1000 resultados para rotational band


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal analysis, impedance spectroscopy, NMR and Raman spectroscopy have been used to investigate the plastic crystal dimethylpyrrolidinium thiocyanate in order to gain further insight into the properties of organic ionic plastic crystals. This compound has a solid–solid phase transition at 82 °C, and melts at 122 °C. A step increase in conductivity of about one order of magnitude is observed at the phase transition, followed by a decrease in activation energy for conduction. A large entropy gain occurs at the II → I transition, and 1H NMR linewidth measurements together with second moment calculations showed that the dimethylpyrrolidinium cation goes from a static state, to full isotropic tumbling. Raman measurements confirm that the cation as well as the anion exhibit increased rotational mobility when entering phase I.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evolution of adiabatic shear localization in commercial titanium subjected to heavy cold rolling was investigated. The evolution of the morphology, microhardness, local shear strain, and local temperature increments were systematically studied and estimated. A shear band with about 25m in width was formed and fine nanograins with a range of dimensions varying from 20 to 160nm and had a mean size of about 70nm were observed inside the centre of shear band after 83% cold-rolling. Microhardness test shows that hardness within the shear band is markedly higher than that of the surrounding matrix. The calculated shear strain and maximum temperature increase within the shear band are much higher than that of the overall deformed sample. The initiation of shear localization may depend on geometric perturbation instead of thermal ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Delayed presentation of retained intraocular foreign body is a diagnostic and therapeutic challenge to the ophthalmologist. Herein a case of a man presenting 25 five years after initial injury with a retained metallic foreign body adjacent to the optic disc is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High levels of readiness to change (RTC) are considered critical to the long-term success of weight management programs including bariatric surgery. However, there are no data to support this assertion. We hypothesize that RTC level will not influence weight outcomes following surgery. In 227 consecutive patients undergoing adjustable gastric banding surgery, we recorded reasons for seeking surgery, and RTC measured with the University of Rhode Island Change Assessment. Scores were blinded until study completion. The primary outcome measure was percentage of excess BMI loss at 2 years (%EBMIL-2); others included compliance and surgical complications. Of 227 subjects, 204 (90%) had weight measurement at 2 years. There was no significant correlation between RTC score and %EBMIL-2 (r = 0.047, P = 0.5). Using the median split for RTC score the lowest 102 subjects mean %EBMIL-2 was 52.9 ± 26.9% and the highest 52.2 ± 28.3%, P = 0.869. There was no weight loss difference between highest and lowest quartiles, or a nonlinear relationship between weight loss and RTC score. There was no significant relationship between RCT score and compliance, or likelihood of complications. Those motivated by appearance were more likely to be younger women who lost more weight at 2 years. Poor attendance at follow-up visits was associated with less weight loss, especially in men. Measures of RTC did not predict weight loss, compliance, or surgical complications. Caution is advised when using assessments of RTC to predict outcomes of bariatric surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of experiments was conducted to evaluate the degree of band broadening in very high pressure LC due to column connections. Different column manufacturers use slightly different designs for their column fittings. If the same column connections are repeatedly used to attach columns of different origins, different void volumes form between capillary tubes and column inlets. An Agilent Ultra Low Dispersion Kit (tubing id 75 μm) was installed on an Agilent Infinity 1290 ultra HPLC and used to connect successively an Agilent, a Phenomenex, and a Waters column. A series of uracil (unretained) samples were injected and eluted at a wide range of flow rates with a water/acetonitrile mixture as eluent. In order to determine the variance contribution from column connections as accurately as possible a nonretained probe compound was selected because the variance contribution from the column is the smallest for analytes, which have very low k values. Yet, this effect still has an impact on the resolution for moderately retained compounds (k > 2) for narrow-bore columns packed with fine particles, since variance contributions are additive for linear chromatographic systems. Each injection was replicated five times under the same experimental conditions. Then NanoViper column connections (tubing id 75 μm) were used and the same injections were made. This system was designed to minimize connection void volumes for any column. Band variances were calculated as the second central moment of elution peaks and used to assess the degree of band broadening due to the column connections. Band broadening may increase from 3.8 to 53.9% when conventional metal ferrules were used to join columns to connection sites. The results show that the variance contribution from improper connections can generate as much as 60.5% of the total variance observed. This demonstrates that column connections can play a larger role than the column packing with respect to band dispersion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing the capacitance ratio in RF MEMS shunt capacitive switch will increase its RF performance but also raise its actuation voltage. To improve the RF performance of the switch without increasing its capacitance ratio, this paper explores two methods: reducing the LC resonance from the mm-wave into the X-band by using an inductive bridge, and using two short high impedance transmission lines at both ends of the CPW line. Accordingly, this paper presents the design and simulation of an electro-static low actuation voltage and a very high isolation multipurpose switch with a very large bandwidth. The simulation results are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a wide band RF MEMS capacitive switch. The LC resonant frequency is reduced from mm wave to X band frequencies at down-state by using a meander type membrane, with the frequency band is being increased by adding two short high impedance lines at both ends of coplanar waveguide (CPW). Moreover, this acts as T-match circuit in up-state position and improves the matching. Simulation results demonstrate that the capacitance ratio reduces from 50 to 21.4, S21 and S11 are less than −10dB for the entire frequency band at down-state and up-state. Also, a comprehensive and complete electric model of the switch is proposed and simulation results agree well with the characteristics of the physical structure of the MEMS switch. Vpull-in and Vpull-out of this switch are 8.1V and 0.3V, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel adaptive safe-band for quantization based audio watermarking methods, aiming to improve robustness. Considerable number of audio watermarking methods have been developed using quantization based techniques. These techniques are generally vulnerable to signal processing attacks. For these conventional quantization based techniques, robustness can be marginally improved by choosing larger step sizes at the cost of significant perceptual quality degradation. We first introduce fixed size safe-band between two quantization steps to improve robustness. This safe-band will act as a buffer to withstand certain types of attacks. Then we further improve the robustness by adaptively changing the size of the safe-band based on the audio signal feature used for watermarking. Compared with conventional quantization based method and the fixed size safe-band based method, the proposed adaptive safe-band based quantization method is more robust to attacks. The effectiveness of the proposed technique is demonstrated by simulation results. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parallel manipulators provide several benefits compared to serial manipulators of similar size. These advantages typically include higher speed and acceleration, improved position accuracy and increased stiffness. However, parallel manipulators also suffer from several disadvantages. These drawbacks commonly include a small ratio of the positional workspace relative to the manipulator footprint and a limited rotational capability of the manipulated platform. A few parallel manipulators featuring a large ratio of the positional workspace relative to the footprint have been proposed. This paper investigates the feasibility of employing gearing to extend the range of the end-effector rotation of such mechanisms. The objective is to achieve parallel manipulators where both the positional and rotational workspace are comparable to that of serial manipulators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Timber harvesting is a common global disturbance that has important effects on the ability of forests to provide ecosystems services and retain biodiversity. Using predictive frameworks to examine biodiversity responses to logging could assist in retaining natural forest values. The intermediate disturbance hypothesis (IDH) and the habitat accommodation model (HAM) potentially offer frameworks for explaining different coarse scale community responses to logging. We used a 60. year post-logging chronosequence to investigate small reptile community responses to age post-logging in temperate forests using three metrics (species richness, evenness and relative abundance). First, we evaluated if variation in these metrics adhered to prior predictions, including the IDH. Second, we evaluated how age post-logging influence community responses through fine scale vegetation elements. Third, we evaluated support for the HAM by measuring compositional change (species turnover) of small reptile community to age post-logging. Reptile relative abundance exhibited a curvilinear relationship to age since logging, contradicting our prior prediction of sustained increase. Species richness and evenness were unrelated to age since logging thus providing no support to IDH and other prior predictions. Relative abundance and richness did not relate to any vegetation characteristic tested. These metrics were also unrelated to logging method. Community composition was marginally significantly influenced by age since logging, thus supporting the HAM. Our results suggest that forest reptiles exposed to logging exhibit variable changes depending on the community metric in question, and that different approaches, including those based on species traits, are needed to improve evaluating disturbance related biodiversity responses.