959 resultados para METALLIC STENT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a novel repair of an anterior inflammatory tracheal defect with mediastinitis, which occurred after external tracheal suspension of localized intrathoracic tracheomalacia. The malacic tracheal segment of 4-cm length containing the inflammatory tracheal defect was noncircumferentially resected. A temporary endotracheal silicone stent was introduced, and the trachea was closed by a pedicled pectoralis muscle flap reinforced with an embedded rib segment. Retrieval of the stent 5 months postoperatively resulted in a re-epithelialized, persistently stable, noncollapsible tracheal segment that showed the same diameter and configuration as the nonreconstructed part of the trachea.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter stent-valve implantation in stenosed congenital bicuspid aortic valves is under debate. Heavily calcified elliptic bicuspid valves represent a contraindication to catheter-based valve therapies because of a risk of stent-valve displacement, distortion, or malfunctioning after the implantation. In this case report we illustrate our experience with a patient suffering from stenosed congenital bicuspid aortic valve who successfully underwent a transapical 26-mm Edwards Sapien stent-valve (Edwards Lifesciences Inc, Irvine, CA) implantation. Postoperative distortion, malfunctioning, and paravalvular leaks were not detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les empreses sempre han buscat com optimitzar el màxim els seus recursos i ser més eficients a la hora de realitzar les tasques que li han estat encomanades. És per aquest motiu que constantment les empreses realitzen estudis i valoracions de com poder millorar dia a dia. Aquest fet no és diferenciador a l’empresa Serralleria i Alumini Vilaró (S.A.V), que dia a dia estudia com optimitzar els seus processos o de vegades introduir-ne de nous per tal d’expandir la seva oferta de serveis. L’empresa és dedica a la fabricació de peces metàl•liques el procés ja sigui només de tall i mecanitzat, plegat, soldadura, acabats en inoxidable, pintura i fins i tot embalatge pel que fa a la part productiva, respecte a la part d’oficina tècnica també ofereix serveis de desenvolupament de productes segons especificacions del client i reenginyeria de qualsevol producte, analitzant la part que és vol millorar. En l’actualitat l’empresa ha detectat una mancança que creu que es podria solucionar, el problema és que l’empresa disposa de varies màquines de tall, entre les quals hi ha una màquina de tall làser i el problema principal és que la càrrega de les planxes del calaix de magatzem a la bancada de la màquina es realitza o bé manualment o a través d’un gripper sostingut al pont grua, depenent del pes de la planxa a transportar. L’objectiu principal d’aquest treball és fer el disseny d’una màquina que permeti automatitzar el procés de transportar la planxa metàl•lica del calaix de magatzem dipositat sobre una taula mòbil a la bancada de la màquina de tall. El disseny que pretenem fer és complet començant per fer un disseny estructural de la màquina més els seus respectius càlculs, moviments que volem aconseguir, tria de components ( motors, sensors ...), elaboració d’un pressupost per poder fer una estimació i finalment la elaboració del programa de control de tota la màquina més la interacció amb la màquina a través d’una pantalla tàctil. Es a dir, el que pretenem és realitzar un projecte que puguem fabricar en la realitat utilitzant tota la informació continguda dins del mateix

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. BACKGROUND: Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. METHODS: Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). RESULTS: At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). CONCLUSIONS: Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Transcatheter aortic valve replacement (TAVR) provides good results in selected high-risk patients. However, it is unclear whether this procedure carries advantages in extreme-risk profile patients with logistic EuroSCORE above 35%. METHODS: From January 2009 to July 2011, of a total number of 92 transcatheter aortic valve procedures performed, 40 'extreme-risk' patients underwent transapical TAVR (TA-TAVR) (EuroSCORE above 35%). Variables were analysed as risk factors for hospital and mid-term mortality, and a 2-year follow-up (FU) was obtained. RESULTS: The mean age was: 81 ± 10 years. Twelve patients (30%) had chronic pulmonary disease, 32 (80%) severe peripheral vascular disease, 14 (35%) previous cardiac surgery, 19 (48%) chronic renal failure (2 in dialysis), 7 (17%) previous stroke (1 with disabilities), 3 (7%) a porcelain aorta and 12 (30%) were urgent cases. Mean left ventricle ejection fraction (LVEF) was 49 ± 13%, and mean logistic EuroSCORE was 48 ± 11%. Forty stent-valves were successfully implanted with six Grade-1 and one Grade-2 paravalvular leakages (success rate: 100%). Hospital mortality was 20% (8 patients). Causes of death following the valve academic research consortium (VARC) definitions were: life-threatening haemorrhage (1), myocardial infarction (1), sudden death (1), multiorgan failure (2), stroke (1) and severe respiratory dysfunction (2). Major complications (VARC definitions) were: myocardial infarction for left coronary ostium occlusion (1), life-threatening bleeding (2), stroke (2) and acute kidney injury with dialysis (2). Predictors for hospital mortality were: conversion to sternotomy, life-threatening haemorrhage, postoperative dialysis and long intensive care unit (ICU) stay. Variables associated with hospital mortality were: conversion to sternotomy (P = 0.03), life-threatening bleeding (P = 0.02), acute kidney injury with dialysis (P = 0.03) and prolonged ICU stay (P = 0.02). Mean FU time was 24 months: actuarial survival estimates for all-cause mortality at 6 months, 1 year, 18 months and 2 years were 68, 57, 54 and 54%, respectively. Patients still alive at FU were in good clinical condition, New York Heart Association (NYHA) class 1-2 and were never rehospitalized for cardiac decompensation. CONCLUSIONS: TA-TAVR in extreme-risk patients carries a moderate risk of hospital mortality. Severe comorbidities and presence of residual paravalvular leakages affect the mid-term survival, whereas surviving patients have an acceptable quality of life without rehospitalizations for cardiac decompensation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditionally, the transcatheter aortic valve replacement is performed through a transapical, a transfemoral or a trans-subclavian approach. Recently, the transaortic approach for transcatheter aortic valve replacement through the distal part of the ascending aorta was successfully implemented in order to avoid peripheral vascular access-related complications and apical life-threatening haemorrhage. The Sapien? stent valve has great transaortic potential because it can be loaded 'upside down' in different generations of delivery systems. However, because of their health regulatory systems and despite the launch, in 2012, of the latest generation of the Ascendra? delivery system, the Ascendra+?, specifically designed for transapical and transaortic valve placements, several countries are still using the first generations of Ascendra? (Ascendra? 1 and 2). This device was specifically designed for transapical procedures, and retrograde stent-valve positioning through the stenotic aortic valve may be very challenging and risk the integrity of the aorta. We describe the manoeuvre required in order to pass the stenotic aortic valve safely in a retrograde direction using the Sapien? stent valve and the first generations of Ascendra?.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The industrial refining of kaolin involves the removal of iron oxides and hydroxides along with other impurities that cause discoloration of the final product and depreciate its commercial value, particularly undesirable if destined to the paper industry. The chemical leaching in the industrial processing requires treatments with sodium hyposulfite, metallic zinc, or sulfuric and phosphoric acids, in order to reduce, dissolve and remove ferruginous compounds. To mitigate the environmental impact, the acidic effluent from the leaching process must be neutralized, usually with calcium oxide. The resulting solid residue contains phosphorous, zinc, and calcium, among other essential nutrients for plant growth, suggesting its use as a macro and micronutrient source. Samples of such a solid industrial residue were used here to evaluate their potential as soil fertilizer in an incubation greenhouse experiment with two soil samples (clayey and medium-textured). The small pH shift generated by applying the residue to the soil was not a limiting factor for its use in agriculture. The evolution of the concentrations of exchangeable calcium, and phosphorous and zinc extractability by Mehlich-1 extractant during the incubation period confirms the potential use of this industrial residue as agricultural fertilizer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Results of some PCI clinical trials indicated more procedure related complications and worse clinical outcomes in women than men, but due to a lower representation of female patients this question still remains open. We aimed toinvestigate characteristics and early and late clinical outcomes in female patients as compared to male when treated in a real life setting with a new generation DES.Methods: Among 3069 consecutive patients treated with Nobori DES, and enrolled in NOBORI 2 study, 675 were female. The primary endpoint of the study is target lesion failure (TLF), a composite of cardiac death, MI and target lesion revascularization (TLR) at 12 months. Data are entered in an electronic database; all adverse events are adjudicated by an independent clinical event committee and independent corelabs analyse all angiograms.Results: Compared to male patients, female patients were significantly older (68±10 vs ± 63±11 years; p<0.001), had higher incidence of diabetes (37% vs 27%; p<0.001) and hypertension (75% vs 66%; p<0.001), but lower frequency of previous MI, PCI/CABG and smoking history. Lesion characteristics were similar in two genders, except for lesions located at bifurcation which were more frequent inmale patients (22% vs 15% inmale and female patients respectively; p<0.001). Majority of QCA assessed parameters were similar with the exception for RVD, post-procedure MLD in-segment and %DS in-stent which were significantly lower in female patients (p<0.05 for all). In table 1 results at 6 months follow-up are presented and at the time of presentation 1 year results will be available. Table 1. Clinical results at 6 months follow-up Male (n=2394) Female (n=675) P value Cardiac Death 12 (0.5%) 5 (0.7%) 0.5550 MI 5 (2.1%) 4 (1.3%) 0.5089 TLR rate 17 (0.7%) 13 (1.9%) 0.0124 TLF rate 44 (1.8%) 17 (2.5%) 0.2745 Stent Thrombosis 12 (0.5%) 6 (0.9%) 0.2548Conclusions: Results indicate that there are differences in the demographics and risk factors in female and male patient's population. The frequency of adverse events at 6 months is low in both populations, showing trend toward slightly higher rate in female patients, particularly for target lesion revascularization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silver has been demonstrated to be a powerful cationization agent in mass spectrometry (MS) for various olefinic species such as cholesterol and fatty acids. This work explores the utility of metallic silver sputtering on tissue sections for high resolution imaging mass spectrometry (IMS) of olefins by laser desorption ionization (LDI). For this purpose, sputtered silver coating thickness was optimized on an assorted selection of mouse and rat tissues including brain, kidney, liver, and testis. For mouse brain tissue section, the thickness was adjusted to 23 ± 2 nm of silver to prevent ion suppression effects associated with a higher cholesterol and lipid content. On all other tissues, a thickness of at 16 ± 2 nm provided the best desorption/ionization efficiency. Characterization of the species by MS/MS showed a wide variety of olefinic compounds allowing the IMS of different lipid classes including cholesterol, arachidonic acid, docosahexaenoic acid, and triacylglyceride 52:3. A range of spatial resolutions for IMS were investigated from 150 μm down to the high resolution cellular range at 5 μm. The applicability of direct on-tissue silver sputtering to LDI-IMS of cholesterol and other olefinic compounds presents a novel approach to improve the amount of information that can be obtained from tissue sections. This IMS strategy is thus of interest for providing new biological insights on the role of cholesterol and other olefins in physiological pathways or disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A route of accumulation and elimination of therapeutic engineered nanoparticles (NPs) may be the kidney. Therefore, the interactions of different solid-core inorganic NPs (titanium-, silica-, and iron oxide-based NPs) were studied in vitro with the MDCK and LLC-PK epithelial cells as representative cells of the renal epithelia. Following cell exposure to the NPs, observations include cytotoxicity for oleic acid-coated iron oxide NPs, the production of reactive oxygen species for titanium dioxide NPs, and cell depletion of thiols for uncoated iron oxide NPs, whereas for silica NPs an apparent rapid and short-lived increase of thiol levels in both cell lines was observed. Following cell exposure to metallic NPs, the expression of the tranferrin receptor/CD71 was decreased in both cells by iron oxide NPs, but only in MDCK cells by titanium dioxide NPs. The tight association, then subsequent release of NPs by MDCK and LLC-PK kidney epithelial cells, showed that following exposure to the NPs, only MDCK cells could release iron oxide NPs, whereas both cells released titanium dioxide NPs. No transfer of any solid-core NPs across the cell layers was observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new technology for the three-dimensional (3-D) stacking of very thin chips on a substrate is currently under development within the ultrathin chip stacking (UTCS) Esprit Project 24910. In this work, we present the first-level UTCS structure and the analysis of the thermomechanical stresses produced by the manufacturing process. Chips are thinned up to 10 or 15 m. We discuss potentially critical points at the edges of the chips, the suppression of delamination problems of the peripheral dielectric matrix and produce a comparative study of several technological choices for the design of metallic interconnect structures. The purpose of these calculations is to give inputs for the definition of design rules for this technology. We have therefore undertaken a programme that analyzes the influence of sundry design parameters and alternative development options. Numerical analyses are based on the finite element method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have studied the effects of rapid thermal annealing at 1300¿°C on GaN epilayers grown on AlN buffered Si(111) and on sapphire substrates. After annealing, the epilayers grown on Si display visible alterations with craterlike morphology scattered over the surface. The annealed GaN/Si layers were characterized by a range of experimental techniques: scanning electron microscopy, optical confocal imaging, energy dispersive x-ray microanalysis, Raman scattering, and cathodoluminescence. A substantial Si migration to the GaN epilayer was observed in the crater regions, where decomposition of GaN and formation of Si3N4 crystallites as well as metallic Ga droplets and Si nanocrystals have occurred. The average diameter of the Si nanocrystals was estimated from Raman scattering to be around 3¿nm. Such annealing effects, which are not observed in GaN grown on sapphire, are a significant issue for applications of GaN grown on Si(111) substrates when subsequent high-temperature processing is required.