969 resultados para X-rays: general
Resumo:
The cytogenetic study of 182 river buffalo (Bubalus bubalis L., 2n=50) of Murrah, Mediterranean and Jaffarabadi breeds, from the State of São Paulo, was carried out to characterize their chromosomes and to detect possible chromosomal abnormalities. The karyotypes were indistinguishable with conventional staining as well as with C and replication R banding techniques. In about 44% of the sample (8 males and 72 females), an X marker chromosome due to a fragile site was shown. The frequency of metaphases expressing the fragility site on the X was highly variable, from 2.86 to 41.03%. In females, the fragile site, rarely appeared on both X chromosomes. Most of the metaphases showed only 1 marker chromosome. In R-banded metaphases using 5-bromodeoxyuridine (BrdU) treatment, it corresponded in general to the late replicating X chromosome. No correlation between the X fragile site and altered phenotype was found. Structural and numerical chromosome rearrangements were ruled out in the present sample of buffalo. (C) 1998 by Elsevier B.V.
Resumo:
Objective To report the severe metabolic acidosis identified in a group of 11 healthy mules anaesthetized with halothane for castration.Study design Data generated from a prospective study.Animals Eleven mules aged 2.5-8 years, weighing 230-315 kg and 11 horses aged 1.5-3.5 years, weighing 315-480 kg.Methods Animals were anaesthetized for castration as part of an electroencephalographic study. Preanaesthetic medication was acepromazine (0.03 mg kg(-1)) administered through a preplaced jugular venous catheter. Anaesthesia was induced 30-90 minutes later with intravenous thiopental (10 mg kg(-1)). After orotracheal intubation, anaesthesia was maintained with halothane vaporised in oxygen. The animals' lungs were ventilated to maintain the end-tidal CO(2) concentration between 3.9 and 4.5 kPa (29-34 mmHg). Anaesthetic monitoring included invasive blood pressure measurement via the auricular artery (mules) and submandibular branch of the facial artery (horses). Arterial blood gas samples were drawn from these catheters at three time points during surgery and pH, PaCO(2), base excess (ecf) and HCO(3)(-) were measured. Values were compared between groups using a Mann-Whitney test. p was taken as <0.05. Results are reported as median (range).Results PaCO(2) did not differ between groups but pH was significantly lower in mules [7.178 (7.00-7.29)] compared to horses [7.367 (7.24-7.43)] (p = 0.0002). HCO(3)(-) values were significantly lower in the mules [16.6 (13.0-22.3) mM] compared to horses [23.7 (20.9-23.7) mM] (p = 0.0001), whilst base excess (ecf) was significantly more negative in the mules [-11.4 (-1.27 to -16) mM] compared to horses [-1.3 (-5.8 to +2.4) mM] (p = 0.0004).Conclusion and clinical relevance This study demonstrated severe metabolic acidosis in healthy mules, which may have prompted intervention with drug therapies in a clinical arena. It is probable that the acidosis existed prior to anaesthesia and caused by diet, but other possible causes are considered.
Resumo:
In this work, motivated by non-ideal mechanical systems, we investigate the following O.D.E. ẋ = f (x) + εg (x, t) + ε2g (x, t, ε), where x ∈ Ω ⊂ ℝn, g, g are T periodic functions of t and there is a 0 ∈ Ω such that f (a 0) = 0 and f′ (a0) is a nilpotent matrix. When n = 3 and f (x) = (0, q (x 3) , 0) we get results on existence and stability of periodic orbits. We apply these results in a non ideal mechanical system: the Centrifugal Vibrator. We make a stability analysis of this dynamical system and get a characterization of the Sommerfeld Effect as a bifurcation of periodic orbits. © 2007 Birkhäuser Verlag, Basel.
Resumo:
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function - MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device. © 2009 American Institute of Physics.
Resumo:
The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS experiment uses self-triggering arrays of drift tubes in the barrel muon trigger to perform the identification of the correct bunch crossing. The identification is unique only if the trigger chain is correctly synchronized. In this paper, the synchronization performed during an extended cosmic ray run is described and the results are reported. The random arrival time of cosmic ray muons allowed several synchronization aspects to be studied and a simple method for the fine synchronization of the Drift Tube Local Trigger at LHC to be developed. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS High-Level Trigger (HLT) is responsible for ensuring that data samples with potentially interesting events are recorded with high efficiency and good quality. This paper gives an overview of the HLT and focuses on its commissioning using cosmic rays. The selection of triggers that were deployed is presented and the online grouping of triggered events into streams and primary datasets is discussed. Tools for online and offline data quality monitoring for the HLT are described, and the operational performance of the muon HLT algorithms is reviewed. The average time taken for the HLT selection and its dependence on detector and operating conditions are presented. The HLT performed reliably and helped provide a large dataset. This dataset has proven to be invaluable for understanding the performance of the trigger and the CMS experiment as a whole. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12 000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Com o objetivo de verificar a existência da interação genótipo x ambiente, sob a forma de heterogeneidade de variâncias para a produção de leite na espécie bubalina e o seu impacto na avaliação genética dos animais, utilizando a inferência Bayesiana por meio de Amostrador de Gibbs, foram utilizados 5.484 registros de produção de leite referentes à produções de 2.994 búfalas predominantemente Murrah, filhas de 150 reprodutores, acasalados com 1130 matrizes, cujos partos ocorreram entre os anos de 1974 e 2004. Os registros foram provenientes do Programa de Melhoramento Genético dos Bubalinos (PROMEBUL) com a adição de registros provenientes do rebanho da EMBRAPA Amazônia Oriental -EAO, localizada em Belém, Pará. Foram estabelecidas classes de rebanho-ano de parto e de acordo com o desvio padrão de cada classe, os registros de produção de leite foram classificados em classes de alto e baixo desvio-padrão fenotípico. Posteriormente, os dados foram analisados desconsiderando e considerando as classes de desvio-padrão. O modelo utilizado empregou os efeitos fixos referentes às classes de rebanho-ano, mês de parto e covariáveis idade da fêmea ao parto e duração da lactação, além do efeito aleatório de animal, ambiente permanente e ambiente temporário. Para os efeitos fixos, foi assumido distribuição à priori uniforme e para os componentes de (co)variâncias foram assumidas distribuições priori qui-quadrado inversa e Wishart invertida. As médias observadas e desvio-padrão para produção de leite nas classes de alto e baixo desvio-padrão e em análise geral, foram iguais a 1870,21±758,78, 1900,50±587,76 e 1885,48±677,98, respectivamente. As médias posteriores para os componentes de variâncias foram maiores na classe de alto desvio-padrão. A herdabilidade obtida na classe de alto desvio-padrão foi próxima do valor observado na análise geral e inferior ao valor encontrado na classe de baixo desvio-padrão fenotípico. A correlação genética para produção de leite entre as classes de desvio-padrão foi igual a 0,58. As correlações de Spearman entre os valores genéticos para a produção de leite obtidos em análise geral com os valores obtidos nas classes de alto e baixo desvio padrão foram iguais a 0,94 e 0,93, respectivamente, para todos os reprodutores. Para uma amostra dos 10 melhores reprodutores, as mesmas correlações foram iguais a 0,94 e 0,47, respectivamente. Tais resultados revelam presença de heterogeneidade de variâncias entre rebanhos e esta heterogeneidade de variâncias é resultante de fatores ambientais, que podem levar a uma classificação errônea dos melhores reprodutores geneticamente para a produção leite.