983 resultados para 165-1001


Relevância:

10.00% 10.00%

Publicador:

Resumo:

针对非合作小目标激光测距系统,目标表面的反射特征对激光回波信号有很大的影响。建立测量表面双向反射分布函数(BRDF)的装置,对常用的两种热控材料——白漆涂层和F36多包层,测量了其在1064 nm波长下的双向反射分布函数。得出了白漆涂层镜面反射很小,散射角较大,利于各方向接收回波信号;而F36多包层镜面反射很强,散射角-2°~2°,不利于探测。通过由表面BRDF与由朗伯散射计算得到的最小接收功率的比较,得出了入射角大于45°入射白漆涂层时,回波信号较小;大于2°入射F36多包层时,没有回波信号。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

采用光纤缠绕的方法,来抑制大模场面积(LMA)双包层光纤激光器中的高阶模振荡。将光纤缠绕至两种不同半径,实验测量了相应条件下激光器的输出功率和光束质量因子M2。缠绕半径为165mm时,输出功率为217W,M2为2.96;缠绕半径为52mm时,输出功率为160W,M2为1.38。光纤激光器相应的斜率效率分别为60%和48%。光纤缠绕半径较小时,虽然激光器输出功率减小,但其亮度是大缠绕半径时对应值的3.4倍。

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN]Hyperventilation, which is common both in-hospital and out-of-hospital cardiac arrest, decreases coronary and cerebral perfusion contributing to poorer survival rates in both animals and humans. Current resucitation guidelines recommend continuous monitoring of exhaled carbon dioxide (CO2) during cardiopulmonary resucitation (CPR) and emphasize good quality of CPR, including ventilations at 8-10 min1. Most of commercial monitors/de- brilators incorporate methods to compute the respiratory rate based on capnography since it shows uctuations caused by ventilations. Chest compressions may induce artifacts in this signal making the calculation of the respiratory rate di cult. Nevertheless, the accuracy of these methods during CPR has not been documented yet. The aim of this project is to analyze whether the capnogram is reliable to compute ventilation rate during CPR. A total of 91 episodes, 63 out-of-hospital cardiac arrest episodes ( rst database) and 28 in-hospital cardiac arrest episodes (second database) were used to develop an algorithm to detect ventilations in the capnogram, and the nal aim is to provide an accurate ventilation rate for feedback purposes during CPR. Two graphic user interfaces were developed to make the analysis easier and another two were adapted to carry out this project. The use of this interfaces facilitates the managment of the databases and the calculation of the algorithm accuracy. In the rst database, as gold standard every ventilation was marked by visual inspection of both the impedance, which shows uctuations with every ventilation, and the capnography signal. In the second database, volume of the respiratory ow signal was used as gold standard to mark ventilation instants since it is not a ected by chest compressions. The capnogram was preprocessed to remove high frequency noise, and the rst di erence was computed to de ne the onset of inspiration and expiration. Then, morphological features were extracted and a decission algorithm built based on the extracted features to detect ventilation instants. Finally, ventilation rate was calculated using the detected instants of ventilation. According to the results obtained in this project, the capnogram can be reliably used to give feedback ventilation rate, and therefore, on hyperventilation in a resucitation scenario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on cooperative downconversion in Yb3+-RE3+ (RE = Tm or Pr) codoped lanthanum borogermanate glasses (LBG), which are capable of splitting a visible photon absorbed by Tm3+ or Pr3+ ions into two near-infrared photons. The results indicate that Pr3+-Yb3+ is a more efficient ion couple than Tm3+-Yb3+ in terms of cooperative downconversion. We have obtained a highest quantum yield of 165% and 138% for Pr3+-Yb3+ and Tm3+-Yb3+ codoped LBG glasses under 468 nm excitation, respectively. However, ultraviolet light excitation to the charge transfer band of Yb3+ does not result in quantum splitting as rapid relaxation from the charge transfer band to 4f(13) levels of Yb3+ dominates. (C) 2008 Optical Society of America