961 resultados para junior synonym


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate the antibacterial efficacy of irrigating solutions and their combinations against Enterococcus faecalis. Study design. One hundred ten single-rooted human teeth were inoculated with E. faecalis and incubated for 21 days. Teeth were divided according to the irrigant: Group I (GI), 2.5% sodium hypochlorite solution (NaOCl); GII, 2.5% NaOCl + 10% citric acid; GIII, 2.5% NaOCl + apple cider vinegar; GIV, apple cider vinegar; GV, 2% chlorhexidine solution; GVI, 1% peracetic acid; GVII, saline solution. Microbiological samples were taken after root canal preparation and 7 days later. Data were submitted to ANOVA (5%). Results. All solutions promoted reduction of E. faecalis after instrumentation, but bacterial counts were higher in the final sample. GI, GV, and GVI had lower bacterial counts than the other groups. Conclusions. The irrigating solutions may present activity but do not eradicate E. faecalis in the root canal system. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112:396-400)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the flow rate of 3 endodontic sealers: Sealer 26, AH Plus, and MTA Obtura. Study design. According to the method proposed by the American Dental Association (ADA specification no. 57), the sealers were placed between 2 glass slabs under a weight of 120 g. The diameters of the formed discs were measured with a digital paquimeter. The test was repeated 5 times for each sealer. Results. The results were expressed as arithmetic means, and the statistical analysis was performed through Tukey test. AH Plus showed significantly superior flow rate compared with Sealer 26 and MTA Obtura. There was no statistically significant difference between flow rates presented by Sealer 26 and MTA Obtura. Conclusion. Within the limitations of this in vitro study, it was concluded that all of the the endodontic sealers tested presented greater flow than the minimum recommended in the ADA 57 specification. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;109:e47-e49)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared ultrasonic chemical vapor deposition (CVD)-coated tip (CVDentus #8.1117-1; Clorovale Diamantes Ind. e Com. Ltda Epp, Sao Jose dos Campos, SP, Brazil) versus high-speed (#FG700L) and low-speed (#699) carbide burs for apicoectomy, evaluating the time required for resection and analyzing the root-end surfaces by scanning electron microscopy. Thirty extracted human premolars had the canals instrumented and obturated and were randomly assigned to 3 groups (n = 10), according to the instrument used for root-end resection. The time required for resection of the apical 2 mm of each root was recorded. The resected apical segments were dried, sputter coated with gold, and examined with a scanning electron microscope at X 350 magnification. A four-point (0-3) scoring system was used to evaluate the apical surface smoothness. The results were analyzed statistically by the Kruskal-Wallis test and two-by-two comparisons analyses were performed using the Miller test. The significance level was set at 5%. Root-end resection with the high-speed bur was significantly faster (p < 0.05) compared with the low-speed bur and CVD tip. The carbide burs produced significantly smoother root-end surfaces than the CVD tip (p < 0.05). The low-speed bur produced the smoothest root-end surfaces, whereas the roughest and most irregular root ends (p < 0.05) were obtained with the CVD tip. However, no statistically significant difference (p > 0.05) was found between the high- and low-speed burs regarding the surface roughness of the resected root ends (p > 0.05). In conclusion, under the tested conditions, ultrasonic root-end resection took a longer time and resulted in rougher surfaces compared with the use of carbide burs at both high and low speed. (J Endod 2009;35:265-268)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling. Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05). Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps. Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the long-term influence of xenogenic grafts on bone crestal height and radiographic density following extraction of teeth. The right and left third lower molars of 22 patients were surgically extracted, and one randomly chosen socket was filled with a xenogenic graft (Gent-Tech). The contralateral molar was left to heal naturally, serving as a paired control. Digital intraoral radiographies were taken at surgery and 2, 6, and 24 months after, to evaluate bone density (BD) and alveolar bone crest to cementoenamel junction distance. The data obtained were subjected to two-way analysis of variance and Tukey`s test (alpha = 0.05). The significant decrease in cementoenamel junction distance observed for both groups was limited to the first 6 months. BD values increased significantly in the first 6 months, with no alterations observed up to 24 months for both groups. BD was higher for the experimental group at all time points (p < 0.05). Socket grafting with the xenogenic materials tested did not changed bone crestal height and bone radiographic density in the long term.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dry socket is one of the most studied complications in dentistry, and a great number of studies have searched for an effective and safe method for its prevention and treatment. One of the great clinical challenges since the first case was reported has been the inconsistency and differences in the various definitions of dry socket and the criteria used for diagnosis. The pathophysiology, etiology, prevention, and treatment of dry socket are very important in the practice of oral surgery. The aim of the present report was to review and discuss each aspect. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:1922-1932, 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the biomechanical and microscopic response of previously grafted bone to titanium implants. The lower incisors of 16 rabbits were surgically extracted, and bilateral perforations communicating with the remaining sockets were created distally. A socket/perforation defect on each mandible was chosen at random to be immediately filled with a xenogenic graft, whereas the contralateral perforation was left to heal naturally and served as a paired control. After 60 days, titanium implants were installed in the previously operated areas. After periods of 2 and 6 months, the animals were killed, and the force necessary to retrieve implants as well as the bone-implant contact (BIC) and bone mass (BM) were quantified and statistically compared by 2-way analysis of variance and Tukey`s test (alpha = .05). No significant differences in removal torque were observed, either by time or by treatment condition. Differences in BIC and BM between experimental and control groups were not statistically significant through the intervals studied (P < .05). The presence of a xenogenic graft did not influence the microscopic tissue response to titanium implants or fixation into newly formed or mature bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the orthodontic treatment of a patient with Klippel-Trenaunay-Weber syndrome (KTWS) who received orthodontic treatment that included rapid palatal expansion and orthognathic surgery. There is no report in the literature with this orthodontic treatment protocol, that was considered successful. The pros and cons of this approach as well as the risks involved are discussed. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e17-e25)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study examined the retention of solvents within experimental HEMA/solvent primers after two conditions for solvent evaporation: from a free surface or from dentine surface. Methods: Experimental primers were prepared by mixing 35% HEMA with 65% water, methanol, ethanol or acetone (v/v). Aliquots of each primer (50 mu l) were placed on glass wells or they were applied to the surface of acid-etched dentine cubes (2 mm x 2 mm x 2 mm) (n = 5). For both conditions (i.e. from free surface or dentine cubes), change in primers mass due to solvent evaporation was gravimetrically measured for 10 min at 51% RH and 21 degrees C. The rate of solvent evaporation was calculated as a function of loss of primers mass (%) over time. Data were analysed by two-way ANOVA and Student-Newman-Keuls (p < 0.05). Results: There were significant differences between solvent retention(%) and evaporation rate (%/min) depending on the solvent present in the primer and the condition for evaporation (from free surface or dentine cubes) (p < 0.05). For both conditions, the greatest amount of retained solvent was observed for HEMA/water primer. The rate of solvent evaporation for HEMA/acetone primer was almost 2- to 10-times higher than for HEMA/water primer depending whether evaporation occurred, respectively, from a free surface or dentine cubes. The rate of solvent evaporation varied with time, being in general highest at the earliest periods. Conclusions: The rate of solvent evaporation and its retention into HEMA/solvent primers was influenced by the type of the solvent and condition allowed for their evaporation. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Osny Ferreira-Junior, Luciana Dorigatti de Avila, Marcelo Bonifacio da Silva Sampieri, Eduardo Dias-Ribeiro, Weiliang Chen, Song Fan. Impacted Lower Third Molar Fused with a Supernumerary Tooth-Diagnosis and Treatment Planning Using Cone-Beam Computed Tomography. International Journal of Oral Science, 1(4): 224-228, 2009 This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radiography was complemented by the Donovan`s radiographic technique; but because of the proximity of the dental element to the mandibular ramus, it was not possible to have a final fusion diagnosis. Hence, the Cone-Beam Computed Tomography-which provides precise three-dimensional information-was used to determinate the fusion diagnosis and also to help in the surgical planning. In this case report we observed that the periapical, occlusal and panoramic were not able to show details which could only be examined through the cone-beam computed tomography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: The aim of this study was to evaluate the vestibular-palatal diffusion of 4% articaine with epinephrine 1: 100,000 and 1: 200,000, in impacted maxillary third molar extractions, without palatal injection. Materials and Method: Two hundred teeth were selected from patients age 15 to 46. Patients were divided into 4 groups: 1A, were anesthetized with 4% articaine 1: 100,000 and the surgery was initiated 5 minutes following anesthesia. 1B, used 4% articaine 1: 100,000 but the surgery was started 10 minutes after anesthesia. 2A, used 4% articaine 1: 200,000 the surgery was started 5 minutes after. 2B, used 4% articaine 1: 200,000 but 10 minutes was allowed for anesthetic diffusion before the initiation of in groups (50 extractions each) only buccal vestibule anesthesia was initially administered (i.e. no palatal injections were used). Results: The rate of sufficient vestibule-palatal diffusion, as determined by the lack of necessity of supplemental palatal anesthesia, was: 1A(84%), 1B(98%), 2A(78%), 2B(82%). Chi-square (X2) and residual analyses showed that a higher vestibule-palatal diffusion was obtained using 4% articaine 1: 100,000 with a period of 10 minutes (p<0.05). Conclusions: Most of the extractions could be performed only with vestibule anesthesia. However, vasoconstrictor concentration and the time interval between administration of the anesthetic and initiation of surgery did influence buccal vestibule-palatal diffusion of 4% articaine in the extraction models used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study compared the clinical efficacy of 4% articaine (A200) and 0.5% bupivacaine (B200), both with 1: 200,000 epinephrine, for lower third molar removal. Study design: Fifty patients underwent removal of symmetrically positioned lower third molars, in 2 separate appointments, under local anesthesia either with A200 or B200, in a double-blind, randomized, and crossover manner. Time to onset, duration of postoperative analgesia, duration of anesthetic action on soft tissues, intraoperative bleeding, and hemodynamic parameters were evaluated. Results: A statistically significant difference between the time to onset of A200 (1.66 +/- 0.13 minutes) and B200 (2.51 +/- 0.21 minutes) was found (P < .05). There was no statistically significant difference in the duration of analgesia, whether the patient was subjected to osteotomy or not, regardless of the local anesthetic used (3 to 4 hours; P < .05). However, when patients received B200 they experienced a statistically significant longer period of anesthesia on the soft tissues as compared with when they had received A200 (around 5 hours and 4 hours, respectively, P < .05). The surgeon`s rating of intraoperative bleeding was considered very close to minimal for both anesthetics. In the surgeries with osteotomy, the comparison between A200 and B200 showed statistically significant differences in the diastolic (64 mm Hg and 68 mm Hg, respectively, P = .001) and mean arterial pressure (86 mm Hg and 89 mm Hg, respectively, P = .031) when data from all the surgical phases were pooled. Additionally, the mouth opening at the suture removal was statistically different for A200 and B200 solutions (91.90% +/- 3.00% and 88.57% +/- 2.38% of the preoperative measure, respectively) when surgeries required bone removal (P < .05). Conclusions: In comparison with 0.5% bupivacaine, 4% articaine (both with 1: 200,000 epinephrine) provided a shorter time to onset and comparable hemostasis and postoperative pain control with a shorter duration of soft tissue anesthesia in lower third molar removal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Up-regulated matrix metalloproteinases may be involved in the development of cardiomyocyte injury and the degradation of troponin associated with acute pulmonary thromboembolism. We examined whether pretreatment with doxycycline (a nonspecific matrix metalloproteinase inhibitor) protects against cardiomyocyte injury associated with acute pulmonary thromboembolism. Design: Controlled animal study. Setting: University research laboratory. Subjects: Mongrel dogs. Interventions: Anesthetized animals received doxycycline (10 mg/kg intravenously) or saline and acute pulmonary thromboembolism was induced with autologous blood clots injected into the right atrium. Control animals received doxycycline (or saline). Measurements and Main Results: Hemodynamic measurements were performed, and acute pulmonary thromboembolism increased baseline mean pulmonary arterial pressure and pulmonary vascular resistance by approximately 160% and 362%, respectively (both p<.05), 120 mins after acute pulmonary thromboembolism. Pretreatment with doxycycline attenuated these increases (to 125% and 232%, respectively; both p<.05). Although acute pulmonary thromboembolism tended to increase the right ventricle maximum rate of isovolumic pressure development and the maximum rate of isovolumic pressure decay, doxycycline produced no effects on these parameters. Gelatin zymograms of right ventricle showed that acute pulmonary thromboembolism marginally increased matrix metalloproteinase-9 (but not matrix metalloproteinase-2) levels in the right ventricle. A fluorometric assay to assess net matrix metalloproteinase activities showed that acute pulmonary thromboembolism increased matrix metalloproteinase activities in the right ventricle by >100% (p<.05), and this finding was confirmed by in situ zymography of the right ventricle. Doxycycline attenuated acute pulmonary thromboembolism-induced increases in right ventricle matrix metalloproteinase activities. Acute pulmonary thromboembolism induced neutrophil accumulation in the right ventricle, as estimated by myeloperoxidase activity, and doxycycline blunted this effect (p<.05). Serum cardiac troponin I concentrations, which reflect cardiomyocyte injury, increased after acute pulmonary thromboembolism, and this increase was attenuated by pretreatment with doxycycline (p<.05). Conclusions: We found evidence supporting the idea that acute pulmonary thromboembolism is associated with increased matrix metalloproteinase activities in the right ventricle, which may lead to degradation of sarcomeric proteins, including cardiac troponin I. Inhibition of matrix metalloproteinases may be an effective therapeutic intervention in the management of acute pulmonary thromboembolism. (Crit Care Med 2011; 39: 349-356)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently, the combination of cisplatin and gemcitabine is considered a standard chemotherapeutic protocol for bladder cancer. However, the mechanism by which these drugs act on tumor cells is not completely understood. The aim of the present study was to investigate the effects of these two antineoplastic drugs on the apoptotic index and cell cycle kinetics of urinary bladder transitional carcinoma cell lines with wild-type or mutant TP53 (RT4: wild type for TP53; 5637 and T24: mutated TP53). Cytotoxicity, cell survival assays, clonogenic survival assays and flow cytometric analyses for cell cycle kinetics and apoptosis detection were performed with three cell lines treated with different concentrations of cisplatin and gemcitabine. G(1) cell cycle arrest was observed in the three cell lines after treatment with gemcitabine and gemcitabine plus cisplatin. A significant increase in cell death was also detected in all cell lines treated with cisplatin or gemcitabine. Lower survival rates occurred with the combined drug protocol independent of TP53 status. TP53-wild type cells (RT4) were more sensitive to apoptosis than were mutated TP53 cells when treated with cisplatin or gemcitabine. Concurrent treatment with cisplatin and gemcitabine was more effective on transitional carcinoma cell lines than either drug alone; the drug combination led to a decreased cell survival that was independent of TP53 status. Therefore, the synergy between low concentrations of cisplatin and gemcitabine may have clinical relevance, as high concentrations of each individual drug are toxic to whole organisms.