971 resultados para Silicon detectors, transient current technique (TCT), TCAD, ATLAS, ATHENA, SILAVACO, MixedMode


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the fabrication of planar sub-micron gratings in silicon with a period of 720 nm using a modified Michelson interferometer and femtosecond laser radiation. The gratings consist of alternated stripes of laser ablated and unmodified material. Ablated stripes are bordered by parallel ridges which protrude above the unmodified material. In the regions where ridges are formed, the laser radiation intensity is not sufficient to cause ablation. Nevertheless, melting and a significant temperature increase are expected, and ridges may be formed due to expansion of silicon during resolidification or silicon oxidation. These conclusions are consistent with the evolution of the stripes morphology as a function of the distance from the center of the grating. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present results on the use of a semiconductor heterostructure based on a-SiC:H as a wavelength-division demultiplexer for the visible light spectrum. The proposed device is composed of two stacked p-i-n photodiodes with intrinsic absorber regions adjusted to short and long wavelength absorption and carrier collection. An optoelectronic characterisation of the device was performed in the visible spectrum. Demonstration of the device functionality for WDM applications was done with three different input channels covering the long, the medium and the short wavelengths in the visible range. The recovery of the input channels is explained using the photocurrent spectral dependence on the applied voltage. An electrical model of the WDM device is proposed and supported by the solution of the respective circuit equations. Short range optical communications constitute the major application field however other applications are foreseen. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of room impulse response (RIR) when there are high background noise levels frequently means one must deal with very low signal-to-noise ratios (SNR). if such is the case, the measurement might yield unreliable results, even when synchronous averaging techniques are used. Furthermore, if there are non-linearities in the apparatus or system time variances, the final SNR can be severely degraded. The test signals used in RIR measurement are often disturbed by non-stationary ambient noise components. A novel approach based on the energy analysis of ambient noise - both in the time and in frequency - was considered. A modified maximum length sequence (MLS) measurement technique. referred to herein as the hybrid MLS technique, was developed for use in room acoustics. The technique consists of reducing the noise energy of the captured sequences before applying the averaging technique in order to improve the overall SNRs and frequency response accuracy. Experiments were conducted under real conditions with different types of underlying ambient noises. Results are shown and discussed. Advantages and disadvantages of the hybrid MLS technique over standard MLS technique are evaluated and discussed. Our findings show that the new technique leads to a significant increase in the overall SNR. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nos dias de hoje é necessário criar hábitos de vida mais saudáveis que contribuam para o bem-estar da população. Adoptar medidas e práticas de modo regular e disciplinado, pode diminuir o risco do aparecimento de determinadas doenças, como a obesidade, as doenças cardiovasculares, a hipertensão, a diabetes, alguns tipos de cancro e tantas outras. É também importante salientar que, uma alimentação cuidada dá saúde e aumenta a esperança média de vida. Em Portugal, nos últimos anos, os costumes alimentares da população têm vindo a alterar-se significativamente. As refeições caseiras confeccionadas com produtos frescos dão lugar à designada “cultura do fast food”. Em contrapartida, os consumidores são cada vez mais exigentes, estando em permanente alerta no que se refere ao estado dos alimentos. A rotulagem de um produto, para além da função publicitária, tem vindo a ser objecto de legislação específica de forma a fornecer informação simples e clara, correspondente à composição, qualidade, quantidade, validade ou outras características do produto. Estas informações devem ser acessíveis a qualquer tipo de público, com mais ou menos formação e de qualquer estrato social. A qualidade e segurança dos produtos deve basear-se na garantia de que todos os ingredientes, materiais de embalagem e processos produtivos são adequados à produção de produtos seguros, saudáveis e saborosos. A Silliker Portugal, S.A. é uma empresa independente de prestação de serviços para o sector agro-alimentar, líder mundial na prestação de serviços para a melhoria da qualidade e segurança alimentar. A Silliker dedica-se a ajudar as empresas a encontrar soluções para os desafios actuais do sector, oferecendo uma ampla gama de serviços, onde se inclui o serviço de análises microbiológicas, químicas e sensorial; consultadoria em segurança alimentar e desenvolvimento; auditorias; rotulagem e legislação. A actualização permanente de procedimentos na procura de uma melhoria contínua é um dos objectivos da empresa. Para responder a um dos desafios colocados à Silliker, surgiu este trabalho, que consistiu no desenvolvimento de um novo método para determinação de ácidos gordos e da gordura total em diferentes tipos de alimentos e comparação dos resultados, com os obtidos com o método analítico até então adoptado. Se a gordura é um elemento de grande importância na alimentação, devido às suas propriedades nutricionais e organoléticas, recentemente, os investigadores têm focado a sua atenção nos mais diversos ácidos gordos (saturados, monoinsaturados e polinsaturados), em particular nos ácidos gordos essenciais e nos isómeros do ácido linoleico conjugado (CLA), uma mistura de isómeros posicionais e geométricos do ácido linoleico com actividade biológica importante. A técnica usada nas determinações foi a cromatografia gasosa com ionização de chama, GC-FID, tendo as amostras sido previamente tratadas e extraídas de acordo com o tipo de matriz. A metodologia analítica desenvolvida permitiu a correcta avaliação do perfil em ácidos gordos, tendo-se para isso usado uma mistura de 37 ésteres metílicos, em que o ácido gordo C13:0 foi usado como padrão interno. A identificação baseou-se nos tempos de retenção de cada ácido gordo da mistura e para a quantificação usaram-se os factores de resposta. A validação do método implementado foi baseada nos resultados obtidos no estudo de três matrizes relativas a materiais certificados pela BIPEA (Bureau Interprofessionnel des Etudes Analytiques), para o que foram efectuadas doze réplicas de cada matriz. Para cada réplica efectuada foi calculado o teor de matéria gorda, sendo posteriormente o resultado comparado com o emitido pela entidade certificada. Após análise de cada constituinte foi também possível calcular o teor em ácidos gordos saturados, monoinsaturados e polinsaturados. A determinação do perfil em ácidos gordos dos materiais certificados foi aceitável atendendo aos valores obtidos, os quais se encontravam no intervalo de valores admissíveis indicados nos relatórios. A quantificação da matéria gorda no que se refere à matriz de “Paté à Tartinier” apresentou um z-score de 4,3, o que de acordo com as exigências internas da Silliker, não é válido. Para as outras duas matrizes (“Mélange Nutritif” e “Plat cuisiné à base de viande”) os valores de z-score foram, respectivamente, 0,7 e -1,0, o que permite concluir a validade do método. Para que o método possa vir a ser adoptado como método alternativo é necessário um estudo mais alargado relativamente a amostras com diferentes composições. O método foi aplicado na análise de amostras de fiambre, leite gordo, queijo, ovo com ómega 3, amendoim e óleo de girassol, e os resultados foram comparados com os obtidos pelo método até então adoptado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Electrocardiogram (ECG) monitoring system deals with several challenges related with noise sources. The main goal of this text was the study of Adaptive Signal Processing Algorithms for ECG noise reduction when applied to real signals. This document presents an adaptive ltering technique based on Least Mean Square (LMS) algorithm to remove the artefacts caused by electromyography (EMG) and power line noise into ECG signal. For this experiments it was used real noise signals, mainly to observe the di erence between real noise and simulated noise sources. It was obtained very good results due to the ability of noise removing that can be reached with this technique. A recolha de sinais electrocardiogr a cos (ECG) sofre de diversos problemas relacionados com ru dos. O objectivo deste trabalho foi o estudo de algoritmos adaptativos para processamento digital de sinal, para redu c~ao de ru do em sinais ECG reais. Este texto apresenta uma t ecnica de redu c~ao de ru do baseada no algoritmo Least Mean Square (LMS) para remo c~ao de ru dos causados quer pela actividade muscular (EMG) quer por ru dos causados pela rede de energia el ectrica. Para as experiencias foram utilizados ru dos reais, principalmente para aferir a diferen ca de performance do algoritmo entre os sinais reais e os simulados. Foram conseguidos bons resultados, essencialmente devido as excelentes caracter sticas que esta t ecnica tem para remover ru dos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Ciências Biomédicas, 3 de Fevereiro de 2016, Universidade dos Açores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório Final de Estágio apresentado à Escola Superior de Dança, com vista à obtenção do grau de Mestre em Ensino de Dança.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório Final de Estágio apresentado à Escola Superior de Dança, com vista à obtenção do grau de Mestre em Ensino de Dança

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conferência: 2nd Experiment at International Conference (Exp at)- Univ Coimbra, Coimbra, Portugal - Sep 18-20, 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To verify the results of a diaphragmatic breathing technique (DBT) on diaphragmatic range of motion in healthy subjects. Methods - A total of 51 healthy subjects (10 male; 41 female), mean age 20 years old and a body mass index (BMI) ranging from 15.6 to 34.9 kg/m2, were enrolled in this study. Diaphragmatic range of motion was assessed by M-mode ultrasound imaging. Measurements were made before and after the DBT implementation in a standard protocol, based on 3 seconds of inspiration starting from a maximum expiration. Differences between assessments were analyzed by descriptive statistics and t-test (p < 0.05). Results - Mean value range of motion before DBT was 55.3 ± 13.4 mm and after DBT was 63.8 ± 13.2 mm showing a significant improvement of 8.5 ± 14.7 mm (p < 0.001). A strong correlation between the slope and the range of motion was found (r = 0.71, p < 0.001). Conclusions - Based on ultrasound measurements, it has been proved that DBT really contributes to a higher diaphragmatic range of motion. Future studies are needed in order to understand the influence of protocol parameters (e.g. inspiration time). Clinical implications - In the contest of evidence-based practice in physiotherapy, it has been showed by objective measurements that DBT improves the diaphragm range of motion, translating into a more efficient ventilatory function and thus can be used in clinical setting. To our knowledge this is the first study to assess the effects of DBT on range of motion of diaphragm muscle with ultrasound imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The globalization is a process of economical, social, cultural and political integration motivated by the needs generated by a consumption-orientated society and a set of factors that have led to its development, such as reducing transport costs, the technological advancement and the development of communication networks. However, the phenomenon of globalization has been accompanied by increasing levels of insecurity as a result of various types of threats and transnational crimes that the International Community seeks to control and minimize. Throughout this work, we examined how the globalization process has been developing and how nations are able to maintain security levels consistent with their economical status and social development, without disturbing the normal course of organizations’ economical activity and the well-being of people. From the investigation developed we concluded that, besides the confirmation that economic integration and the opening of markets have influence on internal consumption, market globalization and migrations have been causing modifications in the consumption habits. We also concluded that the security measures implemented by States or by the International Community affect international trade, but do not imply disproportionate costs or significant delays in transactions. Likewise, we concluded that the control measures implemented in international trade are sufficient to ensure the safety of the people and nations, enabling us to confirm two of the three conjectures raised in this study.