996 resultados para Experimental Calibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigation of kerosene combustion in a Mach 2.5 flow was carried out using a model supersonic combustor with cross-section area of 51 mm?70 mm, with special emphases on the characterization of effervescent atomization and the flameholdering mechanism using different integrated fuel injector/flameholder cavity modules. Direct photography, Schlieren imaging, and Planar Laser Induced Fluorescence (PLIF) imaging of OH were utilized to examine the cavity characteristics and spray structure, with and without gas barbotage. Schlieren images illustrate the effectiveness of gas barbotage in facilitating atomization and the importance of secondary atomization when kerosene sprays interacting with a supersonic crossflow. OH-PLIF images further substantiate our previous finding that there exists a local high temperature radical pool within the cavity flameholder and this radical pool plays a crucial role in promoting kerosene combustion in a supersonic combustor. The present results also demonstrate that the cavity characteristics can be different in non-reacting and reacting supersonic flows. As such, the conventional definition of cavity characteristics based on non-reacting flows needs to be revised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:


A temperature-controlled poolboiling (TCPB) device was developed to perform poolboiling heat transfer studies at both normal gravity and microgravity. A platinum wire of 60 μm in diameter and 30 mm in length was simultaneously used as heaters and thermometers. The heater resistance, and thus the heater temperature, was kept constant by a feedback circuit. The fluid was R113 at 0.1 Mpa and subcooled by 24 nominally for all cases. The results of the experiments at both normal gravity and microgravityin the Drop Tower Beijing were presented. Nucleate and two-mode transition boiling were observed. For nucleate boiling, the heat transfer was slightly enhanced, namely no more than 10% increase of the heat flux was obtained inmicrogravity, while the bubble pattern is dramatically altered by the variation of the acceleration. For two-mode transition boiling, about 20% decrease of the heat flux was obtained, although the part of film boiling was receded inmicrogravity. A scale analysis on the Marangoni convection surrounding bubble in the process of subcooled nucleate poolboiling was also presented. The characteristic velocity of the lateral motion and its observability were obtained approximately. The predictions consist with theexperimental observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical diagnostic system consisting of the Michelson interferometer with the image processor has been developed for studying of the surface wave in the thermal capillary convection in a rectangular cavity. In this paper, the capillary convection, surface deformation and surface wave due to the different temperature between the two sidewalls have been investigated. The cavity is 52mm?42mm in horizontal cross section and 4mm in height. The temperature difference is increased gradually and flow in liquid layer will change from steady convection to unstable convection. The optical interference method measures the surface deformation and the surface wave of the convection. The deformation of the interference fringes, which produced by the meeting of the reflected light from the liquid surface and the reference light has been captured, and the surface deformation appears when the steady convection is developed. The surface deformation is enhanced with the increasing of the temperature difference, and then several knaggy peeks in the interference fringes appear and move from the heated side to the cooled side, it demonstrates that the surface wave is existed. The surface deformation, the wavelength, the frequency, and the wave amplitude of the surface wave have been calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experimental and theoretical investigations into the head-on collision between a landing droplet with another one resting on the PDMS substrate were addressed in this talk. The colliding process of the two droplets was recorded with highspeed camera. Four different responses after collision were observed in our experiments: complete rebound, coalescence, partial rebound with conglutination, and coalescence accompanied by conglutination. The contact time between the two colliding droplets was found to be in the range of 10-20 milliseconds. For the complete bouncing case, Hertz contact model was applied to estimate the contact time of the binary head-on colliding droplets with both the droplets considered as elastic bodies. The estimated contact time was in good agreement with the experimental result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flow-induced vibration of a cylinder with two degrees of freedom near a rigid wall under the action of steady flow is investigated experimentally. The vibration amplitude and frequency of the cylinder and the vortex shedding frequency at the wake flow region of the cylinder are measured. The influence of gap-to-diameter ratio upon the amplitude response is analyzed. The experimental results indicate that when the reduced velocity (Vr) is in the range of 1.2 < Vr < 2.6, only streamwise vibration with small amplitude occurs, whose frequency is quite close to its natural frequency in the still water. When the reduced velocity Vr > 3.4, both the streamwise and transverse vibrations of the cylinder occur. In this range, the amplitudes of transverse vibration are much larger than those of streamwise vibrations, and the amplitudes of the streamwise vibration also get larger than those at the range of 1.2 < Vr < 2.6. At the range of Vr > 3.4, the frequency of streamwise vibration undergoes a jump at certain values of Vr, at which the streamwise vibrating frequency is twice as much as the transverse one. However, when the streamwise vibration does not experience a jump, its frequency is the same as that of the transverse vibration. The maximum values of second streamwise and transverse vibration amplitudes increase with increasing gap-to-diameter ratios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very-High-Cycle Fatigue (VHCF) test for a medium carbon structural steel (40Cr) has been performed and a stepwise S-N curve was obtained by employing cantilever-type rotary bending fatigue machine with hourglass shape specimen. The S-N curve was well explained as a combination of curves for surface-induced fracture and interior inclusion-induced fracture with fish-eye patterns. The morphology of the fish-eye pattern was illustrated in order to clarify subsurface crack initiation and propagation behavior.