967 resultados para Detectors òptics
Resumo:
Thermal Diagnostics experiments to be carried out on board LISA Pathfinder (LPF) will yield a detailed characterisation of how temperature fluctuations affect the LTP (LISA Technology Package) instrument performance, a crucial information for future space based gravitational wave detectors as the proposed eLISA. Amongst them, the study of temperature gradient fluctuations around the test masses of the Inertial Sensors will provide as well information regarding the contribution of the Brownian noise, which is expected to limit the LTP sensitivity at frequencies close to 1mHz during some LTP experiments. In this paper we report on how these kind of Thermal Diagnostics experiments were simulated in the last LPF Simulation Campaign (November, 2013) involving all the LPF Data Analysis team and using an end-to-end simulator of the whole spacecraft. Such simulation campaign was conducted under the framework of the preparation for LPF operations.
Resumo:
A ocratoxina A e a citrinina são micotoxinas encontrados naturalmente em alimentos e rações animais. A avaliação do risco do consumo de alimentos contaminados por esses compostos deve ser estimada a partir de dados confiáveis que reflitam a verdadeira concentração destas toxinas em diferentes alimentos ou insumos, especialmente se ingeridos com freqüência. Isto gera a necessidade de métodos analíticos precisos que sejam rápidos sem desconsiderar as etapas clássicas de avaliação de traços, amostragem representativa, extração, limpeza, concentração, separação de formas químicas, detecção, confirmação de identidade e quantificação. Para as micotoxinas em geral as técnicas cromatográficas são as mais aplicadas e relatadas em vista da diversidade estrutural destes compostos. Neste trabalho foi realizada uma otimização de extração utilizando o método QuEChERS modificado em comparação com os métodos Soares e Rodrigues Amaya (1989), Tanaka (2001) e Ultrassom (Palma et. al., 2007) empregando diferentes técnicas cromatográficas com detectores distintos para análise destas micotoxinas simultaneamente. Foram analisadas 38 amostras de arroz cultivadas e armazenadas em campos experimentais de Cachoeirinha na região Sul do Brasil. O uso dos sistemas CCD, HPLC-DAD e LC-MS proporcionou especificidade, precisão e sensibilidade, de modo que os limites de detecção e quantificação, obtivessem valores inferiores ao limite máximo estabelecido por órgãos reguladores internacionais (5 µg Kg-1 para ocratoxina A). Os limites de detecção encontrados para citrinina e ocratoxina A em camada delgada foram 4,7 e 6 vezes maior que para cromatografia líquida de alta eficiência acoplada a detector de arranjo de diodos, 14 e 300 vezes maior que cromatografia líquida acoplada a detector de massas. Os limites de quantificação das duas micotoxinas ficaram dentro do exigido pela legislação européia para OTA de 5 µg Kg-1 para HPLC-DAD e LC-MS. Na cromatografia de camada delgada esse valor ficou 4 vezes acima do estabelecido para ocratoxina A. A ocorrência de ocratoxina A e citrinina foi verificada em 16 % das amostras estando os teores variando entre 3 e 560 µg Kg-1, sugerindo possível exposição crônica a estas micotoxinas caso as amostras sejam consumidas.
Resumo:
The Solar Intensity X-ray and particle Spectrometer (SIXS) on board BepiColombo's Mercury Planetary Orbiter (MPO) will study solar energetic particles moving towards Mercury and solar X-rays on the dayside of Mercury. The SIXS instrument consists of two detector sub-systems; X-ray detector SIXS-X and particle detector SIXS-P. The SIXS-P subdetector will detect solar energetic electrons and protons in a broad energy range using a particle telescope approach with five outer Si detectors around a central CsI(Tl) scintillator. The measurements made by the SIXS instrument are necessary for other instruments on board the spacecraft. SIXS data will be used to study the Solar X-ray corona, solar flares, solar energetic particles, the Hermean magnetosphere, and solar eruptions. The SIXS-P detector was calibrated by comparing experimental measurement data from the instrument with Geant4 simulation data. Calibration curves were produced for the different side detectors and the core scintillator for electrons and protons, respectively. The side detector energy response was found to be linear for both electrons and protons. The core scintillator energy response to protons was found to be non-linear. The core scintillator calibration for electrons was omitted due to insufficient experimental data. The electron and proton acceptance of the SIXS-P detector was determined with Geant4 simulations. Electron and proton energy channels are clean in the main energy range of the instrument. At higher energies, protons and electrons produce non-ideal response in the energy channels. Due to the limited bandwidth of the spacecraft's telemetry, the particle measurements made by SIXS-P have to be pre-processed in the data processing unit of the SIXS instrument. A lookup table was created for the pre-processing of data with Geant4 simulations, and the ability of the lookup table to provide spectral information from a simulated electron event was analysed. The lookup table produces clean electron and proton channels and is able to separate protons and electrons. Based on a simulated solar energetic electron event, the incident electron spectrum cannot be determined from channel particle counts with a standard analysis method.