994 resultados para instrumentation: miscellaneous


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electron and x-ray diffraction experiments on the metlt-spun Al100−x Fe x (x=14, 18, 25) alloys are carried out. It is observed that all the melt-spun alloys possessing the quasi-crystalline phases have icosahedral point-group symmetry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bulk SixTe100-x (10 less-than-or-equals, slant x less-than-or-equals, slant 28) glasses have been prepared by the melt quenching technique. The crystallization of these glasses has been studied by using differential scanning calorimetry. The composition dependence of the glass transition temperature Tg, the recrystallization temperature Tcr and the melting temperature Tm show an unusual behaviour at the composition x congruent with 20. The glasses with 10 less-than-or-equals, slant x less-than-or-equals, slant 20 undergo double glass transition and double stage crystallization phenomena. On the other hand, glasses with 22 less-than-or-equals, slant x less-than-or-equals, slant 28 exhibit eutectic crystallization. The phases at different stages of crystallization have been identified by using X-ray diffraction techniques. The unusual behaviour at x congruent with 20 can be explained on the basis of the changes in the network topologies of IV-VI chalcogenide glasses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study of Bi-doped amorphous (Ge42S58)100−xBix and Ge20S80−xBix has been carried out by differential thermal analysis (DTA) and X-ray diffraction methods so as to elucidate the impurity-induced modifications in the semiconductors. Thermal analysis reveals the presence of complex structural units in the modified material. An interesting feature of this study is the existence of a double glass transition in Ge20S80−xBix, which is reported for the first time in this system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The conformations of Boc-l-Phe-(AiB)3-OH (1) and Boc-l-Phe-(Aib)3-OMe (2) which correspond to the amino terminal sequence of the emerimicins and antiamoebins have been studied in solution using 270 MHz 1H n.m.r. In dimethyl sulphoxide solution both peptides show the presence of two strongly solvent shielded Aib NH groups, consistent with a consecutive β-turn conformation, involving the Aib(3) and Aib(4) NH groups in intramolecular 4 → I hydrogen bonds. This folded conformation is maintained for 2 in chloroform solution. Nuclear Overhauser effect studies provide evidence for a Type II Phe-Aib β-turn. An X-ray diffraction study of Boc-(d,l)-Phe-(Aib)3-OH establishes a single type III(III′) β-turn conformation with Aib(2)-Aib(3) as the corner residues. A single intramolecular 4 → I hydrogen bond between Phe(I) CO and Aib(4) NH groups is observed in the crystal. The solution conformation may incorporate a consecutive type II-III′ structure for the Phe(1)-Aib(2)-Aib(3) segment, with the initial type II β-turn being destabilized by intermolecular interactions in the solid state.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the architecture and the VHDL design of an integer 2-D DCT used in the H.264/AVC. The 2-D DCT computation is performed by exploiting it’s orthogonality and separability property. The symmetry of the forward and inverse transform is used in this implementation. To reduce the computation overhead for the addition, subtraction and multiplication operations, we analyze the suitability of carry-free position independent residue number system (RNS) for the implementation of 2-D DCT. The implementation has been carried out in VHDL for Altera FPGA. We used the negative number representation in RNS, bit width analysis of the transforms and dedicated registers present in the Logic element of the FPGA to optimize the area. The complexity and efficiency analysis show that the proposed architecture could provide higher through-put.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Artifacts in the form of cross peaks have been observed along two- and three-quantum diagonals in single-quantum two-dimensional correlated (COSY) spectra of several peptides and oligonucleotides. These have been identified as due to the presence of a non-equilibrium state of kind I (a state describable by populations which differ from equilibrium) of strongly coupled spins carried over from one experiment to the next in the COSY algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of pressure on the electrical resistivity of bulk Si20Te80 glass is reported. Results of calorimetric, X-ray and transmission electron microscopy investigations at different stages of crystallization of bulk Si20Te80 glass are also presented. A pressure induced glass-to-crystal transition occurs at a pressure of 7 GPa. Pressure and temperature dependence of the electrical resistivity of Si20Te80 glass show the observed transition is a pressure induced glassy semiconductor to crystalline metal transition. The glass also exhibits a double Tg effect and double stage crystallization, under heating. The differences between the temperature induced crystallization (primary crystallization) and pressure induced congruent crystallization are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pressure and temperature dependence of the electrical resistivity of bulk glassy Ge20Te80 is reported. The effect of annealing is also studied. The glass undergoes a polymorphous or congruent crystallization under high pressures. The high pressure phase is found to have fcc structure with Image . Under thermal treatment the glass undergoes the double stage crystallization. The sample annealed at the first crystallization temperature shows a pressure induced semiconductor-to-metal transition at 4.0 GPa pressure and the crystalline Ge20Te80 samples show the transition at 7 GPa pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human exposures in transportation microenvironments are poorly represented by ambient stationary monitoring. A number of on-road studies using vehicle-based mobile monitoring have been conducted to address this. Most previous studies were conducted on urban roads in developed countries where the primary emission source was vehicles. Few studies have examined on-road pollution in developing countries in urban settings. Currently, no study has been conducted for roadways in rural environments where a substantial proportion of the population live. This study aimed to characterize on-road air quality on the East-West Highway (EWH) in Bhutan and identify its principal sources. We conducted six mobile measurements of PM10, particle number (PN) count and CO along the entire 570 km length of the EWH. We divided the EWH into five segments, R1-R5, taking the road length between two district towns as a single road segment. The pollutant concentrations varied widely along the different road segments, with the highest concentrations for R5 compared with other road segments (PM10 = 149 µg/m3, PN = 5.74 × 104 particles/cm-3, CO = 0.19 ppm), which is the final segment of the road to the capital. Apart from vehicle emissions, the dominant sources were road works, unpaved roads and roadside combustion activities. Overall, the highest contributions above the background levels were made by unpaved roads for PM10 (6 times background), and vehicle emissions for PN and CO (5 and 15 times background, respectively). Notwithstanding the differences in instrumentation used and particle size range measured, the current study showed lower PN concentrations compared with similar on-road studies. However, concentrations were still high enough that commuters, road maintenance workers and residents living along the EWH, were potentially exposed to elevated pollutant concentrations from combustion and non-combustion sources. Future studies should focus on assessing the dispersion patterns of roadway pollutants and defining the short- and long-term health impacts of exposure in Bhutan, as well as in other developing countries with similar characteristics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work explores the electrical properties of p-SnS/n-ITO heterojunction at different temperatures. The p-type SnS film was deposited on n-type ITO substrate using the thermal evaporation technique and its junction properties were studied using two probe method. The as-grown p-n junction exhibited weak rectifying behaviour with a low Saturation current of the order of similar to 10(-6) A. While increasing temperature, the saturation current of the junction is increased and however, its series resistance decreased. At all temperatures the junction exhibited three types of transport mechanisms depending on applied bias-voltage. At lower voltages the junction showed nearly ideal diode characteristics. The junction behaviour with respect to bias-voltage and temperature is discussed with the help of existing theories and energy band diagram.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of socket prostheses Currently, for individuals with limb loss, the conventional method of attaching a prosthetic limb relies on a socket that fits over the residual limb. However, there are a number of issues concerning the use of a socket (e.g., blisters, irritation, and discomfort) that result in dissatisfaction with socket prostheses, and these lead ultimately a significant decrease in quality of life. Bone-anchored prosthesis Alternatively, the concept of attaching artificial limbs directly to the skeletal system has been developed (bone anchored prostheses), as it alleviates many of the issues surrounding the conventional socket interface.Bone anchored prostheses rely on two critical components: the implant, and the percutaneous abutment or adapter, which forms the connection for the external prosthetic system (Figure 1). To date, an implant that screws into the long bone of the residual limb has been the most common intervention. However, more recently, press-fit implants have been introduced and their use is increasing. Several other devices are currently at various stages of development, particularly in Europe and the United States. Benefits of bone-anchored prostheses Several key studies have demonstrated that bone-anchored prostheses have major clinical benefits when compared to socket prostheses (e.g., quality of life, prosthetic use, body image, hip range of motion, sitting comfort, ease of donning and doffing, osseoperception (proprioception), walking ability) and acceptable safety, in terms of implant stability and infection. Additionally, this method of attachment allows amputees to participate in a wide range of daily activities for a substantially longer duration. Overall, the system has demonstrated a significant enhancement to quality of life. Challenges of direct skeletal attachment However, due to the direct skeletal attachment, serious injury and damage can occur through excessive loading events such as during a fall (e.g., component damage, peri-prosthetic fracture, hip dislocation, and femoral head fracture). These incidents are costly (e.g., replacement of components) and could require further surgical interventions. Currently, these risks are limiting the acceptance of bone-anchored technology and the substantial improvement to quality of life that this treatment offers. An in-depth investigation into these risks highlighted a clear need to re-design and improve the componentry in the system (Figure 2), to improve the overall safety during excessive loading events. Aim and purposes The ultimate aim of this doctoral research is to improve the loading safety of bone-anchored prostheses, to reduce the incidence of injury and damage through the design of load restricting components, enabling individuals fitted with the system to partake in everyday activities, with increased security and self-assurance. The safety component will be designed to release or ‘fail’ external to the limb, in a way that protects the internal bone-implant interface, thus removing the need for restorative surgery and potential damage to the bone. This requires detailed knowledge of the loads typically experienced by the limb and an understanding of potential overload situations that might occur. Hence, a comprehensive review of the loading literature surrounding bone anchored prostheses will be conducted as part of this project, with the potential for additional experimental studies of the loads during normal activities to fill in gaps in the literature. This information will be pivotal in determining the specifications for the properties of the safety component, and the bone-implant system. The project will follow the Stanford Biodesign process for the development of the safety component.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several orientation and tracking systems employed in parabolic-cylindrical concentrators for focusing the direct solar radiation on the absorber tubes are analyzed from the technical and economic points of view. Case one, where the incidence factor was a function of declination and hour angle, showed that the maximum variations of incident factor from morning to noon was 0.5 at zero angle of declination. Case two, where the incidence factor was a function of declination, hour angle and latitude, showed the maximum variation of the incidence factor to be 0.128, which occurred during noon at the latitude of 30 degrees, corresponding to a change of declination from 0 to 23.5 degrees. In case three, the incidence factor, a function of declination only, showed that the maximum variation of the incidence factor corresponding to the change in declination from 0 to 23.5 degree was 0.0758. It is concluded that system three is the most efficient from the technical and economic point of view.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To strive to improve the rehabilitation program of individuals with transfemoral amputation fitted with bone-anchored prosthesis based on data from direct measurements of the load applied on the residuum we first of all need to understand the load applied on the fixation. Therefore the load applied on the residuum was first directly measured during standardized activities of daily living such as straight line level walking, ascending and descending stairs and a ramp and walking around a circle. From measuring the load in standardized activities of daily living the load was also measured during different phases of the rehabilitation program such as during walking with walking aids and during load bearing exercises.[1-15] The rehabilitation program for individuals with a transfemoral amputation fitted with an OPRA implant relies on a combination of dynamic and static load bearing exercises.[16-20] This presentation will focus on the study of a set of experimental static load bearing exercises. [1] A group of eleven individuals with unilateral transfemoral amputation fitted with an OPRA implant participated in this study. The load on the implant during the static load bearing exercises was measured using a portable system including a commercial transducer embedded in a short pylon, a laptop and a customized software package. This apparatus was previously shown effective in a proof-of-concept study published by Prof. Frossard. [1-9] The analysis of the static load bearing exercises included an analysis of the reliability as well as the loading compliance. The analysis of the loading reliability showed a high reliability between the loading sessions indicating a correct repetition of the LBE by the participants. [1, 5] The analysis of the loading compliance showed a significant lack of axial compliance leading to a systematic underloading of the long axis of the implant during the proposed experimental static LBE.