947 resultados para vector tiles


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for quantitative mineralogical analysis by ATR-FTIR has been developed. The method relies on the use of the main band of calcite as a reference for the normalization of the IR spectrum of a mineral sample. In this way, the molar absorptivity coefficient in the Lambert–Beer law and the components of a mixture in mole percentage can be calculated. The GAMS equation modeling environment and the NLP solver CONOPT (©ARKI Consulting and Development) were used to correlate the experimental data in the samples considered. Mixtures of different minerals and gypsum were used in order to measure the minimum band intensity that must be considered for calculations and the detection limit. Accordingly, bands of intensity lower than 0.01 were discarded. The detection limit for gypsum was about 7% (mol/total mole). Good agreement was obtained when this FTIR method was applied to ceramic tiles previously analyzed by X-ray diffraction (XRD) or mineral mixtures prepared in the lab.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas. Methods. This study comprised a total of 43 keratoconic eyes (27 patients, 17–73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11–54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15–64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system. Anterior corneal topographic data was imported from it to the iASSORT software (ASSORT Pty. Ltd), which allowed the calculation of ORA and TD. Results. Mean magnitude of the ORA was 3.23 ± 2.38, 1.16 ± 0.50 and 0.79 ± 0.43 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Mean magnitude of the TD was 9.04 ± 8.08, 2.69 ± 2.42 and 0.89 ± 0.50 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Good diagnostic performance of ORA (cutoff point: 1.21 D, sensitivity 83.7 %, specificity 87.1 %) and TD (cutoff point: 1.64 D, sensitivity 93.3 %, specificity 92.1 %) was found for the detection of keratoconus. The diagnostic ability of these parameters for the detection of subclinical keratoconus was more limited (ORA: cutoff 1.17 D, sensitivity 60.0 %, specificity 84.2 %; TD: cutoff 1.29 D, sensitivity 80.0 %, specificity 80.2 %). Conclusion. The vector parameters ORA and TD are able to discriminate with good levels of precision between keratoconus and healthy corneas. For the detection of subclinical keratoconus, only TD seems to be valid.