990 resultados para energy education


Relevância:

20.00% 20.00%

Publicador:

Resumo:

As manufacturers face an increasingly competitive environment, they seek out opportunities to reduce production costs without negatively affecting the yield or the quality of their finished products. The challenge of maintaining high product quality while simultaneously reducing production costs can often be met through investments in energy efficient technologies and energy efficiency practices. Energy management systems can offer both technological and best practice efficiencies in order to achieve substantial savings. A strong energy management system provides a solid foundation for an organisation to reduce production costs and improve site efficiency. The I.S EN16001 energy management standard specifies the requirements for establishing, implementing, maintaining and improving an energy management system and represents the latest best practice for energy management in Ireland. The objective of the energy management system is to establish a systematic approach for improving energy performance continuously. The I.S EN16001 standard specifies the requirements for continuous improvement through using energy more efficiently. The author analysed how GlaxoSmithKline’s (GSK) pharmaceutical manufacturing facility in Cork implemented the I.S. EN16001 energy management system model, and defined how energy saving opportunities where identified and introduced to improve efficiency performance. The author performed an extensive literature research in order to determine the current status of the pharmaceutical industry in Ireland, the processes involved in pharmaceutical manufacturing, the energy users required for pharmaceutical manufacturing and the efficiency measures that can be applied to these energy users in order to reduce energy consumption. The author then analysed how energy management standards are introduced to industry and critically analysed the driving factors for energy management performance in Ireland through case studies. Following an investigation as to how the I.S. EN16001 energy management standard is operated in GSK, a critical analysis of the performance achieved by the GSK energy management system is undertaken in order to determine if implementing the I.S EN16001 standard accelerates achieving energy savings. Since its introduction, the I.S. EN16001 model for energy management has enabled GSK to monitor, target and identify energy efficiency opportunities throughout the site. The model has put in place an energy management system that is continuously reviewed for improvement and to date has reduced GSK’s site operations cost by over 30% through technical improvements and generating energy awareness for smarter energy consumption within the GSK Cork site. Investment in I.S. EN16001 has proved to be a sound business strategy for GSK especially in today's manufacturing environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A composting Heat Extraction Unit (HEU) was designed to utilise waste heat from decaying organic matter for a variety of heating application The aim was to construct an insulated small scale, sealed, organic matter filled container. In this vessel a process fluid within embedded pipes would absorb thermal energy from the hot compost and transport it to an external heat exchanger. Experiments were conducted on the constituent parts and the final design comprised of a 2046 litre container insulated with polyurethane foam and kingspan with two arrays of qualpex piping embedded in the compost to extract heat. The thermal energy was used in horticultural trials by heating polytunnels using a radiator system during a winter/spring period. The compost derived energy was compared with conventional and renewable energy in the form of an electric fan heater and solar panel. The compost derived energy was able to raise polytunnel temperatures to 2-3°C above the control, with the solar panel contributing no thermal energy during the winter trial and the electric heater the most efficient maintaining temperature at its preset temperature of 10°C. Plants that were cultivated as performance indicators showed no significant difference in growth rates between the heat sources. A follow on experiment conducted using special growing mats for distributing compost thermal energy directly under the plants (Radish, Cabbage, Spinach and Lettuce) displayed more successful growth patterns than those in the control. The compost HEU was also used for more traditional space heating and hot water heating applications. A test space was successfully heated over two trials with varying insulation levels. Maximum internal temperature increases of 7°C and 13°C were recorded for building U-values of 1.6 and 0.53 W/m2K respectively using the HEU. The HEU successfully heated a 60 litre hot water cylinder for 32 days with maximum water temperature increases of 36.5°C recorded. Total energy recovered from the 435 Kg of compost within the HEU during the polytunnel growth trial was 76 kWh which is 3 kWh/day for the 25 days when the HEU was activated. With a mean coefficient of performance level of 6.8 calculated for the HEU the technology is energy efficient. Therefore the compost HEU developed here could be a useful renewable energy technology particularly for small scale rural dwellers and growers with access to significant quantities of organic matter

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quality Management is a well-developed and widely used approach within industry to gain competitive edge and increased market share. It is a new management approach for schools who are now applying it without having the culture or experience of its evolution. Industrially based Quality management systems and excellence models have been developed. These excellence models and frameworks are based on the principles and concepts of TQM which are recognised as essential elements of high performing organisations. Schools are complex social institutions that provide a service. Like any other service industry, the customers of education are expecting and demanding a better service or else they will go elsewhere. Schools are beginning to reform and change to adapt to such demands. This has been reflected in Ireland in the Education Act, 1998. It is now the right time to develop a quality management system specifically for schools. The existing industrial excellence models have been modified for use in the private and public sector and some have been specifically tailored for education. The problem with such models is that they are still too sophisticated and the language still too industrial for schools. This Thesis develops and Excellence Model for Second Level Schools and provides guidance and school specific tools for its implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes a search for very high energy (VHE) gamma-ray emission from the starburst galaxy IC 342. The analysis was based on data from the 2003 — 2004 observing season recorded using the Whipple 10-metre imaging atmospheric Cherenkov telescope located on Mount Hopkins in southern Arizona. IC 342 may be classed as a non-blazar type galaxy and to date only a few such galaxies (M 87, Cen A, M 82 and NGC 253) have been detected as VHE gamma-ray sources. Analysis of approximately 24 hours of good quality IC 342 data, consisting entirely of ON/OFF observations, was carried out using a number of methods (standard Supercuts, optimised Supercuts, scaled optimised Supercuts and the multivariate kernel analysis technique). No evidence for TeV gamma-ray emission from IC 342 was found. The significance was 0.6 a with a nominal rate of 0.04 ± 0.06 gamma rays per minute. The flux upper limit above 600 GeV (at 99.9 % confidence) was determined to be 5.5 x 10-8 m-2 s-1, corresponding to 8 % of the Crab Nebula flux in the same energy range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Network protection, distribution networks, decentralised energy resources, communication links, IEC Communication and Substation Control Standards

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cardiovascular diseases are the current leading causes of death and disability globally. Objective: To assess the effects of a basic educational program for cardiovascular prevention in an unselected outpatient population. Methods: All participants received an educational program to change to a healthy lifestyle. Assessments were conducted at study enrollment and during follow-up. Symptoms, habits, ATP III parameters for metabolic syndrome, and American Heart Association’s 2020 parameters of cardiovascular health were assessed. Results: A total of 15,073 participants aged ≥ 18 years entered the study. Data analysis was conducted in 3,009 patients who completed a second assessment. An improvement in weight (from 76.6 ± 15.3 to 76.4 ± 15.3 kg, p = 0.002), dyspnea on exertion NYHA grade II (from 23.4% to 21.0%) and grade III (from 15.8% to 14.0%) and a decrease in the proportion of current active smokers (from 3.6% to 2.9%, p = 0.002) could be documented. The proportion of patients with levels of triglycerides > 150 mg/dL (from 46.3% to 42.4%, p < 0.001) and LDL cholesterol > 100 mg/dL (from 69.3% to 65.5%, p < 0.001) improved. A ≥ 20% improvement of AHA 2020 metrics at the level graded as poor was found for smoking (-21.1%), diet (-29.8%), and cholesterol level (-23.6%). A large dropout as a surrogate indicator for low patient adherence was documented throughout the first 5 visits, 80% between the first and second assessments, 55.6% between the second and third assessments, 43.6% between the third and fourth assessments, and 38% between the fourth and fifth assessments. Conclusion: A simple, basic educational program may improve symptoms and modifiable cardiovascular risk factors, but shows low patient adherence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2015