958 resultados para High reliability
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente, perfil Sanitária
Time-frequency and time-scale characterisation of the beat-by-beat high-resolution electrocardiogram
Resumo:
Proceedings of the Sixth Portuguese Conference on Bioemedical Engineering faro, Portugal
Resumo:
Drilling of carbon fibre/epoxy laminates is usually carried out using standard drills. However, it is necessary to adapt the processes and/or tooling as the risk of delamination, or other damages, is high. These problems can affect mechanical properties of produced parts, therefore, lower reliability. In this paper, four different drills – three commercial and a special step (prototype) – are compared in terms of thrust force during drilling and delamination. In order to evaluate damage, enhanced radiography is applied. The resulting images were then computational processed using a previously developed image processing and analysis platform. Results show that the prototype drill had encouraging results in terms of maximum thrust force and delamination reduction. Furthermore, it is possible to state that a correct choice of drill geometry, particularly the use of a pilot hole, a conservative cutting speed – 53 m/min – and a low feed rate – 0.025 mm/rev – can help to prevent delamination.
Resumo:
Relatório da Prática Profissional Supervisionada Mestrado em Educação Pré-Escolar
Resumo:
IEEE Electron Device Letters, VOL. 29, NO. 9,
Resumo:
The economic development of a region depends on the speed that people and goods can travel. The reduction of people and goods travel time can be achieved by planning smooth road layouts, which are obtained by crossing natural obstacles such as hills, by tunneling at great depths, and allowing the reduction of the road alignment length. The stress state in rock masses at such depths, either because of the overburden or due to the tectonic conditions of the rock mass induces high convergences of the tunnel walls. These high convergence values are incompatible with the supports structural performance installed in the excavation stabilization. In this article it is intended to evaluate and analyze some of the solutions already implemented in several similar geological and geotechnical situations, in order to establish a methodological principle for the design of the tunnels included in a highway section under construction in the region influenced by the Himalayas, in the state of Himachal Pradesh (India) and referenced by "four laning of Kiratpur to Ner Chowk section".
Resumo:
As engrenagens com dentes em evolvente de círculo têm sido e continuarão a ser um dos órgãos de máquinas mais utilizados em Engenharia Mecânica. O seu elevado uso e a sua versatilidade têm promovido o seu desenvolvimento permitido avanços no que diz respeito à sua eficiência, durabilidade, capacidade de carga e fiabilidade. Porém, para além da relativa facilidade de se poder encontrar literatura relativamente às engrenagens, o seu cálculo é complexo. São necessários conhecimentos da geometria de rodas dentadas e dos materiais envolvidos no seu fabrico. Este trabalho tem por objectivo o estudo de engrenagens de dentado recto com o desenvolvimento de uma ferramenta com base no software MatLab®. Esta ferramenta permitirá ao utilizador estudar a influência de condições de funcionamento e parâmetros da engrenagem na resistência à fadiga superficial e de flexão.
Resumo:
Empowered by virtualisation technology, cloud infrastructures enable the construction of flexi- ble and elastic computing environments, providing an opportunity for energy and resource cost optimisation while enhancing system availability and achieving high performance. A crucial re- quirement for effective consolidation is the ability to efficiently utilise system resources for high- availability computing and energy-efficiency optimisation to reduce operational costs and carbon footprints in the environment. Additionally, failures in highly networked computing systems can negatively impact system performance substantially, prohibiting the system from achieving its initial objectives. In this paper, we propose algorithms to dynamically construct and readjust vir- tual clusters to enable the execution of users’ jobs. Allied with an energy optimising mechanism to detect and mitigate energy inefficiencies, our decision-making algorithms leverage virtuali- sation tools to provide proactive fault-tolerance and energy-efficiency to virtual clusters. We conducted simulations by injecting random synthetic jobs and jobs using the latest version of the Google cloud tracelogs. The results indicate that our strategy improves the work per Joule ratio by approximately 12.9% and the working efficiency by almost 15.9% compared with other state-of-the-art algorithms.
Resumo:
Dissertação apresentada na faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Para uma melhor avaliação e definição do plano de intervenção do indivíduo, é cada vez mais importante a existência instrumentos de avaliação válidos e fiáveis para a população portuguesa. Objetivo: Traduzir e adaptar para a população Portuguesa a escala Trunk Impairment Scale (TIS) em pacientes pós-AVE, e avaliar as propriedades psicométricas da mesma. Metodologia: A TIS foi traduzida para o Português e adaptada culturalmente para a população portuguesa. As propriedades psicométricas da mesma, incluindo validade, fiabilidade, concordância inter-observadores, consistência interna, sensibilidade, especificidade, poder de resposta, foram avaliadas numa população diagnosticada com AVE e num grupo de controlo de participantes saudáveis. Participaram neste estudo 80 indivíduos, divididos em dois grupos, nomeadamente indivíduos pós-AVE (40) e um grupo sem patologia (40). Os participantes foram submetidos à aplicação das escalas de Berg, Medida de Independência Funcional e Escala de Desempenho Físico Fugl Meyer e a TIS de modo a avaliar as propriedades psicométricas desta. As avaliações foram realizadas por duas fisioterapeutas experientes e o re-teste foi realizado após 48 horas. Os dados foram registados e trabalhados com o programa informático SPSS 21.0. Resultados: Relativamente aos valores obtidos, verificou-se que, quanto à consistência interna da TIS estes apresentam-se de forma moderada a elevada (alfa Cronbach = 0,909). Quanto à fiabilidade inter-observadores, os itens com menor valor são os itens 1 e 4 (0,759 e 0,527, respetivamente) e os itens com valor de Kappa mais alto são os itens 5 e 6 (0,830 e 0,893, respetivamente). Relativamente à validade de critério, verificou-se que não houve correlação entre a escala de Desempenho Físico Fugl-Meyer, a escala de Equilibrio de Berg e a Medida de Independência Funcional, ou seja, os valores obtidos r=0,166; r=0,017; r= -0,002, respetivamente. Quanto à validade de construção, constatou-se que o valor da mediana é mais elevado nos itens 1 a 5, logo sugere que haja diferenças entre o grupo de indivíduos pós-AVE e o grupo de indivíduos saudáveis (p<0,001). Entre os outros dois itens (6 e 7) não foram encontradas diferenças nas respostas nos dois grupos, sendo o valor de p > 0,001. Conclusão: Os resultados obtidos neste estudo sugerem que a versão portuguesa da TIS apresenta bons níveis de fiabilidade, consistência interna e também apresenta bons resultados no que refere à concordância inter-observadores.
Resumo:
15th International Conference on Mixed Design of Integrated Circuits and Systems, pp. 177 – 180, Poznan, Polónia
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde
Resumo:
In this paper analytical transient solutions of dynamic response of one-dimensional systems with sudden change of foundation stiffness are derived. In more details, cantilever dynamic response, expressed in terms of vertical displacement, is extended to account for elastic foundation and then two cantilever solutions, corresponding to beams clamped on left and right hand side, with different value of Winkler constant are connected together by continuity conditions. The internal forces, as the unknowns, can be introduced by the same values in both clamped beam solutions and solved. Assumption about time variation of internal forces at the section of discontinuity must be adopted and originally analytical solution will have to include numerical procedure.