983 resultados para Software clones Detection
Resumo:
BACKGROUND AND OBJECTIVES: The determination of the carbon isotope ratio in androgen metabolites has been previously shown to be a reliable, direct method to detect testosterone misuse in the context of antidoping testing. Here, the variability in the 13C/12C ratios in urinary steroids in a widely heterogeneous cohort of professional soccer players residing in different countries (Argentina, Italy, Japan, South Africa, Switzerland and Uganda) is examined. METHODS: Carbon isotope ratios of selected androgens in urine specimens were determined using gas chromatography/combustion/isotope ratio mass spectrometry (GC-C-IRMS). RESULTS: Urinary steroids in Italian and Swiss populations were found to be enriched in 13C relative to other groups, reflecting higher consumption of C3 plants in these two countries. Importantly, detection criteria based on the difference in the carbon isotope ratio of androsterone and pregnanediol for each population were found to be well below the established threshold value for positive cases. CONCLUSIONS: The results obtained with the tested diet groups highlight the importance of adapting the criteria if one wishes to increase the sensitivity of exogenous testosterone detection. In addition, confirmatory tests might be rendered more efficient by combining isotope ratio mass spectrometry with refined interpretation criteria for positivity and subject-based profiling of steroids.
Resumo:
Transmission electon microscopy has been employed for the rapid detection of mycoplasma in sera and cell cultures. High speed centrifugation of sera or low speed centrifugation of cell debris, followed by negative staining of the resuspended pellet, detected mycoplasma contamination more frequently than a culture method followed by direct fluorescence (DAPI), which was used as a control procedure. The appearance of the mycoplasma cell border and content gives some information about particle viability.
Resumo:
Dez clones isolados das cepas Y, CL e MR foram caracterizados segundo infectividade das culturas, curvas de parasitemia, polimorfismo e mortalidade em camundongos C3H isogênicos. Entra os clones das cepas Y e CL foram encontradas diferenças intragrupos bastante significativas. Os clones da cepa MR apresentaram maior homogeneidade. Estes resultados indicam que as cepas do T. cruzi podem apresentar diferentes graus de heterogeneidade. Também sugerem que as condições utilizadas para a manutenção de cepas de T. cruzi podem resultar em vantagens seletivas para algumas subpopulações, podendo uma cepa ser o resultado da interação destas subpopulações (clones) selecionadas após alguns anos de manutenção em laboratório.
Resumo:
The presence of viral antigen in sections from formalin-fixed and paraffin-embedded human tissues was demonstrated by trypsin digestion followed by direct or indirect immunofluorescence. The specimens may be used for retrospective diagnosis. The immunofluorescence technique has to be adapted to the suspected virus infection on the basis of previous histopathology study. Variations of trypsin concentration time and temperature of incubation, expose different viral antigens and have to be previously tested for each unknown system. For measles virus detection in lung a stronger digestion has to be applied as compared to adenovirus or respiratory disease viruses in the same tisue. Flavivirus in liver tissue needs a weaker digestion. The reproducibility of the method makes it useful as a routine technique in diagnosis of virus infection.
Resumo:
Desde 1999 el Consorcio de Bibliotecas Universitarias de Cataluña (CBUC) ha creado una nueva línea de trabajo, junto con el Centro de Supercomputación de Cataluña (CESCA), para promocionar la investigación que se lleva a cabo en Cataluña y al mismo tiempo contribuir al movimiento mundial de depositar la producción académica y de investigación en la red de forma abierta. Este movimiento mundial, que recibe el nombre de Open Access, ha sido puesto en marcha con la finalidad de crear alternativas al paradigma de pagar por tener acceso a la información que se ha elaborado, muy a menudo, con financiación y recursos públicos. Esta nueva línea de trabajo son los depósitos institucionales. En esta comunicación presentamos brevemente el estado actual de los depósitos cooperativos implementados, su contenido (estándares usados, derechos de autor, preservación, etc.) y su continente (programas y tecnología utilizada, protocolos, etc.).
Resumo:
Therapeutic drug monitoring (TDM) aims to optimize treatments by individualizing dosage regimens based on the measurement of blood concentrations. Dosage individualization to maintain concentrations within a target range requires pharmacokinetic and clinical capabilities. Bayesian calculations currently represent the gold standard TDM approach but require computation assistance. In recent decades computer programs have been developed to assist clinicians in this assignment. The aim of this survey was to assess and compare computer tools designed to support TDM clinical activities. The literature and the Internet were searched to identify software. All programs were tested on personal computers. Each program was scored against a standardized grid covering pharmacokinetic relevance, user friendliness, computing aspects, interfacing and storage. A weighting factor was applied to each criterion of the grid to account for its relative importance. To assess the robustness of the software, six representative clinical vignettes were processed through each of them. Altogether, 12 software tools were identified, tested and ranked, representing a comprehensive review of the available software. Numbers of drugs handled by the software vary widely (from two to 180), and eight programs offer users the possibility of adding new drug models based on population pharmacokinetic analyses. Bayesian computation to predict dosage adaptation from blood concentration (a posteriori adjustment) is performed by ten tools, while nine are also able to propose a priori dosage regimens, based only on individual patient covariates such as age, sex and bodyweight. Among those applying Bayesian calculation, MM-USC*PACK© uses the non-parametric approach. The top two programs emerging from this benchmark were MwPharm© and TCIWorks. Most other programs evaluated had good potential while being less sophisticated or less user friendly. Programs vary in complexity and might not fit all healthcare settings. Each software tool must therefore be regarded with respect to the individual needs of hospitals or clinicians. Programs should be easy and fast for routine activities, including for non-experienced users. Computer-assisted TDM is gaining growing interest and should further improve, especially in terms of information system interfacing, user friendliness, data storage capability and report generation.
Resumo:
Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.
Resumo:
We describe a calorimetric assay for detection of voriconazole-resistant Aspergillus fumigatus within 8 h. Among 27 genetically distinct strains, all 21 resistant and all 6 susceptible strains were correctly identified by measurement of fungal heat production in the presence of voriconazole. This proof-of-concept study demonstrates the potential of microcalorimetry for rapid detection of azole resistance in A. fumigatus.
Resumo:
The technique of sentinel lymph node (SLN) dissection is a reliable predictor of metastatic disease in the lymphatic basin draining the primary melanoma. Reverse transcription-polymerase chain reaction (RT-PCR) is emerging as a highly sensitive technique to detect micrometastases in SLNs, but its specificity has been questioned. A prospective SLN study in melanoma patients was undertaken to compare in detail immunopathological versus molecular detection methods. Sentinel lymphadenectomy was performed on 57 patients, with a total of 71 SLNs analysed. SLNs were cut in slices, which were alternatively subjected to parallel multimarker analysis by microscopy (haematoxylin and eosin and immunohistochemistry for HMB-45, S100, tyrosinase and Melan-A/MART-1) and RT-PCR (for tyrosinase and Melan-A/MART-1). Metastases were detected by both methods in 23% of the SLNs (28% of the patients). The combined use of Melan-A/MART-1 and tyrosinase amplification increased the sensitivity of PCR detection of microscopically proven micrometastases. Of the 55 immunopathologically negative SLNs, 25 were found to be positive on RT-PCR. Notably, eight of these SLNs contained naevi, all of which were positive for tyrosinase and/or Melan-A/MART-1, as detected at both mRNA and protein level. The remaining 41% of the SLNs were negative on both immunohistochemistry and RT-PCR. Analysis of a series of adjacent non-SLNs by RT-PCR confirmed the concept of orderly progression of metastasis. Clinical follow-up showed disease recurrence in 12% of the RT-PCR-positive immunopathology-negative SLNs, indicating that even an extensive immunohistochemical analysis may underestimate the presence of micrometastases. However, molecular analyses, albeit more sensitive, need to be further improved in order to attain acceptable specificity before they can be applied diagnostically.
Resumo:
This paper presents the evaluation of an enzyme immunoassay in which Mayaro virus-infected cultured cells ara used as antigen (EIA-ICC) and an IgM antibody capture ELISA (MAC-ELISA) for Mayaro serologic diagnosis using 114 human sera obtained during a Mayaro outbreak occurred in Bolivia, in 1987. Results were compared with those obtained by haemagglutination-inhibition test (HAI). MAC-ELISA was the most sensitive technique for anti-Mayaro IgM detection. MAC-ELISA was twice sensitive as IgM EIA-ICC. The data shows that MAC-ELISA is a practical and valid technique for diagnosis of recent mayaro infection. IgG-ICC showed hight sensitivity and high specificity compared to HAI. The combination of anti-Mayaro IgG and IgM EIA-ICC results presented the highest sensitivity of the study. Anti-Mayaro IgG and IgM simultaneous detection by ELISA-ICC can be used for recent infection diagnosis (in spite of a less sensitive IgM detection than by MAC-ELISA), for surveillance and sero-epidemiologic studies, and for studies of IgG and IgM responses to Mayaro infection.