969 resultados para customer based
Resumo:
Red, green and blue optical signals were directed to an a-SiC:H multilayered device, each one with a specific transmission rate. The combined optical signal was analyzed by reading out, under different applied voltages, the generated photocurrent. Results show that when a chromatic time dependent wavelength combination with different transmission rates irradiates the multilayered structure, the device operates as a tunable wavelength filter and can be used in wavelength division multiplexing systems for short range communications. An application to fluorescent proteins detection is presented. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Resumo:
Antibodies against gliadin are used to detect celiac disease (CD) in patients. An electrochemical immunosensor for the voltammetric detection of human anti-gliadin antibodies (AGA) IgA and AGA IgG in real serum samples is proposed. The transducer surface consists of screen-printed carbon electrodes modified with a carbon nanotube/gold nanoparticle hybrid system, which provides a very useful surface for the amplification of the immunological interactions. The immunosensing strategy is based on the immobilization of gliadin, the antigen for the autoantibodies of interest, onto the nanostructured surface. The antigen–antibody interaction is recorded using alkaline phosphatase labeled anti-human antibodies and a mixture of 3-indoxyl phosphate with silver ions (3-IP/Ag+) was used as the substrate. The analytical signal is based on the anodic redissolution of the enzymatically generated silver by cyclic voltammetry. The electrochemical behavior of this immunosensor was carefully evaluated assessing aspects as sensitivity, non-specific binding and matrix effects, and repeatability and reproducibility. The results were supported with a commercial ELISA test.
Resumo:
OBJECTIVE: A cross-sectional population-based study was conducted to assess, in active smokers, the relationship of number of cigarettes smoked and other characteristics to salivary cotinine concentrations. METHODS: A random sample of active smokers aged 15 years or older was selected using a stepwise cluster sample strategy, in the year 2000 in Rio de Janeiro, Brazil. The study included 401 subjects. Salivary cotinine concentration was determined using gas chromatography with nitrogen-phosphorus detection. A standard questionnaire was used to collect demographic and smoking behavioral data. The relation between the number of cigarettes smoked in the last 24h and cotinine level was examined by means of a nonparametric fitting technique of robust locally weighted regression. RESULTS: Significantly (p<0.05) higher adjusted mean cotinine levels were found in subjects smoking their first cigarette within five minutes after waking up, and in those smoking 1-20 cigarettes in the last 24h who reported inhaling more than ½ the time. In those smoking 1-20 cigarettes, the slope was significantly higher for those subjects waiting for more than five minutes before smoking their first cigarette after waking up, and those smoking "light" cigarettes when compared with their counterparts. These heterogeneities became negligible and non-significant when subjects with cotinine >40 ng/mL per cigarette were excluded. CONCLUSIONS: There was found a positive association between self-reporting smoking five minutes after waking up, and inhaling more than ½ the time are consistent and higher cotinine levels. These can be markers of dependence and higher nicotine intake. Salivary cotinine proved to be a useful biomarker of recent smoking and can be used in epidemiological studies and smoking cessation programs.
Resumo:
OBJECTIVE: To assess the association between regular physical activity in adolescence and leisure-time physical activity in adulthood, with emphasis on gender differences. METHODS: A population-based cross-sectional study was carried out in Pelotas, Southern Brazil, in 2003. A representative sample of households was selected in multiple stages and subjects aged 20-59 years were interviewed. Leisure-time physical activity was evaluated using the International Physical Activity Questionnaire. Data on adolescent physical activity were based on subjects' recall. RESULTS: Of 2,577 subjects interviewed, 27.5% were classified as adequately active, and 54.9% reported regular physical activity in adolescence. Subjects who engaged in regular physical activity during adolescence were more likely to be adequately active in adulthood (adjusted prevalence ratio 1.42; 95% CI: 1.23; 1.65). This effect was stronger in women (adjusted prevalence ratio: 1.51; 95% CI: 1.22; 1.86) than men (adjusted prevalence ratio: 1.35; 95% CI: 1.10; 1.67). CONCLUSIONS: Promoting physical activity in school age may be a successful intervention against the epidemic of adult inactivity. Although women were less likely to report regular physical activity in adolescence, the effect of this experience on adult behavior was stronger than in men.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
In this paper we present results on the use of a multilayered a-SiC:H heterostructure as a wavelength-division demultiplexing device (WDM) for the visible light spectrum. The WDM device is a glass/ITO/a-SiC:H (p-i-n)/ a-SiC:H(-p) /Si:H(-i)/SiC:H (-n)/ITO heterostructure in which the generated photocurrent at different values of the applied bias can be assigned to the different optical signals. The device was characterized through spectral response measurements, under different electrical bias. Demonstration of the device functionality for WDM applications was done with three different input channels covering wavelengths within the visible range. The recovery of the input channels is explained using the photocurrent spectral dependence on the applied voltage. The influence of the optical power density was also analysed. An electrical model, supported by a numerical simulation explains the device operation. Short range optical communications constitute the major application field, however other applications are also foreseen.
Resumo:
Liver steatosis is a common disease usually associated with social and genetic factors. Early detection and quantification is important since it can evolve to cirrhosis. In this paper, a new computer-aided diagnosis (CAD) system for steatosis classification, in a local and global basis, is presented. Bayes factor is computed from objective ultrasound textural features extracted from the liver parenchyma. The goal is to develop a CAD screening tool, to help in the steatosis detection. Results showed an accuracy of 93.33%, with a sensitivity of 94.59% and specificity of 92.11%, using the Bayes classifier. The proposed CAD system is a suitable graphical display for steatosis classification.
Resumo:
In this work the identification and diagnosis of various stages of chronic liver disease is addressed. The classification results of a support vector machine, a decision tree and a k-nearest neighbor classifier are compared. Ultrasound image intensity and textural features are jointly used with clinical and laboratorial data in the staging process. The classifiers training is performed by using a population of 97 patients at six different stages of chronic liver disease and a leave-one-out cross-validation strategy. The best results are obtained using the support vector machine with a radial-basis kernel, with 73.20% of overall accuracy. The good performance of the method is a promising indicator that it can be used, in a non invasive way, to provide reliable information about the chronic liver disease staging.
Resumo:
In this work, we present a neural network (NN) based method designed for 3D rigid-body registration of FMRI time series, which relies on a limited number of Fourier coefficients of the images to be aligned. These coefficients, which are comprised in a small cubic neighborhood located at the first octant of a 3D Fourier space (including the DC component), are then fed into six NN during the learning stage. Each NN yields the estimates of a registration parameter. The proposed method was assessed for 3D rigid-body transformations, using DC neighborhoods of different sizes. The mean absolute registration errors are of approximately 0.030 mm in translations and 0.030 deg in rotations, for the typical motion amplitudes encountered in FMRI studies. The construction of the training set and the learning stage are fast requiring, respectively, 90 s and 1 to 12 s, depending on the number of input and hidden units of the NN. We believe that NN-based approaches to the problem of FMRI registration can be of great interest in the future. For instance, NN relying on limited K-space data (possibly in navigation echoes) can be a valid solution to the problem of prospective (in frame) FMRI registration.
Resumo:
In order to overcome the problems associated with low water solubility, and consequently low bioavailability of active pharmaceutical ingredients (APIs), herein we explore a modular ionic liquid synthetic strategy for improved APIs. Ionic liquids containing l-ampicillin as active pharmaceutical ingredient anion were prepared using the methodology developed in our previous work, using organic cations selected from substituted ammonium, phosphonium, pyridinium and methylimidazolium salts, with the intent of enhancing the solubility and bioavailability of l-ampicillin forms. In order to evaluate important properties of the synthesized API-ILs, the water solubility at 25 °C and 37 °C (body temperature) as well as octanol–water partition coefficients (Kow's) and HDPC micelles partition at 25 °C were measured. Critical micelle concentrations (CMC's) in water at 25 °C and 37 °C of the pharmaceutical ionic liquids bearing cations with surfactant properties were also determined from ionic conductivity measurements.
Resumo:
OBJECTIVE: To estimate the spatial intensity of urban violence events using wavelet-based methods and emergency room data. METHODS: Information on victims attended at the emergency room of a public hospital in the city of São Paulo, Southeastern Brazil, from January 1, 2002 to January 11, 2003 were obtained from hospital records. The spatial distribution of 3,540 events was recorded and a uniform random procedure was used to allocate records with incomplete addresses. Point processes and wavelet analysis technique were used to estimate the spatial intensity, defined as the expected number of events by unit area. RESULTS: Of all georeferenced points, 59% were accidents and 40% were assaults. There is a non-homogeneous spatial distribution of the events with high concentration in two districts and three large avenues in the southern area of the city of São Paulo. CONCLUSIONS: Hospital records combined with methodological tools to estimate intensity of events are useful to study urban violence. The wavelet analysis is useful in the computation of the expected number of events and their respective confidence bands for any sub-region and, consequently, in the specification of risk estimates that could be used in decision-making processes for public policies.
Resumo:
Dissertação de Mestrado em Gestão de Empresas/MBA.
Resumo:
An Electrocardiogram (ECG) monitoring system deals with several challenges related with noise sources. The main goal of this text was the study of Adaptive Signal Processing Algorithms for ECG noise reduction when applied to real signals. This document presents an adaptive ltering technique based on Least Mean Square (LMS) algorithm to remove the artefacts caused by electromyography (EMG) and power line noise into ECG signal. For this experiments it was used real noise signals, mainly to observe the di erence between real noise and simulated noise sources. It was obtained very good results due to the ability of noise removing that can be reached with this technique. A recolha de sinais electrocardiogr a cos (ECG) sofre de diversos problemas relacionados com ru dos. O objectivo deste trabalho foi o estudo de algoritmos adaptativos para processamento digital de sinal, para redu c~ao de ru do em sinais ECG reais. Este texto apresenta uma t ecnica de redu c~ao de ru do baseada no algoritmo Least Mean Square (LMS) para remo c~ao de ru dos causados quer pela actividade muscular (EMG) quer por ru dos causados pela rede de energia el ectrica. Para as experiencias foram utilizados ru dos reais, principalmente para aferir a diferen ca de performance do algoritmo entre os sinais reais e os simulados. Foram conseguidos bons resultados, essencialmente devido as excelentes caracter sticas que esta t ecnica tem para remover ru dos.
Resumo:
Este projecto surgiu no contexto da solicitação de um dos clientes da empresa Castros Iluminações que pretendia um sistema de iluminação decorativa (baseada em LED) de dois conjuntos de 288 janelas, pertencendo cada conjunto a uma fachada diferente do edifício. Este sistema teria que prever a possibilidade de controlar a cor de cada janela individualmente, dando ao cliente a possibilidade de alterar o ambiente decorativo das fachadas do edifício. A utilização de comunicação sem fios foi justificada pela necessidade de evitar a quantidade enorme de cabos que seria necessário passar utilizando os sistemas comerciais convencionais e a impossibilidade de os esconder. Esta solução foi pensada para ser implementada num edifício com 14 Andares, facto que por si só inviabiliza a passajem de cabos. Para interligar todos os dispositivos de iluminação decorativa com um controlador portátil, e eliminar os problemas ligados à cablagem, foi utilizado o protocolo de comunicações sem fios ZigBee™. A escolha recaiu neste protocolo devido a factores como os seus baixos consumos, simplicidade do protocolo comparativamente com outras redes e o seu baixo custo. No desenvolvimento deste projecto foi utilizada a stack da Microchip©, versão gratuita, disponibilizada na internet e os seus transceivers de comunicação Zigbee™, MRF24j40MA. Para fazer a interface de comunicação com o utilizador, foi desenvolvida uma aplicação de Software para correr em computadores com ambiente Windows™. Esta aplicação foi desenvolvida em Visual Studio™ utilizando a linguagem C#. Foram efectuados alguns testes para se perceber a eficiência e robustez da comunicação ZigBee™ e apesar do número de dispositivos disponíveis para ensaios ser muito reduzido, foi possível verificar que, mesmo funcionando correctamente, o desempenho do sistema poderá ser melhorado, quer seja a nível da gestão das comunicações, quer a nível do software informático para controlo do ambiente decorativo das fachadas do edifício. O sistema, no actual estado de desenvolvimento, permite controlar a cor dos vários dispositivos da rede através do computador, com uma resolução de 24bits. A aplicação desenvolvida em Visual Studio™ permite controlar de forma simples e intuitiva para o utilizador, a cor do material iluminativo dos vários dispositivos da rede.
Oxidative Leaching of metals from electronic waste with solutions based on quaternary ammonium salts
Resumo:
The treatment of electric and electronic waste (WEEE) is a problem which receives ever more attention. An inadequate treatment results in harmful products ending up in the environment. This project intends to investigate the possibilities of an alternative route for recycling of metals from printed circuit boards (PCBs) obtained from rejected computers. The process is based on aqueous solutions composed of an etchant, either 0.2 M CuCl2.2H2O or 0.2 M FeCl3.6H2O, and a quaternary ammonium salt (quat) such as choline chloride or chlormequat. These solutions are reminiscent of deep eutectic solvents (DES) based on quats. DES are quite similar to ionic liquids (ILs) and are used as well as alternative solvents with a great diversity of physical properties, making them attractive for replacement of hazardous, volatile solvents (e.g. VOCs). A remarkable difference between genuine DES and ILs with the solutions used in this project is the addition of rather large quantities of water. It is shown the presence of water has a lot of advantages on the leaching of metals, while the properties typical for DES still remain. The oxidizing capacities of Cu(II) stem from the existence of a stable Cu(I) component in quat based DES and thus the leaching stems from the activity of the Cu(II)/Cu(I) redox couple. The advantage of Fe(III) in combination with DES is the fact that the Fe(III)/Fe(II) redox couple becomes reversible, which is not true in pure water. This opens perspectives for regeneration of the etching solution. In this project the leaching of copper was studied as a function of gradual increasing water content from 0 - 100w% with the same concentration of copper chloride or iron(III) chloride at room temperature and 80ºC. The solutions were also tested on real PCBs. At room temperature a maximum leaching effect for copper was obtained with 30w% choline chloride with 0.2 M CuCl2.2H2O. The leaching effect is still stronger at 80°C, b ut of course these solutions are more energy consuming. For aluminium, tin, zinc and lead, the leaching was faster at 80ºC. Iron and nickel dissolved easily at room temperature. The solutions were not able to dissolve gold, silver, rhodium and platinum.