996 resultados para SODIUM EXCRETION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sodium azumolene is a drug designed to fight Malignant Hyperthermia (MH), which is characterized by genetic predisposition and triggered by the use of inhalational anesthetics. This drug is shown as a water-soluble analogue of dantrolene sodium, 30-folds more water soluble, which gives advantages for its emergency use. To our knowledge there is no analytical method for sodium zaumolene raw material or dosage form published so far. The objective of the present investigation was to develop and validate analytical methods to achieve sodium azumolene chemical identification and quantification. The sodium azumolene was characterized regarding its thermal behavior, by differential thermal analysis and thermogravimetric analysis; Visible, UV and infrared absorption. To accurately assess the sodium Azumolene content three different analytical methods (visible and UV spectrophotometry and high performance liquid chromatography) were developed and validated. All methods showed to be linear, accurate, precise and reliable. Azumolene has shown to be equipotent to dantrolene in the treatment and prevention of an MH crisis and the great advantage compared to dantrolene is better water solubility. This study has characterized the sodium azumolene and presents new analytical methods which have not been reported so far.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase high performance liquid chromatography method was validated for the determination of cefazolin sodium in lyophilized powder for solution for injection to be applied for quality control in pharmaceutical industry. The liquid chromatography method was conducted on a Zorbax Eclipse Plus C18 column (250 x 4.6 mm, 5 μm), maintained at room temperature. The mobile phase consisted of purified water: acetonitrile (60: 40 v/v), adjusted to pH 8 with triethylamine. The flow rate was of 0.5 mL min-1 and effluents were monitored at 270 nm. The retention time for cefazolin sodium was 3.6 min. The method proved to be linear (r2 =0.9999) over the concentration range of 30-80 µg mL-1. The selectivity of the method was proven through degradation studies. The method demonstrated satisfactory results for precision, accuracy, limits of detection and quantitation. The robustness of this method was evaluated using the Plackett–Burman fractional factorial experimental design with a matrix of 15 experiments and the statistical treatment proposed by Youden and Steiner. Finally, the proposed method could be also an advantageous option for the analysis of cefazolin sodium, contributing to improve the quality control and to assure the therapeutic efficacy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antimicrobials have unquestionable importance in the control of many diseases; however the constant concern with evolution of resistant microorganisms is increasing. The ertapenem sodium is a β-lactam antibiotic of the carbapenem class, which it has a broader activity spectrum than most other β-lactam antimicrobials, and is more resistant to the enzyme β-lactamase, which is the main mechanism of resistance of many bacteria. The progress of microbial resistance to existing antibiotics is alarming. Thus we need to preserve antimicrobials that still have activity against these pathogens. In this context, the quality control has a key role to ensure the correct dosage, by contributing preventively to minimize the development of resistant microorganisms. Study of the physicochemical characteristics of the drug and the quantification of the content of active substance are of fundamental importance for the pharmaceutical industry to ensure the quality of the product sold. This work presents a literature survey of existing methods for ertapenem sodium quantification which was performed. Ertapenem sodium can be analyzed by many types of assays; however the HPLC is the most used method. This review will examine the published analytical methods reported for determination of ertapenem sodium, in biological fluids and formulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flucloxacillin sodium (FLU) is a semi-synthetic penicillin active against many gram-positive bacteria such as streptococci and penicilinase-producing staphylococci, including methicillin-susceptible S. aureus. This study describes the development and validation of a microbiological assay, applying the diffusion agar method for the determination of FLU, as well as the evaluation of the ability of the method in determining the stability of FLU in capsules against acidic and basic hydrolysis, photolytic and oxidative degradations, using S. aureus ATCC 25923 as micro-organism test and 3 x 3 parallel line assay design (three doses of the standard and three doses of the sample in each plate), with six plates for each assay, according to the Brazilian Pharmacopoeia. The validation method showed good results including linearity, precision, accuracy, robustness and selectivity. The assay is based on the inhibitory effect of FLU using Staphylococcus aureus ATCC 25923. The results of the assay were treated by analysis of variance (ANOVA) and were found to be linear (r = 0.9997) in the range from 1.5 to 6.0 μg/mL, precise (repeatability: R.S.D. = 1.63 and intermediate precision: R.S.D. = 1.64) and accurate (98.96%). FLU solution (from the capsules) exposed to direct UVC light (254 nm), alkaline and acid hydrolysis and hydrogen peroxide causing oxidation were used to evaluate the specificity of the bioassay. Comparison of bioassay and liquid chromatography by ANOVA showed no difference between methodologies. The results demonstrated the validity of the proposed bioassay, which is a simple and useful alternative methodology for FLU determination in routine quality control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New and improved strategies are needed for managing overabundant blackbird (Icteridae spp.) populations in some areas of the United States. From 2004 to 2007, we evaluated sodium lauryl sulfate (SLS) as a wetting agent during controlled outdoor cage and flight pen tests in Colorado and small-scale field tests at urban blackbird roosts in Missouri. In the outdoor cage tests (ambient temperature -5 to 2° C), mortality of male red-winged blackbirds (Agelaius phoeniceus) sprayed with 1, 2, and 5 ml of SLS on the back feathers only, on the breast feathers only, or on both breast and back feathers ranged from 25% to 100%. A SLS spray on male red-winged blackbirds at 2° C ambient temperature with 1 ml of SLS sprayed on breast feathers and back feathers resulted in 90% mortality in less than 60 minutes. In a flight pen test (-12 to -5° C ambient temperature ), SLS sprayed at 20 l per 3,400 l of water with a single ground-based sprinkler-head system over 35 male red-winged blackbirds roosting in cedar trees (Juniperus virginiana) resulted in 53% mortality. There was no mortality in the control group exposed to the same treatment without the SLS. Small-scale field tests conducted in Missouri at 6 sites with a single ground-based sprinkler-head spray system and at 2 sites with 4 sprinkler-head spray systems resulted in mortality that ranged from 0 to 4,750 and 4,500 to 15,000 blackbirds and starlings, respectively. Spray operations lasted from 28 to 208 minutes. Each spray covered about 200 m2 . At all sites, mortality of blackbirds sprayed with the SLS occurred as soon as 30 minutes post-SLS application. Mortality at two sites where pump problems precluded completing the spray ranged from 0 to 800 birds. Air leaving the system as the system was activated caused birds to flush from the roost trees. Poor water quality and pump durability were problems at some sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dry mass (DM) and total ammonia-N (TAN) excretion were determined in embryos, larvae (ZI-ZIX, Z = zoea ), and postlarvae (PL) at 1, 7, and 14 d after metamorphosis (PL1, PL7, and PL14) of Macrobrachium amazonicum. Animals in postmolt-intermolt (A-C) stages were sorted according to their developmental stages, and placed into incubation chambers (similar to 30 mL) for 2 h to quantify TAN excretion. After this period, analyses were carried out using Koroleff`s method for TAN determination. Individual TAN excretion generally increased throughout ontogenetic development and varied from 0.0090 +/- 0.0039 mu g TAN/individual/h in embryo to 1.041 +/- 0.249 mu g TAN/individual/h in PL14. There was no significant difference between embryo-ZIV and ZV-ZIX (P > 0.05), whereas PL1, PL7, and PL14 differed (P < 0.05) from each other. Higher increments in individual ammonia-N excretion were observed between ZIV-ZV, PL1-PL7, and PL7-PL14. Mass-specific excretion rates presented two groups, embryo-ZII (P > 0.05) and ZIII-PL14 (P > 0.05). The lowest value was found in embryo (0.17 +/- 0.07 mu g TAN/mg DM/h) and the maximum values in ZV and PL1 (0.65 +/- 0.25 and 0.64 +/- 0.27 mu g TAN/mg DM/h, respectively). Results indicate that metabolic rate is proportional to the body mass in M. amazonicum, during early life stages. Variations in ammonia excretion during this phase may be associated mainly with body size. Data obtained in the present study may be useful in developing and optimizing rearing techniques of M. amazonicum, such as the proportions between biofilter and rearing tank size, and stocking density in culture tanks or in transport bags.