Successful Transapical Aortic Valve Implantation in a Congenital Bicuspid Aortic Valve.
Data(s) |
2010
|
---|---|
Resumo |
Transcatheter stent-valve implantation in stenosed congenital bicuspid aortic valves is under debate. Heavily calcified elliptic bicuspid valves represent a contraindication to catheter-based valve therapies because of a risk of stent-valve displacement, distortion, or malfunctioning after the implantation. In this case report we illustrate our experience with a patient suffering from stenosed congenital bicuspid aortic valve who successfully underwent a transapical 26-mm Edwards Sapien stent-valve (Edwards Lifesciences Inc, Irvine, CA) implantation. Postoperative distortion, malfunctioning, and paravalvular leaks were not detected. |
Identificador |
https://serval.unil.ch/?id=serval:BIB_88A262DD31A4 isbn:1552-6259[electronic], 0003-4975[linking] pmid:20667364 doi:10.1016/j.athoracsur.2009.12.080 isiid:000280575100041 |