999 resultados para cross-sensitization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Absolute measurements have been made of single-electron charge-exchange cross sections of H+, He+, and He2+ in H2O and CO2 in the energy range 0.3-7.5 keV amu(-1). Collisions of this type occur in the interaction of solar wind ions with cometary gases and have been observed by the Giotto spacecraft using the Ion Mass Spectrometer/High Energy Range Spectrometer (IMS/HERS) during a close encounter with comet Halley in 1986. Increases in the He+ ion density, and in the He2+ to H+ density ratio were reported by Shelley et al, and Fuselier et al. and were explained by charge exchange. However, the lack of reliable cross sections for this process made interpretation of the data difficult. New cross sections are presented and discussed in relation to the Giotto observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Karaoke singing is a popular form of entertainment in several parts of the world. Since this genre of performance attracts amateurs, the singing often has artifacts related to scale, tempo, and synchrony. We have developed an approach to correct these artifacts using cross-modal multimedia streams information. We first perform adaptive sampling on the user's rendition and then use the original singer's rendition as well as the video caption highlighting information in order to correct the pitch, tempo and the loudness. A method of analogies has been employed to perform this correction. The basic idea is to manipulate the user's rendition in a manner to make it as similar as possible to the original singing. A pre-processing step of noise removal due to feedback and huffing also helps improve the quality of the user's audio. The results are described in the paper which shows the effectiveness of this multimedia approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using two complementary experimental methods, we have measured partial (mass-resolved) cross-sections for dissociative electron attachment to the molecule trifluoromethyl sulfurpentafluoride (SF5CF3) at the gas temperature T-G = 300 K over a broad range of electron energies (E = 0.001-12 eV). The absolute scale for these cross-sections was obtained with reference to the thermal (T = 300 K) rate coefficient for anion formation (8.0(3) x 10(-8) cm(3) s(-1)). Below 1 eV, SF5- is the dominant product anion and formed through the lowest anion state which cuts the neutral SF5CF3 potential close to the S-C equilibrium distance. The highly resolved laser photoelectron attachment data exhibit a downward Wigner cusp at 86meV, indicating that the nu(4)(alpha(1)) vibrational mode is important for the primary attachment dynamics. Both SF5- and F- anions are formed with similar yields through the first excited resonance located near 3.6eV. Towards higher energies, the anions CF3-, SF4-, and SF3- are also produced. Summation of the partial cross-sections yields a total absolute cross-section for anion formation over the energy range 0.001-12 eV. This is used to calculate the dependence of the rate coefficient for dissociative electron attachment over a broad range of electron temperatures for the fixed gas temperature T-G = 300 K; good agreement is found between the calculated values and those obtained in a drift tube experiment. In addition to the experimental work, semiempirical R-matrix calculations have been Carried out for the energy dependence of the cross-section for SF5- formation. The experimental findings are semi-quantitatively recovered. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conductive ionic liquid -poly(ethylene glycol) (IL-PEG) gels have been prepared by gelation of the hydrophobic ionic liquid 1-hexyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [(C(6)mim] [NTf2]) by the cross-linking reaction of disuccinimidylpropyl PEG monomers with four-arm tetraamine PEG cross-linkers. This is the first time that a crosslinked PEG matrix, such as this, has been used to gel nonaqueous solvents. Initial studies screening other ionic liquids as solvents indicate that the gelation of the ionic liquid is both cation and anion dependent with smaller, coordinating cations disrupting or preventing gel formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Special issue on Sensor Systems for Structural Health Monitoring Abstract—This study addresses the direct calibration of optical fiber strain sensors used for structural monitoring and is carried out in situ. The behavior of fiber-Bragg-grating-based sensor systems when attached to metal bars, in a manner representative of their use as reinforcement bars in structures, was examined and their response calibrated. To ensure the validity of the measurements,this was done using an extensometer with a further calibrationagainst the response of electrical resistance strain gauges, often conventionally used, for comparison. The results show a repeatable calibration generating a suitable geometric factor of extension to strain for these sensors, to enable accurate strain data to be obtained when the fiber-optic sensor system is in use in structural monitoring applications.