963 resultados para two-layer fluid


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two-phase flow of a hydrophobic ionic liquid and water was studied in capillaries made of three different materials (two types of Teflon, FEP and Tefzel, and glass) with sizes between 200µm and 270µm. The ionic liquid was 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide, with density and viscosity of 1420kgm and 0.041kgms, respectively. Flow patterns and pressure drop were measured for two inlet configurations (T- and Y-junction), for total flow rates of 0.065-214.9cmh and ionic liquid volume fractions from 0.05 to 0.8. The continuous phase in the glass capillary depended on the fluid that initially filled the channel. When water was introduced first, it became the continuous phase with the ionic liquid forming plugs or a mixture of plugs and drops within it. In the Teflon microchannels, the order that fluids were introduced did not affect the results and the ionic liquid was always the continuous phase. The main patterns observed were annular, plug, and drop flow. Pressure drop in the Teflon microchannels at a constant ionic liquid flow rate, was found to increase as the ionic liquid volume fraction decreased, and was always higher than the single phase ionic liquid value at the same flow rate as in the two-phase mixture. However, in the glass microchannel during plug flow with water as the continuous phase, pressure drop for a constant ionic liquid flow rate was always lower than the single phase ionic liquid value. A modified plug flow pressure drop model using a correlation for film thickness derived for the current fluids pair showed very good agreement with the experimental data. © 2013 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In vitro assays are invaluable for the biochemical characterization of UDP-sugar:undecaprenyl-phosphate sugar-1-phosphate transferases. These assays typically involve the use of a radiolabeled substrate and subsequent extraction of the product, which resides in a lipid environment. Here, we describe the preparation of bacterial membranes containing these enzymes, a standard in vitro transferase assay with solvents containing chloroform and methanol, and two methods to measure product formation: scintillation counting and thin layer chromatography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work reports a comparative study on the performances of two bis[(trifluoromethyl)sulfonyl]imide-based protic (PIL) and aprotic (AIL) ionic liquids, namely, trimethyl-ammonium bis[(trifluoromethyl)sulfonyl]imide ([HN][TFSI], PIL) and trimethyl-sulfonium bis[(trifluoromethyl) sulfonyl]imide ([S][TFSI], AIL), as mixtures with three molecular solvents: gamma butyrolactone (?-BL), propylene carbonate (PC), and acetonitrile (ACN) as electrolytes for supercapacitor applications. After an analysis of their transport properties as a function of temperature, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and galvanostatic charge-discharge measurements were conducted at 25 and -30 C to investigate the performance of these mixtures as electrolytes for supercapacitors using activated carbon as the electrode material. Surprisingly, for each solvent investigated, no significant differences were observed between the electrolytes based on the PIL and AIL in their electrochemical performance due to the presence or the absence of the labile proton. Furthermore, good specific capacitances were observed in the case of ?-BL-based electrolytes even at low temperature. Capacitances up to 131 and 80 F·g are observed for the case of the [S][TFSI] + ?-BL mixture at 25 and -30 C, respectively. This latter result is very promising particularly for the formulation of new environmentally friendly electrolytes within energy storage systems even at low temperatures. © 2013 American Chemical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many of the physiological functions of von Willebrand Factor (VWF), including its binding interaction with blood platelets, are regulated by the magnitude of applied fluid/hydrodynamic stress. We applied two complementary strategies to study the effect of fluid forces on the solution structure of VWF. First, small-angle neutron scattering was used to measure protein conformation changes in response to laminar shear rates (G) up to 3000/s. Here, purified VWF was sheared in a quartz Couette cell and protein conformation was measured in real time over length scales from 2-140 nm. Second, changes in VWF structure up to 9600/s were quantified by measuring the binding of a fluorescent probe 1,1'-bis(anilino)-4-,4'-bis(naphtalene)-8,8'-disulfonate (bis-ANS) to hydrophobic pockets exposed in the sheared protein. Small angle neutron scattering studies, coupled with quantitative modeling, showed that VWF undergoes structural changes at G < 3000/s. These changes were most prominent at length scales <10 nm (scattering vector (q) range >0.6/nm). A mathematical model attributes these changes to the rearrangement of domain level features within the globular section of the protein. Studies with bis-ANS demonstrated marked increase in bis-ANS binding at G > 2300/s. Together, the data suggest that local rearrangements at the domain level may precede changes at larger-length scales that accompany exposure of protein hydrophobic pockets. Changes in VWF conformation reported here likely regulate protein function in response to fluid shear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we investigate the physical layer secrecy performance of a single-input single-output system that consists of single antenna devices and operates in the presence of a single antenna passive eavesdropper over dissimilar fading channels. In particular, we consider two scenarios in terms of dissimilar fading channel arrangements: the legal/illegal channels are subject to Rayleigh/Rician fading, respectively; and the legal/illegal channels are subject to Rician/Rayleigh fading, respectively. Specifically, analytical expressions for the probability of the existence of a non-zero secrecy capacity and the secrecy outage probability are derived by using statistical characteristics of the signal-to-noise ratio. Numerical results are provided for selected scenarios to illustrate applications of the developed analytical expressions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In an effort to develop a novel electronic paper image display technology based on the electrowetting principle, a 3-D electrowetting cell is designed and fabricated, which consists of two 3-D bent electrodes, each having a horizontal surface made of gold and a vertical surface made of indium tin oxide (ITO) glass as a color display window, a layer of dielectric material on the 3-D electrodes, and a highly fluorinated hydrophobic layer on the surface of the dielectric layer. Results of this work show that an electrowetting-induced motion of an aqueous droplet in immiscible oils can be achieved reversibly across the boundary of the horizontal and vertical surfaces of the 3-D electrode surface. It is also shown that the droplet can maintain its wetting state on a vertical sidewall electrode free of a power supplier when the voltage is removed. This phenomenon may form the basis for color contrast modulation applications, where a power-free image display is required, such as electronic paper display technology in the future. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3100201]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel diffusive gradients in thin film probe developed comprises diffusive gel layer of silver iodide (AgI) and a back-up Microchelex resin gel layer. 2D high-resolution images of sulfide and trace metals were determined respectively on the AgI gel by densitometric analysis and on the Microchelex resin layer with laser-ablation-inductively-coupled plasma mass spectrometry (LA-ICP-MS).We investigated the validity of the analytical procedures used for the determination of sulfide and trace metals. We found low relative standard deviations on replicate measurements, linear trace-metal calibration curves between the LA-ICP-MS signal and the true trace-metal concentration in the resin gel, and a good agreement of the sulfide results obtained with the AgI resin gel and with other analytical methods. The method was applied on anoxic sediment pore waters in an estuarine and marine system. Simultaneous remobilization of sulfide and trace metals was observed in the marine sediment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Herein, we present the formulation and the characterization of novel adiponitrile-based electrolytes as a function of the salt structure, concentration, and temperature for supercapacitor applications using activated carbon based electrode material. To drive this study two salts were selected, namely, the tetraethylammonium tetrafluoroborate and the 1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide. Prior to determination of their electrochemical performance, formulated electrolytes were first characterized to quantify their thermal, volumetric, and transport properties as a function of temperature and composition. Then, cyclic voltammetry and electrochemical impedance spectroscopy techniques were used to investigate their electrochemical properties as electrolyte for supercapacitor applications in comparison with those reported for the currently used model electrolyte based on the dissolution of 1 mol·dm–3 of tetraethylammonium tetrafluoroborate in acetonitrile. Surprisingly, excellent electrochemical performances were observed by testing adiponitrile-based electrolytes, especially those containing the 1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide room-temperature molten salt. Differences observed on electrochemical performances between the selected adiponitrile electrolytes based on high-temperature (tetraethylammonium tetrafluoroborate) and the room-temperature (1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide) molten salts are mainly driven by the salt solubility in adiponitrile, as well as by the charge and the structure of each involved species. Furthermore, in comparison with classical electrolytes, the selected adiponitrile +1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide solution exhibits almost similar specific capacitances and lower equivalent serial resistance. These results demonstrate in fact that the adiponitrile +1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide mixture can be used for the formulation of safer electrolytes presenting a very low vapor pressure even at high temperatures to design acetonitrile-free supercapacitor devices with comparable performances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: In this cohort study, we explored the relationship between fluid balance, intradialytic hypotension and outcomes in critically ill patients with acute kidney injury (AKI) who received renal replacement therapy (RRT).

Methods: We analysed prospectively collected registry data on patients older than 16 years who received RRT for at least two days in an intensive care unit at two university-affiliated hospitals. We used multivariable logistic regression to determine the relationship between mean daily fluid balance and intradialytic hypotension, both over seven days following RRT initiation, and the outcomes of hospital mortality and RRT dependence in survivors.

Results: In total, 492 patients were included (299 male (60.8%), mean (standard deviation (SD)) age 62.9 (16.3) years); 251 (51.0%) died in hospital. Independent risk factors for mortality were mean daily fluid balance (odds ratio (OR) 1.36 per 1000 mL positive (95% confidence interval (CI) 1.18 to 1.57), intradialytic hypotension (OR 1.14 per 10% increase in days with intradialytic hypotension (95% CI 1.06 to 1.23)), age (OR 1.15 per five-year increase (95% CI 1.07 to 1.25)), maximum sequential organ failure assessment score on days 1 to 7 (OR 1.21 (95% CI 1.13 to 1.29)), and Charlson comorbidity index (OR 1.28 (95% CI 1.14 to 1.44)); higher baseline creatinine (OR 0.98 per 10 mu mol/L (95% CI 0.97 to 0.996)) was associated with lower risk of death. Of 241 hospital survivors, 61 (25.3%) were RRT dependent at discharge. The only independent risk factor for RRT dependence was pre-existing heart failure (OR 3.13 (95% CI 1.46 to 6.74)). Neither mean daily fluid balance nor intradialytic hypotension was associated with RRT dependence in survivors. Associations between these exposures and mortality were similar in sensitivity analyses accounting for immortal time bias and dichotomising mean daily fluid balance as positive or negative. In the subgroup of patients with data on pre-RRT fluid balance, fluid overload at RRT initiation did not modify the association of mean daily fluid balance with mortality.

Conclusions: In this cohort of patients with AKI requiring RRT, a more positive mean daily fluid balance and intradialytic hypotension were associated with hospital mortality but not with RRT dependence at hospital discharge in survivors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent analyses of sediment samples from "black mat" sites in South America and Europe support previous interpretations of an ET impact event that reversed the Late Glacial demise of LGM ice during the Bølling Allerød warming, resulting in a resurgence of ice termed the Younger Dryas (YD) cooling episode. The breakup or impact of a cosmic vehicle at the YD boundary coincides with the onset of a 1-kyr long interval of glacial resurgence, one of the most studied events of the Late Pleistocene. New analytical databases reveal a corpus of data indicating that the cosmic impact was a real event, most possibly a cosmic airburst from Earth's encounter with the Taurid Complex comet or unknown asteroid, an event that led to cosmic fragments exploding interhemispherically over widely dispersed areas, including the northern Andes of Venezuela and the Alps on the Italian/French frontier. While the databases in the two areas differ somewhat, the overall interpretation is that microtextural evidence in weathering rinds and in sands of associated paleosols and glaciofluvial deposits carry undeniable attributes of melted glassy carbon and Fe spherules, planar deformation features, shock-melted and contorted quartz, occasional transition and platinum metals, and brecciated and impacted minerals of diverse lithologies. In concert with other black mat localities in the Western USA, the Netherlands, coastal France, Syria, Central Asia, Peru, Argentina and Mexico, it appears that a widespread cosmic impact by an asteroid or comet is responsible for deposition of the black mat at the onset of the YD glacial event. Whether or not the impact caused a 1-kyr interval of glacial climate depends upon whether or not the Earth had multiple centuries-long episodic encounters with the Taurid Complex or asteroid remnants; impact-related changes in microclimates sustained climatic forcing sufficient to maintain positive mass balances in the reformed ice; and/or inertia in the Atlantic thermohaline circulation system persisted for 1kyr. 

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: LL-37, an anti-microbial peptide belonging to the cathelicidin family, derives its name from two N-terminal leucine residues and the 37 amino acids comprising the peptide. LL-37 is the only known cathelicidin to exist in humans. It exhibits both anti-bacterial and immunomodulatory properties. Objectives: In the current study, LL-37 was quantified in GCF from periodontitis patients. Previous studies have relied on qualitative results from Western blotting to detect LL-37 in GCF. This study aims to quantitatively determine LL-37 levels in GCF. Methods: GCF and bacterial plaque samples, pre- and post non-surgical periodontal treatment, were collected from 4 sites in 12 patients presenting with advanced periodontitis. Plaque samples were analysed by QPCR for the presence or absence of the periodontopathic bacterium Porphyromonas gingivalis (P. gingivalis). The concentrations of LL-37 in patient samples pre- and post-treatment were deduced by indirect enzyme linked immunosorbent assay (ELISA). Results: Concentrations of LL-37 in samples varied between a minimum and maximum of 1 and 40 ng/ml. LL-37 levels were shown, pre-treatment, to be higher in deep pockets (6-9 mm) compared with shallower pockets (3-5 mm) and highest in those sites which were positive for P. gingivalis. Non-surgical therapy resulted in a significant improvement in clinical indices while expression levels of P. gingivalis were reduced. Following treatment, LL-37 levels in GCF decreased from an average of 6.5 ± 1 - 5.8 ± 1.2 ng/ml. The most interesting observation however was the reduction in LL-37 levels, from an average of 7 ± 1.3 – 2.5 ± 1.1 ng/ml in those sites where P. gingivalis infection was eradicated post-treatment. Conclusions: LL-37 levels are increased at sites showing advanced periodontal disease, reduce following treatment and appear to be linked to the presence of P. gingivalis. This study will further our knowledge of host defence in chronic diseases such as periodontitis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present two physical layer secure transmission schemes for multi-user multi-relay networks, where the communication from M users to the base station is assisted by direct links and by N decode-and-forward relays. In this network, we consider that a passive eavesdropper exists to overhear the transmitted information, which entails exploiting the advantages of both direct and relay links for physical layer security enhancement. To fulfill this requirement, we investigate two criteria for user and relay selection and examine the achievable secrecy performance. Criterion I performs a joint user and relay selection, while Criterion II performs separate user and relay selections, with a lower implementation complexity. We derive a tight lower bound on the secrecy outage probability for Criterion I and an accurate analytical expression for the secrecy outage probability for Criterion II. We further derive the asymptotic secrecy outage probabilities at high transmit signal-to-noise ratios and high main-to-eavesdropper ratios for both criteria. We demonstrate that the secrecy diversity order is min (MN, M + N) for Criterion I, and N for Criterion II. Finally, we present numerical and simulation results to validate the proposed analysis, and show the occurrence condition of the secrecy outage probability floor

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Spectroscopic studies of line emission intensities and ratios offer an attractive option in the\r\ndevelopment of non-invasive plasma diagnostics. Evaluating ratios of selected He I line\r\nemission profiles from the singlet and triplet neutral helium spin systems allows for simultaneous\r\nmeasurement of electron density (ne) and temperature (Te) profiles. Typically, this powerful\r\ndiagnostic tool is limited by the relatively long relaxation times of the 3S metastable term of helium\r\nthat populates the triplet spin system, and on which electron temperature sensitive lines are based.\r\nBy developing a time dependent analytical solution, we model the time evolution of the two spin\r\nsystems. We present a hybrid time dependent/independent line ratio solution that improves the\r\nrange of application of this diagnostic technique in the scrape-off layer (SOL) and edge plasma\r\nregions when comparing it against the current equilibrium line ratio helium model used at\r\nTEXTOR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background
Fluid administration to critically ill patients remains the subject of considerable controversy. While intravenous fluid given for resuscitation may be life-saving, a positive fluid balance over time is associated with worse outcomes in critical illness. The aim of this systematic review is to summarise the existing evidence regarding the relationship between fluid administration or balance and clinically important patient outcomes in critical illness.

Methods
We will search Medline, EMBASE, the Cochrane Central Register of Controlled Trials from 1980 to the present and key conference proceedings from 2009 to the present. We will include studies of critically ill adults and children with acute respiratory distress syndrome (ARDS), sepsis and systemic inflammatory response syndrome (SIRS). We will include randomised controlled trials comparing two or more fluid regimens of different volumes of fluid and observational studies reporting the relationship between volume of fluid administered or fluid balance and outcomes including mortality, lengths of intensive care unit and hospital stay and organ dysfunction. Two independent reviewers will assess articles for eligibility, data extraction and quality appraisal. We will conduct a narrative and/or meta-analysis as appropriate.

Discussion
While fluid management has been extensively studied and discussed in the critical care literature, no systematic review has attempted to summarise the evidence for post-resuscitation fluid strategies in critical illness. Results of the proposed systematic review will inform practice and the design of future clinical trials.

Systematic review registration
PROSPERO CRD42013005608. (http://​www.​crd.​york.​ac.​uk/​PROSPERO/​)