this may have on drug and diagnostic development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Fluticasone propionate was introduced in 1993 in the UK as a potentially safer inhaled corticosteroid than those already in use. The efficacy and safety of fluticasone has been established at recommended doses of 200 µg/day, but not at the higher doses that are often used.

Methods: Growth retardation was observed in six severely asthmatic children after introduction of high-dose fluticasone propionate treatment (dry powder). Assessment of cortisol response was by insulin-induced hypoglycaemia in three cases, by short tetracosactrin test in two, and by low-dose tetracosactrin and 24-hour urinary cortisol/creatinine ratio in one.

Findings: Six children with growth retardation noted after treatment with high-dose fluticasone propionate were found to have adrenal suppression. In one case the growth rate and cortisol response returned to normal 9 months after the fluticasone dose was reduced to 500 µg/day.

Interpretation: When high doses of fluticasone propionate are used, growth may be retarded and adrenal suppression may occur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method to spatially probe heterogeneous catalysed reactions within a packed bed of catalyst has been developed. The spatial resolution is achieved using a stationary perforated capillary coupled to a mass spectrometer while the catalyst bed is moved. The oxidation of CO promoted by H-2 over a Pd catalyst has been used to demonstrate the technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.