997 resultados para Alpha-spectrometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correction of spectral overlap interference in inductively coupled plasma atomic emission spectrometry by factor analysis is attempted. For the spectral overlap of two known lines, a data matrix can be composed from one or two pure spectra and a spectrum of the mixture. The data matrix is decomposed into a spectra matrix and a concentration matrix by target transformation factor analysis. The component concentration of interest in a binary mixture is obtained from the concentration matrix and interference from the other component is eliminated. This method is applied to correcting spectral interference of yttrium on the determination of copper and aluminium: satisfactory results are obtained. This method may also be applied to correcting spectral overlap interference for more than two lines. Like other methods of correcting spectral interferences, factor analysis can only be used for additive spectral overlap. Results obtained from measurements on copper/yttrium mixtures with different white noise added show that random errors in measurement data do not significantly affect the results of the correction method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unsteady diffusion kinetic, recently advanced by this laboratory, is applied to the examination of some polymerization and molecular chain structure problems. Hitherto deemed "anomalous" phenomena, such as the faster rate of copolymerization of ethylene/alpha-olefin than the homopolymerization of ethylene and the enrichment in the incorporation of a higher alpha-olefin in its copolymerization with ethylene by a lower alpha-olefin, are reasonably explained by unsteady diffusion of monomers. Molecular chain structure of copolymers, such as compositional heterogeneity and its dependence on comonomer incorporation originates from the difference in diffusion coefficients of the monomers. A copolymer composition equation taking into consideration the unsteady diffusion was developed. In cases where simulated curves were compared with experimental curves, good agreements were found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Kalman filter was developed for resolving overlapping lines in inductively coupled plasma atomic emission spectrometry (ICP-AES) and evaluated experimentally with the determination of La in the presence of Ho, and Cu in the presence of Pr. The whiteness of the innovation sequence for an optimal filter was explored to be the criterion for the correction of the wavelength positioning errors which may occur in spectral scans. Under the conditions of the medium-resolution spectrometer and 1.5 pm step size in scans, the filter effectively resolved the Cu/Pr line pair having a small peak separation of 4.8 pm. For the La/Ho line pair with a peak distance of 9.8 pm, an unbiased estimate for La concentration was still obtained even when the signal-to-background ratio was down to 0.048. Favourable detection limits for real samples were achieved. Unstructured backgrounds were modeled theoretically and all spectral scans therefore did not require the correction for solvent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unimolecular Charge separation reactions of the doubly charged ions [C6H4Cl2]2+, [C6H3Cl]2+ produced in the ion source by electron impact from o-, m-, and p-dichloro benzene have been studied using mass analysed ion kinetic energy spectrometry. The values of kinetic energy releases (T) can be calculated from the energy dispersion of product ions. As T essentially reflects the release of coulombic energy, which can be used to calculate the approximate distances R between the two charges immediately before decomposition of the ions. From these data, some structural information about transiton states could be provided. The ECID and CID processes of above doubly charged ions, have also been studied. We found that the CID reactions of (C6H4Cl2)2+ could be used to distinguish three dichloro benzene isomers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the evaluation of the reliability of the analytical results obtained by Kalman filtering. Two criteria for evaluation were compared: one is based on the autocorrelation analysis of the innovation sequence, the so-called NAC criterion; the other is the innovations number, which actually is the autocorrelation coefficient of the innovation sequence at the initial wavelength. Both criteria allow compensation for the wavelength positioning errors in spectral scans, but there exists a difference in the way they work. The NAC criterion can provide information about the reliability of an individual result, which is very useful for the indication of unmodelled emissions, while the innovations number should be incorporated with the normalization of the innovations or seek the help of the sequence itself for the same purpose. The major limitation of the NAC criterion is that it does not allow the theoretical modelling of continuous backgrounds, which, however, is convenient in practical analysis and can be taken with the innovations number criterion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unimolecular charge separation reactions of the doubly charged ions FeC10H102+, FeC10H theta 2+, FeC10H82+ produced in the ion source by electron impact from ferrocene have been studied using Mass analyzed Ion Kinetic Energy Spectrometry (MIKES) technique. From the values of the kinetic energy releases (T), the intercharge distances (R) of the exploding doubly charged ions in their transition structures have been estimated and some structural informations about the transition states can be obtained. The collision induced reactions of the FeC10H102+ ion with Ar have been studied using MIKES, we postulate a new type of continuing reaction which may be "collisional charge separation induced dissociation".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bis(methylcyclopentadienyl)chloro(alpha-naphthoyloxy)zirconium, (CH3C5H4)2Zr Cl(alpha-C10H7COO), has been synthesized by the reaction between (MeCp)2ZrCl2 and equimolar sodium alpha-naphthoate in toluene at room temperature. The molecular structure of the title complex was determined by X-ray diffraction. The molecules have a five-coordinate bent metallocene structure in which the alpha-naphthoxyligand is bidentate [Zr-O, 2.317(2), 2.260(2) angstrom]. The remaining distances are [Zr-Cl, 2.521(1) angstrom; Zr-C, 480-2, 565 angstrom; Zr-cent-CH3C5H4 2.217 and 2.230 angstrom].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most attractive features of derivative spectrometry is its higher resolving power. In the present power, numerical derivative techniques are evaluated from the viewpoint of increase in selectivity, the latter being expressed in terms of the interferent equivalent concentration (IEC). Typical spectral interferences are covered, including flat background, sloped background, simple curved background and various types of line overlap with different overlapping degrees, which were defined as the ratio of the net interfering signal at the analysis wavelength to the peak signal of the interfering line. the IECs in the derivative spectra are decreased by one to two order of magnitudes compared to those in the original spectra, and in the most cases, assume values below the conventional detection limits. The overlapping degree is the dominant factor that determines whether an analysis line can be resolved from an interfering line with the derivative techniques. Generally, the second derivative technique is effective only for line overlap with an overlapping degree of less than 0.8. The effects of other factors such as line shape, data smoothing, step size and the intensity ratio of analyte to interferent on the performance of the derivative techniques are also discussed. All results are illustrated with practical examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between the alpha-N index and physical properties of neutral phosphorus extractants is studied. Using the general alpha-N index which could describe extractants with minute difference in structure, the good correlation between it and various physical properties of the neutral phosphorus extractants (e.g., densities, refractive index, shift ratio of paper chromatography and IR frequencies of bond P = O) is obtained. The result indicates that general alpha-N index is a good topological index of organic compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dispersion of alumina particles on a glassy-carbon surface serving as a modified electrode significantly enhances the amperometric detection of cysteine and glutathione following liquid chromatography. With an applied potential of 0.8 V vs. SCE, the detection limits were 1.2 ng for cysteine and 8 ng for glutathione and the electrode response was linear up to 600 ng for cysteine and 1.8-mu-g for glutathione. The modified electrode displayed high sensitivity and stability and was easy and inexpensive to prepare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the results of the crystal and molecular structures, CI-MS and FAB-MS analyse of Cl3GeCH2CH2COOH and Cl3GeCH(CH3)CH2COOH. The characters and active parts of these molecules are also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The general a(N) index is established for molecules containing heteroatoms, rings, and multiple bonds. The general a(N) index is able to describe molecules with minute differences in structure and can also reveal the properties of molecules. This theory is successfully applied to the case of neutral phosphorus extractants. Both the molecular polarity and steric effect are characterized by the general a(N) index. The relationships between these properties and the distribution ratios for extracting Y, Ce, U, and Th are also shown by the general a(N) index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To express and product a fluorescent antioxidant holo-alpha-phycocyanin (PC) of Spirulina platensis (Sp) with His-tag (rHHPC; recombinant holo-alpha-phycocyaninof Spirulina platensis with His-tag) in 5-l bench scale. A vector harbouring two cassettes was constructed: cpcA along with cpcE-cpcF in one cassette; ho1-pcyA in the other cassette. Lyases CpcE/F of Synechocystis sp. PCC6803 (S6) could catalyse the 82 site Cys in apo-alpha-PC of Sp linking with bilin chromophores, and rHHPC was biosynthesized in Escherichia coli BL21. The constant feeding mode was adopted, and transformant reached the biomass of rHHPC up to 0.55 g l(-1) broth in 5-litre bench scale. rHHPC was purified by Ni2+ affinity column conveniently. The absorbance and the fluorescence emission spectra of rHHPC had lambda(max) at 621 and 650 nm, respectively. The IC50 values of rHHPC were 277.5 +/- 25.8 mu g ml(-1) against hydroxyl radicals and 20.8 +/- 2.2 mu g ml(-1) against peroxyl radicals. Combinational biosynthesis of rHHPC was feasible, and the constant feeding mode was adopted to produce good yields of rHHPC. Fluorescent rHHPC with several unique qualitative and quantitative features was effective on scavenging hydroxyl and peroxyl radicals. A potent antioxidant rHHPC was co-expressed, produced and characterized for nutritional and pharmacological values, which would help to develop phycobiliproteins' applications in their fluorescent and biological activities.