997 resultados para Medical microscopy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The term endothelial progenitor cells (EPCs) is currently used to refer to cell populations which are quite dissimilar in terms of biological properties. This study provides a detailed molecular fingerprint for two EPC subtypes: early EPCs (eEPCs) and outgrowth endothelial cells (OECs). METHODS: Human blood-derived eEPCs and OECs were characterised by using genome-wide transcriptional profiling, 2D protein electrophoresis, and electron microscopy. Comparative analysis at the transcript and protein level included monocytes and mature endothelial cells as reference cell types. RESULTS: Our data show that eEPCs and OECs have strikingly different gene expression signatures. Many highly expressed transcripts in eEPCs are haematopoietic specific (RUNX1, WAS, LYN) with links to immunity and inflammation (TLRs, CD14, HLAs), whereas many transcripts involved in vascular development and angiogenesis-related signalling pathways (Tie2, eNOS, Ephrins) are highly expressed in OECs. Comparative analysis with monocytes and mature endothelial cells clusters eEPCs with monocytes, while OECs segment with endothelial cells. Similarly, proteomic analysis revealed that 90% of spots identified by 2-D gel analysis are common between OECs and endothelial cells while eEPCs share 77% with monocytes. In line with the expression pattern of caveolins and cadherins identified by microarray analysis, ultrastructural evaluation highlighted the presence of caveolae and adherens junctions only in OECs. CONCLUSIONS: This study provides evidence that eEPCs are haematopoietic cells with a molecular phenotype linked to monocytes; whereas OECs exhibit commitment to the endothelial lineage. These findings indicate that OECs might be an attractive cell candidate for inducing therapeutic angiogenesis, while eEPC should be used with caution because of their monocytic nature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This Student Selected Component (SSC) was designed to equip United Kingdom (UK) medical students to engage in whole-person care. The aim was to explore students' reactions to experiences provided, and consider potential benefits for future clinical practice.

Methods: The SSC was delivered in the workplace. Active learning was encouraged through facilitated discussion with and observation of clinicians, the palliative team, counselling services, hospital chaplaincy and healing ministries; sharing of medical histories by patients; and training in therapeutic communication. Assessment involved reflective journals, literature appraisal, and role-play simulation of the doctor-patient consultation. Module impact was evaluated by analysis of student coursework and a questionnaire.

Results: Students agreed that the content was stimulating, relevant, and enjoyable and that learning outcomes were achieved. They reported greater awareness of the benefit of clinicians engaging in care of the "whole person" rather than "the disease." Contributions of other professions to the healing process were acknowledged, and students felt better equipped for discussion of spiritual issues with patients. Many identified examples of activities which could be incorporated into core teaching to benefit all medical students.

Conclusion: The SSC provided relevant active learning opportunities for medical students to receive training in a whole-person approach to patient care.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicone elastomer systems have been shown to offer potential for the fabrication of medical devices and sustained release drug delivery devices comprising low molecular weight drugs and protein therapeutics. For drug delivery systems in particular, there is often no clear rationale for selection of the silicone elastomer grade, particularly in respect of optimizing the manufacturing conditions to ensure thermal stability of the active agent and short cycle times. In this study, the cure characteristics of a range of addition-cure and condensation-cure, low-consistency, implant-grade silicone elastomers, either as supplied or loaded with the model protein bovine serum albumin (BSA) and the model hydrophilic excipient glycine, were investigated using oscillatory rheology with a view to better understanding the isothermal cure characteristics. The results demonstrate the influence of elastomer type, cure temperature, protein loading, and glycine loading on isothermal cure properties. By measuring the cure time required to achieve tan delta values representative of early and late-stage cure conditions, a ratio t(1)/t(2) was defined that allowed the cure characteristics of the various systems to be compared. Sustained in vitro release of BSA from glycine-loaded silicone elastomer covered rod devices was also demonstrated over 14 days. (C) 2010 Wiley Periodicals, Inc. J Appl Polym Sci 116: 2320-2327, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of a water-soluble, thermo-responsive polymer as a highly sensitive fluorescence-lifetime probe of microfluidic temperature is demonstrated. The fluorescence lifetime of poly(N-isopropylacrylamide) labelled with a benzofurazan fluorophore is shown to have a steep dependence on temperature around the polymer phase transition and the photophysical origin of this response is established. The use of this unusual fluorescent probe in conjunction with fluorescence lifetime imaging microscopy (FLIM) enables the spatial variation of temperature in a microfluidic device to be mapped, on the micron scale, with a resolution of less than 0.1 degrees C. This represents an increase in temperature resolution of an order of magnitude over that achieved previously by FLIM of temperature-sensitive dyes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main curative therapy for patients with nonsmall cell lung cancer is surgery. Despite this, the survival rate is only 50%, therefore it is important to more efficiently diagnose and predict prognosis for lung cancer patients. Raman spectroscopy is useful in the diagnosis of malignant and premalignant lesions. The aim of this study is to investigate the ability of Raman microscopy to diagnose lung cancer from surgically resected tissue sections, and predict the prognosis of these patients. Tumor tissue sections from curative resections are mapped by Raman microscopy and the spectra analzsed using multivariate techniques. Spectra from the tumor samples are also compared with their outcome data to define their prognostic significance. Using principal component analysis and random forest classification, Raman microscopy differentiates malignant from normal lung tissue. Principal component analysis of 34 tumor spectra predicts early postoperative cancer recurrence with a sensitivity of 73% and specificity of 74%. Spectral analysis reveals elevated porphyrin levels in the normal samples and more DNA in the tumor samples. Raman microscopy can be a useful technique for the diagnosis and prognosis of lung cancer patients receiving surgery, and for elucidating the biochemical properties of lung tumors. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3323088]

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contemporary medical science is reliant upon the rational selection and utilization of devices, and therefore, an increasing need has developed for in vitro systems aimed at replicating the conditions to which urological devices will be subjected to during their use in vivo. We report the development and validation of a novel continuous flow encrustation model based on the commercially available CDC biofilm reactor. Proteus mirabilis-induced encrustation formation on test biomaterial sections under varying experimental parameters was analyzed by X-ray diffraction, infrared- and Raman spectroscopy and by scanning electron microscopy. The model system produced encrusted deposits similar to those observed in archived clinical samples. Results obtained for the system are highly reproducible with encrustation being rapidly deposited on test biomaterial sections. This model will have utility in the rapid screening of encrustation behavior of biomaterials for use in urological applications. (C) 2010 Wiley Periodicals. Inc. J Biomed Mater Res Part B: Appl Biomater 93B: 128-140, 2010