999 resultados para X.500
Resumo:
BACKGROUND: One of the standard options in the treatment of stage IIIA/N2 non-small-cell lung cancer is neoadjuvant chemotherapy and surgery. We did a randomised trial to investigate whether the addition of neoadjuvant radiotherapy improves outcomes. METHODS: We enrolled patients in 23 centres in Switzerland, Germany and Serbia. Eligible patients had pathologically proven, stage IIIA/N2 non-small-cell lung cancer and were randomly assigned to treatment groups in a 1:1 ratio. Those in the chemoradiotherapy group received three cycles of neoadjuvant chemotherapy (100 mg/m(2) cisplatin and 85 mg/m(2) docetaxel) followed by radiotherapy with 44 Gy in 22 fractions over 3 weeks, and those in the control group received neoadjuvant chemotherapy alone. All patients were scheduled to undergo surgery. Randomisation was stratified by centre, mediastinal bulk (less than 5 cm vs 5 cm or more), and weight loss (5% or more vs less than 5% in the previous 6 months). The primary endpoint was event-free survival. Analyses were done by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00030771. FINDINGS: From 2001 to 2012, 232 patients were enrolled, of whom 117 were allocated to the chemoradiotherapy group and 115 to the chemotherapy group. Median event-free survival was similar in the two groups at 12·8 months (95% CI 9·7-22·9) in the chemoradiotherapy group and 11·6 months (8·4-15·2) in the chemotherapy group (p=0·67). Median overall survival was 37·1 months (95% CI 22·6-50·0) with radiotherapy, compared with 26·2 months (19·9-52·1) in the control group. Chemotherapy-related toxic effects were reported in most patients, but 91% of patients completed three cycles of chemotherapy. Radiotherapy-induced grade 3 dysphagia was seen in seven (7%) patients. Three patients died in the control group within 30 days after surgery. INTERPRETATION: Radiotherapy did not add any benefit to induction chemotherapy followed by surgery. We suggest that one definitive local treatment modality combined with neoadjuvant chemotherapy is adequate to treat resectable stage IIIA/N2 non-small-cell lung cancer. FUNDING: Swiss State Secretariat for Education, Research and Innovation (SERI), Swiss Cancer League, and Sanofi.
Resumo:
BACKGROUND: Primary ovarian insufficiency (POI) is defined as a primary ovarian defect characterized by absent menarche (primary amenorrhea), a decrease in the initial primordial follicle number, high follicle-stimulating hormone (FSH) levels and hypoestrogenism. Although the etiology of a majority of POI cases is not yet identified, several data suggest that POI has a strong genetic component. Conventional cytogenetic and molecular analyses have identified regions of the X chromosome that are associated with ovarian function, as well as POI candidate genes, such as FMR1 and DIAPH2. Here we describe a 10.5-year-old girl presenting with high FSH and luteinizing hormone (LH) levels, pathologic GH stimulation arginine and clonidine tests, short stature, pterygium, ovarian dysgenesis, hirsutism and POI. RESULTS: Cytogenetic analysis demonstrated a balanced reciprocal translocation between the q arms of chromosomes X and 1, with breakpoints falling in Xq21 and 1q41 bands. Molecular studies did not unravel any chromosome microdeletion/microduplication, and no XIST-mediated inactivation was found on the derivative chromosome 1. Interestingly, through immunofluorescence assays, we found that part of the Xq21q22 trait, translocated to chromosome 1q41, was late replicating and therefore possibly inactivated in 30 % metaphases both in lymphocytes and skin fibroblasts, in addition to a skewed 100 % inactivation of the normal X chromosome. These findings suggest that a dysregulation of gene expression might occur in this region. Two genes mapping to the Xq translocated region, namely DIAPH2 and FMR1, were found overexpressed if compared with controls. CONCLUSIONS: We report a case in which gonadal dysgenesis and POI are associated with over-expression of DIAPH2 gene and of FMR1 gene in wild type form. We hypothesize that this over-expression is possibly due to a phenomenon known as "chromosomal position effect", which accounts for gene expression variations depending on their localization within the nucleus. For the same effect a double mosaic inactivation of genes mapping to the Xq21-q22 region, demonstrated by immunofluorescence assays, may be the cause of a functional Xq partial monosomy leading to most Turner traits of the proband's phenotype.
Resumo:
Contrasting with birds and mammals, poikilothermic vertebrates often have homomorphic sex chromosomes, possibly resulting from high rates of sex-chromosome turnovers and/or occasional X-Y recombination. Strong support for the latter mechanism was provided by four species of European tree frogs, which inherited from a common ancestor (∼5 Ma) the same pair of homomorphic sex chromosomes (linkage group 1, LG1), harboring the candidate sex-determining gene Dmrt1. Here, we test sex linkage of LG1 across six additional species of the Eurasian Hyla radiation with divergence times ranging from 6 to 40 Ma. LG1 turns out to be sex linked in six of nine resolved cases. Mapping the patterns of sex linkage to the Hyla phylogeny reveals several transitions in sex-determination systems within the last 10 My, including one switch in heterogamety. Phylogenetic trees of DNA sequences along LG1 are consistent with occasional X-Y recombination in all species where LG1 is sex linked. These patterns argue against one of the main potential causes for turnovers, namely the accumulation of deleterious mutations on nonrecombining chromosomes. Sibship analyses show that LG1 recombination is strongly reduced in males from most species investigated, including some in which it is autosomal. Intrinsically low male recombination might facilitate the evolution of male heterogamety, and the presence of important genes from the sex-determination cascade might predispose LG1 to become a sex chromosome.
Resumo:
OBJETIVO: Reduzir a dose de radiação e aumentar a vida útil do tubo de raios X em exames de tomografia computadorizada. MATERIAIS E MÉTODOS: Foram avaliados exames de crânio, abdome superior e tórax. Foi verificado se a técnica utilizada poderia ser alterada, foram sugeridos novos protocolos, e feitas comparações de qualidade da imagem, dose de radiação e aquecimento do tubo de raios X. RESULTADOS: Uma redução no mAs pôde ser feita sem comprometer a qualidade do diagnóstico, proporcionando redução de até 20% na dose média dos exames de crânio em adultos e de até 45% em crianças com idade de 0 a 6 meses; pacientes com menos de 50 kg tiveram redução de aproximadamente 37% na dose média de radiação para os exames de abdome superior; para o exame de tórax de rotina a redução chegou a 54%. O aquecimento do tubo de raios X para os exames de crânio, abdome superior e tórax teve redução estimada em aproximadamente 13%, 23% e 41%, respectivamente. CONCLUSÃO: Uma alteração nos protocolos dos exames descritos acarretará diminuição significativa na dose de radiação e aumento na vida útil do tubo de raios X, sem comprometer o diagnóstico.
Resumo:
El terme alou indicava originàriament en el món germànic els béns hereditaris o de successió del patrimoni familiar, en oposició als adquirits per compra, aquests darrers designats amb la paraula comparata, segons la distinció establerta ja en les lleis sàlica, ripuària, alamannorum i baiwariorum. Trobem la mateixa contraposició en les Formulae Bignonianae i Lindenbrogianae. Com que els béns adquirits solien ser béns no lliures que es concedien en benefici, els béns alodials, per a evitar confusions, van designar, des de l"etapa carolíngia, la terra que no estava en situació de dependència, la terra lliure. El vocable alou és, sens dubte, herència del germànic.
Resumo:
We present the results of stereoscopic observations of the satellite galaxy Segue 1 with the MAGIC Telescopes, carried out between 2011 and 2013. With almost 160 hours of good-quality data, this is the deepest observational campaign on any dwarf galaxy performed so far in the very high energy range of the electromagnetic spectrum. We search this large data sample for signals of dark matter particles in the mass range between 100 GeV and 20 TeV. For this we use the full likelihood analysis method, which provides optimal sensitivity to characteristic gamma-ray spectral features, like those expected from dark matter annihilation or decay. In particular, we focus our search on gamma-rays produced from different final state Standard Model particles, annihilation with internal bremsstrahlung, monochromatic lines and box-shaped signals. Our results represent the most stringent constraints to the annihilation cross-section or decay lifetime obtained from observations of satellite galaxies, for masses above few hundred GeV. In particular, our strongest limit (95% confidence level) corresponds to a ~ 500 GeV dark matter particle annihilating into τ+τ−, and is of order langleσannvrangle simeq 1.2 × 10−24 cm3 s−1 a factor ~ 40 above the langleσannvrangle simeq thermal value.
Resumo:
El objetivo del presente trabajo es evaluar las propiedades mecánicas, así como los diferentes mecanismos de fractura activados mediante ensayos de indentación instrumentada, de electrolitos basados en circona estabilizada con itria ("yttria stabilized zirconia",YSZ) y ceria dopada con gadolinia ("gadolinia doped ceria", GDC), para pilas de combustible de óxido sólido, SOFCs. Ambos materiales, con un espesor final de 200 ¿m, se conformaron mediante prensado uniaxial a 500 MPa y se sinterizaron a 1400ºC. Propiedades mecánicas tales como la dureza (H) y el módulo de Young (E) han sido estudiadas a diferentes profundidades de penetración utilizando el algoritmo de Oliver y Pharr.
Resumo:
OBJETIVO: Desenvolver uma câmara de ionização de placas paralelas de dupla face para determinação de kerma no ar e taxa de kerma no ar em campos de radiação-X utilizados em radiografia convencional e mamografia. MATERIAIS E MÉTODOS: A câmara desenvolvida tem janelas de entrada de poliéster aluminizado, elétrodos internos e anéis de guarda de alumínio em uma face (face A) e de grafite na outra (face G). Neste trabalho foram testadas as características operacionais de linearidade, dependência angular e energética de resposta. RESULTADOS: A linearidade de resposta foi de 0,86% para a face A e de 0,92% para a face G. Para ângulos de incidência da radiação de 0° a ± 5°, a variação da resposta relativa foi menor que 0,8% para ambas as faces da câmara. A dependência energética de resposta foi de 0,8% para a face A nas qualidades de raios-X para diagnóstico convencional e de 2,4% para a face G da câmara nas qualidades de raios-X para mamografia. CONCLUSÃO: Esta câmara pode ser utilizada rotineiramente na determinação de kerma no ar e taxa de kerma no ar em feixes de raios-X utilizados em radiografia convencional e mamografia.
Resumo:
OBJETIVO: Este trabalho analisa as conseqüências da irradiação-X no desenvolvimento do sistema nervoso de fetos de ratos. MATERIAIS E MÉTODOS: O trabalho foi constituído de 10 Rattus norvegicus albinos, Wistar, fêmeas, grávidas, com idade de oito semanas. Cinco ratas fêmeas constituíram o grupo controle e outras cinco tiveram suas regiões abdominais expostas por 30 segundos a uma dose de 0,3 Gy proveniente de um aparelho odontológico Gnatus de 70 kV e 10 mA. No 17º dia gestacional, ambos os grupos foram submetidos a histerectomia. As seções selecionadas foram examinadas para análise cerebral comparativa entre os grupos. RESULTADOS: O exame clínico revelou não haver diferenças morfológicas entre os grupos controle e experimental e nenhum dos animais apresentou anormalidades grosseiras. Vinte e sete por cento dos animais do grupo experimental apresentaram hemorragia cerebral moderada e 73% apresentaram hemorragia severa e danos no tecido nervoso. Nenhum animal do grupo controle apresentou hemorragia cerebral ou danificações de tecido nervoso. CONCLUSÃO: Estas evidências demonstram que pequenas doses de radiação-X podem causar hemorragias cerebrais e, conseqüentemente, lesão tecidual nervosa.
Resumo:
OBJETIVO: Avaliar a coincidência entre o campo luminoso e o campo de radiação, e o alinhamento do feixe de radiação dos equipamentos de raios X médico no Estado da Paraíba, por meio de dois testes de controle de qualidade. MATERIAIS E MÉTODOS: Foram utilizados os dispositivos para os testes de tamanho de campo e de alinhamento, um chassi carregado, trena e nível de bolha. Os testes de exatidão do sistema de colimação e de alinhamento do raio central do feixe de raios X foram realizados durante as inspeções sanitárias em serviços de radiologia nos anos de 2008 e 2009. RESULTADOS: No ano de 2008, 121 equipamentos de raios X foram testados no Estado da Paraíba. No ano de 2009, passaram pelos testes 117 equipamentos. Deste universo, 86 foram selecionados para a comparação por terem sido avaliados tanto no ano de 2008 como em 2009, sendo observada uma melhoria de 18,60% (n = 16) nos resultados dos testes realizados de um ano para outro. CONCLUSÃO Conclusão: Pode-se concluir que o percentual de equipamentos apresentando problemas no seu desempenho sofreu uma diminuição entre 2008 e 2009, não sendo observado programa de garantia de qualidade em nenhum dos serviços de radiologia do Estado da Paraíba.
Resumo:
En este trabajo se estudia la preparació n y caracterizació n de las fases de los cristales mixtos de f órmula Li(NH4)1-xKxSO4. La caracterizacói n se ha efectuado por aná lisis té rmico con DSC y ATD, difracci ón de rayos-X sobre polvo cristalino con temperatura variable, difracci n de rayos-X sobre muestra monocristalina a temperatura variable a fin de determina su estructura cristalina y por espectroscop"a Raman a temperatura variable. Se han obtenido dos tipos de fases. Una soluci n s lida con 0.94 < x < 1 que presenta los mismos tipos estructurales que el LiKSO4, pero seg n el m todo de cristalizaci n pueden aparecer nuevas fases que no presenta el LiKSO4. El segundo tipo de compuesto tiene por f rmula Li(NH4)0.53K0.47SO4, el cual presenta una estructura hexagonal con par metro a » 3 aLiKSO4. Este compuesto tiene por encima de la temperatura ambiente una sola transici n a 463K.