979 resultados para Multi-standard receiver
Resumo:
A procedure for the dynamic generation of 1,6-hexamethylene diisocyanate (HDI) aerosol atmospheres of 70 micrograms m-3 (0.01 ppm) to 1.75 mg m-3 (0.25 ppm), based on the precise control of the evaporation of pure liquid HDI and subsequent dilution with air, was developed. The apparatus consisted of a home-made glass nebulizer coupled with a separation stage to exclude non-respirable droplets (greater than 10 microns). The aerosol concentrations were achieved by passing air through the nebulizer at 1.5-4.5 l. min-1 to generate dynamically 0.01-0.25 ppm of diisocyanate in an experimental chamber of 8.55 m3. The distribution of the liquid aerosol was established with an optical counter and the diisocyanate concentration was determined from samples collected in impingers by a high-pressure liquid chromatographic method. The atmospheres generated were suitable for the evaluation both of sampling procedures full scale, and of analytical methods: at 140 micrograms m-3 (0.02 ppm) they remained stable for 15-min provocation tests in clinical asthma, as verified by breath-zone sampling of exposed patients.
Resumo:
The aim of this study was to compare the diagnostic efficiency of plain film and spiral CT examinations with 3D reconstructions of 42 tibial plateau fractures and to assess the accuracy of these two techniques in the pre-operative surgical plan in 22 cases. Forty-two tibial plateau fractures were examined with plain film (anteroposterior, lateral, two obliques) and spiral CT with surface-shaded-display 3D reconstructions. The Swiss AO-ASIF classification system of bone fracture from Muller was used. In 22 cases the surgical plans and the sequence of reconstruction of the fragments were prospectively determined with both techniques, successively, and then correlated with the surgical reports and post-operative plain film. The fractures were underestimated with plain film in 18 of 42 cases (43%). Due to the spiral CT 3D reconstructions, and precise pre-operative information, the surgical plans based on plain film were modified and adjusted in 13 cases among 22 (59%). Spiral CT 3D reconstructions give a better and more accurate demonstration of the tibial plateau fracture and allows a more precise pre-operative surgical plan.
Resumo:
BACKGROUND: Greenstick fractures suffered during growth have a high risk for refracture and posttraumatic deformity, particularly at the forearm diaphysis. The use of a preemptive completion of the fracture by manipulation of the concave cortex is controversial and data supporting this approach are few. AIM: Aim of this study was to determine the factors which predispose to refracture and deformities, and to define therapeutic strategies. METHODS: We prospectively gathered clinical and radiographic data over a period of one year on greenstick fractures of the middle third of the forearm in children as part of a multi-centre study. Endpoint was a follow-up visit at one year. Radiographic deformity, state of consolidation at resumption of physical activities and refracture rate were analysed statistically (ANOVA, Student's t-test and Pearson's chi-square test) with regard to patient age, gender, fracture type, therapy and time in plaster. RESULTS: We collected the data of 103 patients (63 boys, 40 girls), average age 6.6 years (1.3-14.5 years), the vast majority of whom had a combined greenstick fracture of the radius and ulna. 6.7% of the patients sustained a refracture within 49 days (29-76) after plaster removal. They were significantly older (p=0.017) with a significantly higher incidence of manual completion of the fracture with radiographic signs of partial consolidation (p=0.025). Residual deformities were significantly smaller after completion of the fracture compared to reduction without completion (p=0.019) or plaster fixation alone (p<0.005). CONCLUSIONS: Completion of a greenstick fracture does not prevent refracture. Nevertheless, it diminishes the extent of secondary deformities in cases where the primary angulation exceeds the remodelling capacity. Prevention of refracture should include a routine radiographic follow-up 4-6 weeks after injury with continuation of plaster fixation in cases of partial consolidation.
Resumo:
Purpose:To describe the indications, the surgical procedure and the clinical outcome of MLAM in the treatment of non traumatic corneal perforations and descemetoceles . Methods:A prospective, non comparative, interventional case series of eight consecutive patients (mean age 59 years old, 6 men and 2 women) with non traumatic corneal perforations or descemetoceles.The surgery consisted in a MLAM transplantation of a cryopreservated human amniotic membrane. The series included: three active herpetic keratitis, one rosacea, one perforation of an hydrops, one cicatricial pemphigoid, one perforation after an abcess in a corneal graft and one perforation after protonbeamtherapy. The clinical outcome included: the follow-up, the integrity of the eye, corneal epithelialization, inflammation and neovascularization, and the integration of the MLAM. Stromal thickness was followed precisely with the slit lamp. A corneal graft was performed at one patient after the MLAM, allowing microscopic investigation of the removed MLAM integrated in the cornea. Results:The mean follow-up was 8.78 months (range 3.57 to 30.17). Amniotic membrane transplantation was successful and reduced inflammation in 7 patients out of 8 ,after one procedure.One patient who presented a large herpetic keratitis epithelial defect with corneal anaesthesia had his MLAM dissolved after two weeks with an aqueous leakage. Epithelium healed within 3 weeks above 7 MLAM and remained stable at 3 months in 7 out of 8 patients. MLAM opacification gradually disappeared over a few months, however, stromal layers filling in the corneal perforations or above the descemetoceles remained stable. Conclusions:MLAM transplantation is a safe, effective and useful technique to cure non traumatic corneal perforations and descemetoceles. It can be performed in emergency despite the presence of an active inflammation or infection. By facilitating epithelialization, reducing inflammation and neovascularization, it allows corneal surface reconstruction in patients with persistent epithelial defects and corneal melting that usually ends in a perforation. For full visual rehabilitation, a delayed penetrating keratoplasty is required.
Resumo:
Allele frequencies and forensically relevant population statistics of 16 STR loci, including the new European Standard Set (ESS) loci, were estimated from 668 unrelated individuals of Caucasian appearance living in different parts of Switzerland. The samples were amplified with a combination of the following three kits: AmpFlSTR® NGM SElect?, PowerPlex® ESI17 and PowerPlex® ESX 17. All loci were highly polymorphic and no significant departure from Hardy-Weinberg equilibrium and linkage equilibrium was detected after correction for sampling.
Resumo:
Purpose: To examine the relationship of functional measurements with structural measures. Methods: 146 eyes of 83 test subjects underwent Heidelberg Retinal Tomography (HRTIII) (disc area<2.43, mphsd<40), and perimetry testing with Octopus (SAP; Dynamic), Pulsar (PP; TOP) and Moorfields MDT (ESTA). Glaucoma was defined as progressive structural or functional loss (20 eyes). Perimetry test points were grouped into 6 sectors based on the estimated optic nerve head angle into which the associated nerve fiber bundle enters (Garway-Heath map). Perimetry summary measures (PSM) (MD SAP/ MD PP/ PTD MDT) were calculated from the average total deviation of each measured threshold from the normal for each sector. We calculated the 95% significance level of the sectorial PSM from the respective normative data. We calculated the percentage agreement with group1 (G1), healthy on HRT and within normal perimetric limits, and group 2 (G2), abnormal on HRT and outside normal perimetric limits. We also examined the relationship of PSM and rim area (RA) in those sectors classified as abnormal by MRA (Moorfields Regression Analysis) of HRT. Results: The mean age was 65 (range= [37, 89]). The global sensitivity versus specificity of each instrument in detecting glaucomatous eyes was: MDT 80% vs. 88%, SAP 80% vs. 80%, PP 70% vs. 89% and HRT 80% vs. 79%. Highest percentage agreement of HRT (respectively G1, G2, sector) with PSM were MDT (89%, 57%, nasal superior), SAP (83%, 74%, temporal superior), PP (74%, 63%, nasal superior). Globally percentage agreement (respectively G1, G2) was MDT (92%, 28%), SAP (87%, 40%) and PP (77%, 49%). Linear regression showed there was no significant trend globally associating RA and PSM. However, sectorally the supero-nasal sector had a statistically significant (p<0.001) trend with each instrument, the associated r2 coefficients are (MDT 0.38 SAP 0.56 and PP 0.39). Conclusions: There were no significant differences in global sensitivity or specificity between instruments. Structure-function relationships varied significantly between instruments and were consistently strongest supero-nasally. Further studies are required to investigate these relationships in detail.
Resumo:
INTRODUCTION: Quitting smoking is associated with weight gain, which may threaten motivation to engage or sustain a quit attempt. The pattern of weight gained by smokers treated according to smoking cessation guidelines has been poorly described. We aimed to determine the weight gained after smoking cessation and its predictors, by smokers receiving individual counseling and nicotine replacement therapies for smoking cessation. METHODS: We performed an ancillary analysis of a randomized controlled trial assessing moderate physical activity as an aid for smoking cessation in addition to standard treatment in sedentary adult smokers. We used mixed longitudinal models to describe the evolution of weight over time, thus allowing us to take every participant into account. We also fitted a model to assess the effect of smoking status and reported use of nicotine replacement therapy at each time point. We adjusted for intervention group, sex, age, nicotine dependence, and education. RESULTS: In the whole cohort, weight increased in the first 3 months, and stabilized afterwards. Mean 1-year weight gain was 3.3kg for women and 3.9kg for men (p = .002). Higher nicotine dependence and male sex were associated with more weight gained during abstinence. Age over median was associated with continuing weight gain during relapse. There was a nonsignificant trend toward slower weight gain with use of nicotine replacement therapies. CONCLUSION: Sedentary smokers receiving a standard smoking cessation intervention experience a moderate weight gain, limited to the first 3 months. Older age, male sex, and higher nicotine dependence are predictors of weight gain.
Resumo:
OBJECTIVE Evaluate and correlate individual, work-related and organizational factors that influence adherence to standard precautions among nursing professionals of psychiatric hospitals in São Paulo. METHOD An exploratory cross-sectional study conducted with 35 nursing professionals, using the assessment tool for adherence to standard precautions through the Likert scale, ranging from 1 to 5. RESULTS Knowledge of the precautions received a high score (4.69); adherence received (3.86) and obstacles (3.78), while intermediaries and the scales of organizational factors received low scores (2.61). There was a strong correlation between the magnitude adherence scale and the personal protective equipment availability (r = 0.643; p = 0.000). The training scale for prevention of HIV exposure (p = 0.007) was statistically different between the nurses and nursing assistants. CONCLUSION The organizational factors negatively contributed to adherence to standard precautions, indicating that psychiatric institutions lack safe working conditions, ongoing training and management actions to control infections.
Resumo:
Secretory IgA (SIgA) plays an important role in the protection and homeostatic regulation of intestinal, respiratory, and urogenital mucosal epithelia separating the outside environment from the inside of the body. This primary function of SIgA is referred to as immune exclusion, a process that limits the access of numerous microorganisms and mucosal antigens to these thin and vulnerable mucosal barriers. SIgA has been shown to be involved in avoiding opportunistic pathogens to enter and disseminate in the systemic compartment, as well as tightly controlling the necessary symbiotic relationship existing between commensals and the host. Clearance by peristalsis appears thus as one of the numerous mechanisms whereby SIgA fulfills its function at mucosal surfaces. Sampling of antigen-SIgA complexes by microfold (M) cells, intimate contact occurring with Peyer's patch dendritic cells (DC), down-regulation of inflammatory processes, modulation of epithelial, and DC responsiveness are some of the recently identified processes to which the contribution of SIgA has been underscored. This review aims at presenting, with emphasis at the biochemical level, how the molecular complexity of SIgA can serve these multiple and non-redundant modes of action.
Resumo:
In order to investigate the spatial and temporal variability (daily, seasonal and inter-annual) of CO2 and O2 air-sea fluxes and their underlying processes, a dense network of observations is required. For this purpose, the Cape Verde Ocean Observatory (CVOO) provides a unique infrastructure. Information thus obtained also links biological productivity and atmospheric composition. To expand these capabilities, a novel “virtual mooring” approach for high resolution measurements, based on a modified NEMO profiling float, is pursued. This Profiling Float was equipped with O2 and pCO2 sensors for the first time, in order to collect daily depth profiles (0-200 m) in the vicinity of the ocean site. Data access and remote control is provided through Iridium satellite telemetry. Recalibrations and redeployments are carried out every 1-3 month. First, we present the new developed instrument and the innovative in situ and real-time approach behind. Second, we show the inter-disciplinary scientific objectives which will benefit from this approach as a result of the intensive partnership between IFM-GEOMAR and INDP during the last years.
Resumo:
The delivery kinetics of growth factors has been suggested to play an important role in the regeneration of peripheral nerves following axotomy. In this context, we designed a nerve conduit (NC) with adjustable release kinetics of nerve growth factor (NGF). A multi-ply system was designed where NC consisting of a polyelectrolyte alginate/chitosan complex was coated with layers of poly(lactide-co-glycolide) (PLGA) to control the release of embedded NGF. Prior to assessing the in vitro NGF release from NC, various release test media, with and without stabilizers for NGF, were evaluated to ensure adequate quantification of NGF by ELISA. Citrate (pH 5.0) and acetate (pH 5.5) buffered saline solutions containing 0.05% Tween 20 yielded the most reliable results for ELISA active NGF. The in vitro release experiments revealed that the best results in terms of reproducibility and release control were achieved when the NGF was embedded between two PLGA layers and the ends of the NC tightly sealed by the PLGA coatings. The release kinetics could be efficiently adjusted by accommodating NGF at different radial locations within the NC. A sustained release of bioactive NGF in the low nanogram per day range was obtained for at least 15days. In conclusion, the developed multi-ply NGF loaded NC is considered a suitable candidate for future implantation studies to gain insight into the relationship between local growth factor availability and nerve regeneration.
Resumo:
This paper explores the effects of a standard influencing care choice. Firm(s) may increase the probability of offering safe products by incurring a cost. Under duopoly, they compete either in prices or in quantities. Under perfect information about safety for consumers, the selected standard that corrects a safety underinvestment is always compatible with competition. Safety over investment only emerges under competition in quantities and relatively low values of the cost. Under imperfect information about safety for consumers, the standard leads to a monopoly situation. However, for relatively large values of the cost, a standard cannot impede the market failure coming from the lack of information.
Resumo:
Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.