995 resultados para pollution monitoring
Resumo:
The current study was initiated to quantify the stresses induced in critical details on the reinforcing jacket and the tower itself through the use of field instrumentation, load testing, and long-term monitoring. Strain gages were installed on the both the tower and the reinforcing jacket. Additional strain gages were installed on two anchor rods. Tests were conducted with and without the reinforcing jacket installed. Data were collected from all strain gages during static load testing and were used to study the stress distribution of the tower caused by known loads, both with and without the reinforcing jacket. The tower was tested dynamically by first applying a static load, and then quickly releasing the load causing the tower to vibrate freely. Furthermore, the tower was monitored over a period of over 1 year to obtain stress range histograms at the critical details to be used for a fatigue evaluation. Also during the long-term monitoring, triggered time-history data were recorded to study the wind loading phenomena that excite the tower.
Resumo:
A good system of preventive bridge maintenance enhances the ability of engineers to manage and monitor bridge conditions, and take proper action at the right time. Traditionally infrastructure inspection is performed via infrequent periodical visual inspection in the field. Wireless sensor technology provides an alternative cost-effective approach for constant monitoring of infrastructures. Scientific data-acquisition systems make reliable structural measurements, even in inaccessible and harsh environments by using wireless sensors. With advances in sensor technology and availability of low cost integrated circuits, a wireless monitoring sensor network has been considered to be the new generation technology for structural health monitoring. The main goal of this project was to implement a wireless sensor network for monitoring the behavior and integrity of highway bridges. At the core of the system is a low-cost, low power wireless strain sensor node whose hardware design is optimized for structural monitoring applications. The key components of the systems are the control unit, sensors, software and communication capability. The extensive information developed for each of these areas has been used to design the system. The performance and reliability of the proposed wireless monitoring system is validated on a 34 feet span composite beam in slab bridge in Black Hawk County, Iowa. The micro strain data is successfully extracted from output-only response collected by the wireless monitoring system. The energy efficiency of the system was investigated to estimate the battery lifetime of the wireless sensor nodes. This report also documents system design, the method used for data acquisition, and system validation and field testing. Recommendations on further implementation of wireless sensor networks for long term monitoring are provided.
Resumo:
The goal of this work was to move structural health monitoring (SHM) one step closer to being ready for mainstream use by the Iowa Department of Transportation (DOT) Office of Bridges and Structures. To meet this goal, the objective of this project was to implement a pilot multi-sensor continuous monitoring system on the Iowa Falls Arch Bridge such that autonomous data analysis, storage, and retrieval can be demonstrated. The challenge with this work was to develop the open channels for communication, coordination, and cooperation of various Iowa DOT offices that could make use of the data. In a way, the end product was to be something akin to a control system that would allow for real-time evaluation of the operational condition of a monitored bridge. Development and finalization of general hardware and software components for a bridge SHM system were investigated and completed. This development and finalization was framed around the demonstration installation on the Iowa Falls Arch Bridge. The hardware system focused on using off-the-shelf sensors that could be read in either “fast” or “slow” modes depending on the desired monitoring metric. As hoped, the installed system operated with very few problems. In terms of communications—in part due to the anticipated installation on the I-74 bridge over the Mississippi River—a hardline digital subscriber line (DSL) internet connection and grid power were used. During operation, this system would transmit data to a central server location where the data would be processed and then archived for future retrieval and use. The pilot monitoring system was developed for general performance evaluation purposes (construction, structural, environmental, etc.) such that it could be easily adapted to the Iowa DOT’s bridges and other monitoring needs. The system was developed allowing easy access to near real-time data in a format usable to Iowa DOT engineers.
Resumo:
Therapeutic drug monitoring (TDM), i. e., the quantification of serum or plasma concentrations of medications for dose optimization, has proven a valuable tool for the patient-matched psychopharmacotherapy. Uncertain drug adherence, suboptimal tolerability, non-response at therapeutic doses, or pharmacokinetic drug-drug interactions are typical situations when measurement of medication concentrations is helpful. Patient populations that may predominantly benefit from TDM in psychiatry are children, pregnant women, elderly patients, individuals with intelligence disabilities, forensic patients, patients with known or suspected genetically determined pharmacokinetic abnormalities or individuals with pharmacokinetically relevant comorbidities. However, the potential benefits of TDM for optimization of pharmacotherapy can only be obtained if the method is adequately integrated into the clinical treatment process. To promote an appropriate use of TDM, the TDM expert group of the Arbeitsgemeinschaft für Neuropsychopharmakologie und Pharmakopsychiatrie (AGNP) issued guidelines for TDM in psychiatry in 2004. Since then, knowledge has advanced significantly, and new psychopharmacologic agents have been introduced that are also candidates for TDM. Therefore the TDM consensus guidelines were updated and extended to 128 neuropsychiatric drugs. 4 levels of recommendation for using TDM were defined ranging from "strongly recommended" to "potentially useful". Evidence-based "therapeutic reference ranges" and "dose related reference ranges" were elaborated after an extensive literature search and a structured internal review process. A "laboratory alert level" was introduced, i. e., a plasma level at or above which the laboratory should immediately inform the treating physician. Supportive information such as cytochrome P450 substrate and inhibitor properties of medications, normal ranges of ratios of concentrations of drug metabolite to parent drug and recommendations for the interpretative services are given. Recommendations when to combine TDM with pharmacogenetic tests are also provided. Following the guidelines will help to improve the outcomes of psychopharmacotherapy of many patients especially in case of pharmacokinetic problems. Thereby, one should never forget that TDM is an interdisciplinary task that sometimes requires the respectful discussion of apparently discrepant data so that, ultimately, the patient can profit from such a joint eff ort.
Resumo:
OBJECTIVE: To investigate whether HIV-infected patients on a stable and fully suppressive combination antiretroviral therapy (cART) regimen could safely be monitored less often than the current recommendations of every 3 months. DESIGN: Two thousand two hundred and forty patients from the EuroSIDA study who maintained a stable and fully suppressed cART regimen for 1 year were included in the analysis. METHODS: Risk of treatment failure, defined by viral rebound, fall in CD4 cell count, development of new AIDS-defining illness, serious opportunistic infection or death, in the 12 months following a year of a stable and fully suppressed regimen was assessed. RESULTS: One hundred thirty-one (6%) patients experienced treatment failure in the 12 months following a year of stable therapy, viral rebound occurred in 99 (4.6%) patients. After 3, 6 and 12 months, patients had a 0.3% [95% confidence interval (CI) 0.1-0.5], 2.2% (95% CI 1.6-2.8) and 6.0% (95% CI 5.0-7.0) risk of treatment failure, respectively. Patients who spent more than 80% of their time on cART with fully suppressed viraemia prior to baseline had a 38% reduced risk of treatment failure, hazard ratio 0.62 (95% CI 0.42-0.90, P = 0.01). CONCLUSION: Patients who have responded well to cART and are on a well tolerated and durably fully suppressive cART regimen have a low chance of experiencing treatment failure in the next 3-6 months. Therefore, in this subgroup of otherwise healthy patients, it maybe reasonable to extend visit intervals to 6 months, with cost and time savings to both the treating clinics and the patients.
Resumo:
En 1981, le gouvernement de l'Alberta a amélioré la surveillance de la pointe sud « South Peak » de la montagne Turtle, sur la frontière sud du glissement Frank de 1903. Le programme de surveillance vise à comprendre les taux de déformation des fissures larges et profondes sur « South Peak », et à prédire une seconde avalanche rocheuse sur la montagne. Le programme de surveillance consiste à installer un complément de points statiques et de stations suivies à distance, qui sont mesurés périodiquement. Des données climatiques, microsismiques et de déformation sont recueillies automatiquement à intervalles journaliers, et sont archivées. À la fin des années 1980, le financement pour le développement du programme de surveillance a cessé et quelques installations se sont détériorées. Entre mai 2004 et septembre 2006, des lectures sur les points de surveillance encore fonctionnels ont été compilées et interprétées. De plus, les lectures prélevées auparavant ont été réinterprétées à partir des connaissances récentes sur les modèles de mouvement à court terme et les influences climatiques. Ces observations ont été comparées à des récentes observations aériennes d'un modèle digital d'élévation, provenant de « light detection and ranging (LiDAR) », et des photos de terrain, afin d'estimer plus précisément les taux, l'étendue et la distribution des mouvements pour les derniers 25 ans.
Resumo:
Multiple motor function and strength assessment tools exist for the evaluation of neuromuscular diseases, but most do not directly assess functional ability in the patients' daily physical activity in their home environment. In this study our aim was to assess: 1) the feasibility and accuracy of physical activity monitoring during two days in a home environment of five DMD patients using a non-commercialized monitor containing a 3D accelerometer and a gyroscope, 2) if a difference in the physical activity parameters could be measured before and one month after starting prednisolone. We reliably quantified the time spend sitting, standing, lying, walking, the number of steps taken, the cadence, the number of walking episodes and their duration as well as how these were distributed over the day. Parameters possibly reflecting endurance, such as the duration of the walking episodes or the succession of two or three walking episodes lasting more than 30 s were the most improved after prednisolone treatment. This degree of detailed determination of physical activity in a home environment has not been previously reported in neuromuscular disorders to our knowledge and some of the reported parameters are potential new outcome measures in clinical trials.
Resumo:
Im Spätsommer 2008 wurde eine Studie zur Passivrauchbelastung in Zürcher Gaststätten durchgeführt. In dieser Zeit werden die geringsten Konzentrationen erwartet wegen offenen Fenster und wenig Gästen im Inneren von Gebäuden. In 102 Gaststätten wurde PM2.5 Feinstaub im Nichtraucherbereich zu verschiedenen Tageszeiten und Wochentagen gemessen. Die Innenluftkonzentration betrug durchschnittlich 64.7 microg/m3 mit Maximalwerten von über 450 microg/m3. Raucher wurden als wesentliche Quelle identifiziert und trugen im Schnitt 15 microg/m3 zur PM2.5-Belastung bei. Für einen durchschnittlichen Angestellten bedeuten diese Werte eine Erhöhung der Feinstaubbelastung um fast 20%, was einer Erhöhung des Mortalitätsrisikos um rund 10% entspricht. Die Studie zeigt, dass Raucher massgeblich zur Feinstaubbelastung in Restaurants beitragen und die reslutierenden Werte das Risiko von Angestellten (und Gästen) stark erhöhen.
Resumo:
Abstract
Resumo:
Audit report on the Iowa Water Pollution Control Works Financing Program (Clean Water Program) and the Iowa Drinking Water Facilities Financing Program (Drinking Water Program), joint programs of the Iowa Finance Authority and the Iowa Department of Natural Resources, for the year ended June 30, 2005
Resumo:
Audit report on the Iowa Water Pollution Control Works Financing Program (Clean Water Program) and the Iowa Drinking Water Facilities Financing Program (Drinking Water Program), joint programs of the Iowa Finance Authority and the Iowa Department of Natural Resources, for the year ended June 30, 2004