958 resultados para urine excretion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fasciola hepatica somatic antigen, its partially purified fractions and excretion-secretion products were investigated as to serological, electrophoretic and biological properties. In a Sephadex G-100 column (SG-100), Fasciola hepatica total antigen (FhTA) gave 5 fractions, and SDS-PAGE analysis showed they were glycoproteins ranging from 14 to 94 kDa molecular weight (MW). When these fractions were analyzed by enzyme linked immunotransfer blot (EITB) and immunodiffusion in gel (ID) with serum from immunized rats with FhTA, the presence of different antigenic components was revealed. In the SDS-PAGE of excretor-secretor antigen (ESA), it was possible to observe peptides from 12 to 22 kDa, which were also present in FhTA. When the FhTA, its fractions and the ESA were analyzed by EITB with the immune rat serum (IRS), it was observed that only some fractions of the SG-100 shared antigens with the FhTA and ESA. Moreover, DTH and ITH responses were studied in FhTA immunized rats challenged with these different antigen components, revealing that the protein/carbohydrate ratio is important for inducing DTH response. The ESA was the most active component in the DTH and ITH response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mice infected with about 90 cercariae of Schistosoma mansoni (LE strain) were treated during five consecutive days with dexamethasone (50 mg/Kg, subcutaneously), starting on the 42th day of infection. Groups of five mice were then daily sacrificed from the first day after onset of treatment until the first day after. The perfusion of the portal system was performed and a piece of the intestine was processed for qualitative and quantitative oograms. This treatment carries to larger numbers of eggs in the tissues of treated mice, when compared with untreated groups. No changes were observed in the kinetics of oviposition, as all stages of viable eggs were observed in the tissues of treated and control mice. These data reinforce the hypothesis of a partial blockade of the egg excretion in immunossupressed mice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anti-Toxocara antibody production and persistence were studied in experimental infections of BALB/c mice, according to three different schedules: Group I (GI) - 25 mice infected with 200 T. canis eggs in a single dose; Group II (GII) 25 mice infected with 150 T. canis eggs given in three occasions, 50 in the 1st, 50 in the 5th and 50 in the 8th days; Group III (GIII) - 25 mice also infected with 150 T. canis eggs, in three 50 eggs portions given in the 1st, 14th and 28th days. A 15 mice control group (GIV) was maintained without infection. In the 30th, 50th, 60th, 75th, 105th and 180th post-infection days three mice of the GI, GII and GIII groups and two mice of the control group had been sacrificed and exsanguinated for sera obtention. In the 360th day the remainder mice of the four groups were, in the same way, killed and processed. The obtained sera were searched for the presence of anti-Toxocara antibodies by an ELISA technique, using T. canis larvae excretion-secretion antigen. In the GI and GII, but not in the GIII, anti-Toxocara antibodies had been found, at least, up to the 180th post-infection day. The GIII only showed anti-Toxocara antibodies, at significant level, in the 30th post-infection day.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Norfloxacina (NFX) é um antibiótico antibacteriano indicado para combater bactérias Gram-negativas e amplamente utilizado para o tratamento de infeções no trato respiratório e urinário. Com a necessidade de realizar estudos clínicos e farmacológicos esenvolveram-se métodos de análise rápida e sensitiva para a determinação da Norfloxacina. Neste trabalho foi desenvolvido um novo sensor eletroquímico sensível e seletivo para a deteção da NFX. O sensor foi construído a partir de modificações efetuadas num elétrodo de carbono vítreo. Inicialmente o elétrodo foi modificado com a deposição de uma suspensão de nanotubos de carbono de paredes múltiplas (MWCNT) de modo a aumentar a sensibilidade de resposta analítica. De seguida um filme polímerico molecularmente impresso (MIP) foi preparado por eletrodeposição, a partir de uma solução contendo pirrol (monómero funcional) e NFX (template). Um elétrodo de controlo não impresso foi também preparado (NIP). Estudouse e caraterizou-se a resposta eletroquímica do sensor para a oxidação da NFX por voltametria de onda quadrada. Foram optimizados diversos parâmetros experimentais, tais como, condições ótimas de polimerização, condições de incubação e condições de extração. O sensor apresenta um comportamento linear entre a intensidade da corrente do pico e o logaritmo da concentração de NFX na gama entre 0,1 e 8μM. Os resultados obtidos apresentam boa precisão, com repetibilidade inferior a 6% e reprodutibilidade inferior a 9%. Foi calculado a partir da curva de calibração um limite de deteção de 0,2 μM O método desenvolvido é seletivo, rápido e de fácil manuseamento. O sensor molecularmente impresso foi aplicado com sucesso na deteção da NFX em amostras de urina real e água.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho descrito compreende o desenvolvimento de um anticorpo plástico (MIP, do inglês Molecularly Imprinted Polymer) para o antigénio carcinoembrionário (CEA, do inglês Carcinoembriogenic Antigen) e a sua aplicação na construção de dispositivos portáteis, de tamanho reduzido e de baixo custo, tendo em vista a monitorização deste biomarcador do cancro do colo-retal em contexto Point-of-Care (POC). O anticorpo plástico foi obtido por tecnologia de impressão molecular orientada, baseada em eletropolimerização sobre uma superfície condutora de vidro recoberto por FTO. De uma forma geral, o processo foi iniciado pela electropolimerização de anilina sobre o vidro, seguindo-se a ligação por adsorção do biomarcador (CEA) ao filme de polianilina, com ou sem monómeros carregados positivamente (Cloreto de vinilbenziltrimetilamónio, VB). A última fase consistiu na electropolimerização de o-fenilenodiamina (oPD) sobre a superfície, seguindo-se a remoção da proteína por clivagem de ligações peptídicas, com o auxílio de tripsina. A eficiência da impressão do biomarcador CEA no material polimérico foi controlada pela preparação de um material análogo, NIP (do inglês, Non-Imprinted Polymer), no qual nem a proteína nem o monómero VB estavam presentes. Os materiais obtidos foram caracterizados quimicamente por técnicas de Infravermelho com Transformada de Fourier (FTIR, do inglês, Fourier Transform Infrared Spectroscopy) e microscopia confocal de Raman. Os materiais sensores preparados foram entretanto incluídos em membranas poliméricas de Poli(cloreto de vinilo) (PVC) plastificado, para construção de sensores (biomiméticos) seletivos a CEA, tendo-se avaliado a resposta analítica em diferentes meios. Obteve-se uma boa resposta potenciométrica em solução tampão de Ácido 4-(2-hidroxietil)piperazina-1-etanosulfónico (HEPES), a pH 4,4, com uma membrana seletiva baseada em MIP preparada com o monómero carregado VB. O limite de deteção foi menor do que 42 pg/mL, observando-se um comportamento linear (versus o logaritmo da concentração) até 625 pg/mL, com um declive aniónico igual a -61,9 mV/década e r2>0,9974. O comportamento analítico dos sensores biomiméticos foi ainda avaliado em urina, tendo em vista a sua aplicação na análise de CEA em urina. Neste caso, o limite de deteção foi menor do que 38 pg/mL, para uma resposta linear até 625 pg/mL, com um declive de -38,4 mV/década e r2> 0,991. De uma forma geral, a aplicação experimental dos sensores biomiméticos evidenciou respostas exatas, sugerindo que os biossensores desenvolvidos prossigam estudos adicionais tendo em vista a sua aplicação em amostras de indivíduos doentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Pentavalent antimonials have became of basic importance for the treatment of leishmaniasis. Their most severe side effects have been reported to be increased hepatic enzyme levels and electrocardiographic abnormalities. Nephrotoxicity has been rarely related. Observations: We report a case of generalized cutaneous leishmaniasis involving a 50-year old male patient who was submitted to treatment with meglumine antimoniate (Glucantime). He developed acute renal failure (ARF) due to acute tubular necrosis (ATN), followed by death after receiving a total of 53 ampoules of Glucantime. Conclusions: The treatment with Glucantime was responsible by ARF diagnosed in this patient. The previous urine osmolarity and serum creatinine levels were normal and the autopsy showed ATN. It should be pointed out if ARF may also be explained by massive deposits of immunocomplexes by leishmania antibodies and antigens due to the antigenic break by the antimonial compound, since our patient presented countless lesions covering the entire tegument, similar to the Hexheimer phenomenon, but at the autopsy no glomerular alterations were seen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cytomegalovirus (CMV) infection is the most common congenital infection, affecting 0.4% to 2.3% newborns. Most of them are asymptomatic at birth, but later 10% develop handicaps, mainly neurological disturbances. Our aim was to determine the prevalence of CMV shed in urine of newborns from a neonatal intensive care unit using the polymerase chain reaction (PCR) and correlate positive cases to some perinatal aspects. Urine samples obtained at first week of life were processed according to a PCR protocol. Perinatal data were collected retrospectively from medical records. Twenty of the 292 cases (6.8%) were CMV-DNA positive. There was no statistical difference between newborns with and without CMV congenital infection concerning birth weight (p=0.11), gestational age (p=0.11), Apgar scores in the first and fifth minutes of life (p=0.99 and 0.16), mother's age (p=0.67) and gestational history. Moreover, CMV congenital infection was neither related to gender (p=0.55) nor to low weight (<2,500g) at birth (p=0.13). This high prevalence of CMV congenital infection (6.8%) could be due to the high sensitivity of PCR technique, the low socioeconomic level of studied population or the severe clinical status of these newborns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluates the transmission of CMV infection in 120 children aged 1 to 15 years with Down syndrome who attended a day-care center for handicapped children in São Paulo, Brazil. A blood sample was obtained from each children at the beginning of the study for detection of IgG and IgM cytomegalovirus (CMV) antibodies by an immunofluorescence assay. Samples of saliva and urine were obtained every 3 months from the children with CMV antibodies to detect shedding of the virus by culture in human foreskin fibroblasts, by detection of pp65 CMV-antigen and by a nested PCR assay. The prevalence of anti CMV-IgG antibodies was 76.6% (92/120), and IgM anti-CMV antibodies were detected in 13% (12/92) of the seropositive children. During the first viral evaluation, CMV was detected in the urine and/or saliva in 39/90 (43.3%) of the seropositive children. In the second and third evaluations, CMV was detected in 41/89 (46%) and in 35/89 (39.3%) children, respectively. Detection of CMV was shown both in urine and saliva in 28/39 (71.8%), 19/41(46.3%) and 20/35 (57.1%) of the children excreting the virus, respectively. Additionally, in 33/49 (67.4%) of the excreters CMV could be demonstrated in urine or saliva in at least two out of the three virological evaluations carried out sequentially in a six month period. Of the 28 initially seronegative children, 26 were re-examined for anti-CMV IgG antibodies about 18 months after the negative sample; seroconversion was found in 10/26 (38.5%). Taking all 536 samples of urine or saliva examined by virus culture and pp65 antigen detection during the study into account, 159 (29.6%) were positive by virus culture and 59 (11%) gave a positive result with the pp65 assay. These data demonstrate the high prevalence of CMV shedding and the high risk of CMV infection in children with Down syndrome attending a day-care center for mentally handicapped patients. The virus culture was more sensitive than the pp65 CMV antigen assay for CMV detection in both urine and saliva samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho descreve o desenvolvimento de um material sensor para creatinina por impressão molecular em estrutura polimérica (MIP) e a sua aplicação no desenvolvimento de um dispositivo de natureza potenciométrica para a determinação da molécula alvo em fluidos biológicos. A creatinina é um dos biomarcadores mais utilizados no acompanhamento da doença renal, já que é um bom indicador da taxa de filtração glomerular (TFG). Os materiais biomiméticos desenhados para interação com a creatinina foram obtidos por polimerização radicalar, recorrendo a monómeros de ácido metacríclico ou de vinilpiridina e a um agente de reticulação apropriado. De modo a aferir o efeito da impressão da creatinina na resposta dos materiais MIP à sua presença, foram também preparados e avaliados materiais de controlo, obtidos sem impressão molecular (NIP). O controlo da constituição química destes materiais, incluindo a extração da molécula impressa, foi realizado por Espectroscopia de Raman e de Infravermelho com Transformada de Fourrier. A afinidade de ligação entre estes materiais e a creatinina foi também avaliada com base em estudos cinéticos. Todos os materiais descritos foram integrados em membranas selectivas de elétrodos seletivos de ião, preparadas sem ou com aditivo iónico lipófilo, de carga negativa ou positiva. A avaliação das características gerais de funcionamento destes elétrodos, em meios de composição e pH diferentes, indicaram que as membranas com materiais impressos e aditivo aniónico eram as únicas com utilidade analítica. Os melhores resultados foram obtidos em solução tampão Piperazine-N,N′-bis(2- ethanesulfonic acid), PIPES, de pH 2,8, condição que permitiu obter uma resposta quasi-Nernstiana, a partir de 1,6×10-5 mol L-1. Estes elétrodos demonstraram ainda uma boa selectividade ao apresentaram uma resposta preferencial para a creatinina quando na presença de ureia, carnitina, glucose, ácido ascórbico, albumina, cloreto de cálcio, cloreto de potássio, cloreto de sódio e sulfato de magnésio. Os elétrodos foram ainda aplicados com sucesso na análise de amostras sintéticas de urina, quando os materiais sensores eram baseados em ácido metacrilico, e soro, quando os materiais sensores utilizados eram baseados em vinilpiridina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

6th Graduate Student Symposium on Molecular Imprinting

Relevância:

10.00% 10.00%

Publicador:

Resumo:

XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.