989 resultados para Ventricular Function


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various differential cross-sections are measured in top-quark pair (tt¯) events produced in proton--proton collisions at a centre-of-mass energy of s√=7 TeV at the LHC with the ATLAS detector. These differential cross-sections are presented in a data set corresponding to an integrated luminosity of 4.6 fb−1. The differential cross-sections are presented in terms of kinematic variables of a top-quark proxy referred to as the pseudo-top-quark whose dependence on theoretical models is minimal. The pseudo-top-quark can be defined in terms of either reconstructed detector objects or stable particles in an analogous way. The measurements are performed on tt¯ events in the lepton+jets channel, requiring exactly one charged lepton and at least four jets with at least two of them tagged as originating from a b-quark. The hadronic and leptonic pseudo-top-quarks are defined via the leptonic or hadronic decay mode of the W boson produced by the top-quark decay in events with a single charged lepton.The cross-section is measured as a function of the transverse momentum and rapidity of both the hadronic and leptonic pseudo-top-quark as well as the transverse momentum, rapidity and invariant mass of the pseudo-top-quark pair system. The measurements are corrected for detector effects and are presented within a kinematic range that closely matches the detector acceptance. Differential cross-section measurements of the pseudo-top-quark variables are compared with several Monte Carlo models that implement next-to-leading order or leading-order multi-leg matrix-element calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tt¯ production cross-section dependence on jet multiplicity and jet transverse momentum is reported for proton--proton collisions at a centre-of-mass energy of 7 TeV in the single-lepton channel. The data were collected with the ATLAS detector at the CERN Large Hadron Collider and comprise the full 2011 data sample corresponding to an integrated luminosity of 4.6 fb−1. Differential cross-sections are presented as a function of the jet multiplicity for up to eight jets using jet transverse momentum thresholds of 25, 40, 60, and 80 GeV, and as a function of jet transverse momentum up to the fifth jet. The results are shown after background subtraction and corrections for all detector effects, within a kinematic range closely matched to the experimental acceptance. Several QCD-based Monte Carlo models are compared with the results. Sensitivity to the parton shower modelling is found at the higher jet multiplicities, at high transverse momentum of the leading jet and in the transverse momentum spectrum of the fifth leading jet. The MC@NLO+HERWIG MC is found to predict too few events at higher jet multiplicities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In longitudinal studies of disease, patients may experience several events through a follow-up period. In these studies, the sequentially ordered events are often of interest and lead to problems that have received much attention recently. Issues of interest include the estimation of bivariate survival, marginal distributions and the conditional distribution of gap times. In this work we consider the estimation of the survival function conditional to a previous event. Different nonparametric approaches will be considered for estimating these quantities, all based on the Kaplan-Meier estimator of the survival function. We explore the finite sample behavior of the estimators through simulations. The different methods proposed in this article are applied to a data set from a German Breast Cancer Study. The methods are used to obtain predictors for the conditional survival probabilities as well as to study the influence of recurrence in overall survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several suction–water-content (s-w) calibrations for the filter paper method (FPM) used for soil-suction measurement have been published. Most of the calibrations involve a bilinear function (i.e., two different equations) with an inflection point occurring at 60 kPafunction with a smooth transition between the high and low suctions based on a regression analysis of various previously published calibrations obtained for filter paper Whatman No. 42 (W42) is presented and discussed. The approach is applied herein to data obtained from three establish bilinear calibrations (six equations) for W42 filter paper to determine the two fitting parameters of the continuous function. An experimental evaluation of the new calibration show that the suctions estimated by the contact FPM test using the proposed function compare well with suctions measured by other laboratory techniques for two different soils for the suction range of 50 kPa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nutrient recycling in the forest is linked to the production and decomposition of litter, which are essential processes for forest maintenance, especially in regions of nutritionally poor soils. Human interventions in forest such as selecttive logging may have strong impacts on these processes. The objectives of this study were to estimate litterfall production and evaluate the influence of environmental factors (basal area of vegetation, plant density, canopy cover, and soil physicochemical properties) and anthropogenic factors (post-management age and exploited basal area) on this production, in areas of intact and exploited forest in southern Amazonia, located in the northern parts of Mato Grosso state. This study was conducted at five locations and the average annual production of litterfall was 10.6 Mg ha-1 year-1, higher than the values for the Amazon rainforest. There were differences in litterfall productions between study locations. Effects of historical logging intensity on litterfall production were not significant. Effects of basal area of vegetation and tree density on litterfall production were observed, highlighting the importance of local vegetation characteristics in litterfall production. This study demonstrated areas of transition between the Amazonia-Cerrado tend to have a higher litterfall production than Cerrado and Amazonia regions, and this information is important for a better understanding of the dynamics of nutrient and carbon cycling in these transition regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioquímica Aplicada – Biomedicina

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tantalum oxynitride thin films were produced by magnetron sputtering. The films were deposited usinga pure Ta target and a working atmosphere with a constant N2/O2ratio. The choice of this constant ratiolimits the study concerning the influence of each reactive gas, but allows a deeper understanding of theaspects related to the affinity of Ta to the non-metallic elements and it is economically advantageous.This work begins by analysing the data obtained directly from the film deposition stage, followed bythe analysis of the morphology, composition and structure. For a better understanding regarding theinfluence of the deposition parameters, the analyses are presented by using the following criterion: thefilms were divided into two sets, one of them produced with grounded substrate holder and the otherwith a polarization of −50 V. Each one of these sets was produced with different partial pressure of thereactive gases P(N2+ O2). All the films exhibited a O/N ratio higher than the N/O ratio in the depositionchamber atmosphere. In the case of the films produced with grounded substrate holder, a strong increaseof the O content is observed, associated to the strong decrease of the N content, when P(N2+ O2) is higherthan 0.13 Pa. The higher Ta affinity for O strongly influences the structural evolution of the films. Grazingincidence X-ray diffraction showed that the lower partial pressure films were crystalline, while X-rayreflectivity studies found out that the density of the films depended on the deposition conditions: thehigher the gas pressure, the lower the density. Firstly, a dominant -Ta structure is observed, for lowP(N2+ O2); secondly a fcc-Ta(N,O) structure, for intermediate P(N2+ O2); thirdly, the films are amorphousfor the highest partial pressures. The comparison of the characteristics of both sets of produced TaNxOyfilms are explained, with detail, in the text.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the relationship of goblet cell density (GCD) with tear function and ocular surface physiology. Methods: This was a cross-sectional study conducted in 35 asymptomatic subjects with mean age 23.8±3.6 years. Tear film assessment, conjunctiva and cornea examination were done in each subject. Conjunctival impression cytology was performed by applying Nitrocellulose Millipore MFTM-Membrane filter over the superior bulbar conjunctiva. The filter paper was than fixed with 96% ethanol and stained with Periodic Acid Schiff, Hematoxylin and Eosin. GCD was determined by optical microscopy. Relation between GCD and Schirmer score, tear break-up time (TBUT), bulbar redness, limbal redness and corneal staining was determined. Results: The mean GCD was 151±122 cells/mm2. GCD was found higher in eyes with higher Schirmer score but it was not significant (p = 0.75). There was a significant relationship ofGCDwith TBUT (p = 0.042). GCD was not correlated with bulbar redness (p = 0.126), and limbal redness (p = 0.054) as well as corneal staining (p = 0.079). No relationship of GCD with age and gender of the subjects (p > 0.05) was observed. Conclusion: GCD was found correlated with TBUT but no significant correlation was found with the aqueous portion of the tear, limbal as well as bulbar redness and corneal staining.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar se o enalaprilato, droga inibidora da enzima de conversão da angiotensina I, previne a hipertrofia ventricular esquerda (HVE) induzida pelo isoproterenol. MÉTODOS: Foram divididos em 4 grupos, 72 ratos Wistar-EPM: CON controle; ENA, tratados com enalaprilato (1mg/kg via subcutânea (sc) por 8 dias); ISO, tratados com isoproterenol (0,3mg/kg via sc/8 dias) e ENA+ISO, tratados simultaneamente com ambas as drogas. Em 10 animais de cada grupo foram determinadas a freqüência cardíaca (FC) e a pressão arterial (PA) e verificado o peso de ventrículo esquerdo (VE). Em 8 animais de cada grupo, fragmento do VE foi corado com hematoxilina-eosina e picro-sírius e preparado para estudo morfométrico e ultra-estrutural, respectivamente, com microscópio de luz e eletrônico. RESULTADOS: Nos grupos estudados (CON, ENA, ISO e ISO+ENA) não ocorreram variações na PA. Os grupos ISO e ISO+ENA exibiram aumentos significantes na FC. O grupo ISO apresentou aumento significativo do peso do VE (PU= 0,821g e PS= 0,204g), quando comparado ao grupo CON. O grupo ENA não exibiu modificação de peso do VE quando comparado ao grupo CON (PU= 0,590g e PS= 0,139g). No grupo ENA+ISO (PU= 0,737g e PS= 0,177g) constatou-se diferença de peso ao ser comparado aos grupos ISO e CON. A análise morfométrica e ultra-estrutural mostraram que o ISO induziu hipertrofia dos cardiomiócitos e aumento do tecido conjuntivo com depósito de fibras colágenas do tipo I. O enalaprilato associado com isoproterenol atenuou importantemente aquela manifestação. CONCLUSÃO: O enalaprilato inibiu a ação do isoproterenol sobre os cardiomiócitos, evitando parcialmente, na dose utilizada, a HVE e diminuindo também a quantidade de fibras colágenas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinar as alterações de atividade da enzima conversora de angiotensina (ECA) no coração com infarto do miocárdio (IM) e comparar os efeitos do captopril e losartan em parâmetros morfológicos e funcionais de ratos com IM. MÉTODOS: O IM foi produzido em ratos Wistar por ligadura de ramos da artéria coronária esquerda. Os controles (Con) foram submetidos a uma cirurgia fictícia. Animais com IM e Con foram tratados com captopril (30mg/kg/dia) ou losartan (15mg/kg/dia) e estudados 30 dias após, determinando-se a atividade da ECA nos ventrículos direito (VD) e esquerdo (VE), as alterações hemodinâmicas e as concentrações de hidroxiprolina (OH-Pro) e proteína total no VD e VE. RESULTADOS: A atividade da ECA aumentou no VD (+25%) e VE (+70%) após IM. A maior atividade foi observada na cicatriz fibrótica, onde atingiu cerca de 4,5 vezes a do músculo do VE que sobreviveu ao IM (420±68 vs 94±8nmoles/g/min; P<0,01). O IM determinou aumento da pressão diastólica final e hipertrofia do VD e VE. Captopril e losartan foram igualmente eficazes em atenuar a hipertrofia e o aumento da pré-carga. O captopril também atenuou o aumento de OH-Pro no VD e VE após IM. O IM reduziu a concentração de proteína principalmente no músculo de VE, efeito esse acentuado pelo captopril. CONCLUSÃO: A grande atividade da ECA na cicatriz deve produzir altas concentrações de angiotensina II (AII) no sangue que drena da cicatriz. Os efeitos dos inibidores da ECA seriam decorrentes, principalmente, da redução de geração local de AII, e não de aumento de cininas, uma vez que captopril e losartan exerceram efeitos similares no remodelamento pós-infarto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the impact that the distribution of emphysema has on clinical and functional severity in patients with COPD. Methods: The distribution of the emphysema was analyzed in COPD patients, who were classified according to a 5-point visual classification system of lung CT findings. We assessed the influence of emphysema distribution type on the clinical and functional presentation of COPD. We also evaluated hypoxemia after the six-minute walk test (6MWT) and determined the six-minute walk distance (6MWD). Results: Eighty-six patients were included. The mean age was 65.2 ± 12.2 years, 91.9% were male, and all but one were smokers (mean smoking history, 62.7 ± 38.4 pack-years). The emphysema distribution was categorized as obviously upper lung-predominant (type 1), in 36.0% of the patients; slightly upper lung-predominant (type 2), in 25.6%; homogeneous between the upper and lower lung (type 3), in 16.3%; and slightly lower lung-predominant (type 4), in 22.1%. Type 2 emphysema distribution was associated with lower FEV1 , FVC, FEV1 /FVC ratio, and DLCO. In comparison with the type 1 patients, the type 4 patients were more likely to have an FEV1 < 65% of the predicted value (OR = 6.91, 95% CI: 1.43-33.45; p = 0.016), a 6MWD < 350 m (OR = 6.36, 95% CI: 1.26-32.18; p = 0.025), and post-6MWT hypoxemia (OR = 32.66, 95% CI: 3.26-326.84; p = 0.003). The type 3 patients had a higher RV/TLC ratio, although the difference was not significant. Conclusions: The severity of COPD appears to be greater in type 4 patients, and type 3 patients tend to have greater hyperinflation. The distribution of emphysema could have a major impact on functional parameters and should be considered in the evaluation of COPD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a participação do estado contrátil e do relaxamento miocárdico na disfunção do músculo cardíaco durante a transição hipertrofia-falência cardíaca em ratos espontaneamente hipertensos (SHR). MÉTODOS: Músculos papilares isolados do ventrículo esquerdo de SHR com insuficiência cardíaca (SHR-IC) e sem falência cardíaca (SHR) e de ratos normotensos controle Wistar-Kyoto (WKY) foram estudados em contrações isométrica e isotônica, em solução de Krebs-Henseleit (1,25 mM Ca2+, 28ºC). RESULTADOS: Os valores da tensão máxima desenvolvida (TD) e da velocidade máxima de encurtamento (Vmáx) foram menores nos SHR-IC e SHR, em relação aos WKY (p<0,05). TD e Vmáx foram semelhantes nos SHR-IC e SHR (p>0,05). A rigidez passiva do músculo aumentou significantemente nos SHR-IC (p<0,05 vs WKY e SHR); esta variável não diferiu entre WKY e SHR (p>0,05). CONCLUSÃO: Os dados obtidos mostram que a transição da fase de hipertrofia estável para insuficiência cardíaca nos ratos espontaneamente hipertensos está associada ao aumento da rigidez passiva do miocárdio e não à piora da função contrátil do músculo cardíaco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Saúde

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o perfil arritmogênico ventricular de pacientes com miocardiopatia dilatada e fração de ejeção diminuída. MÉTODOS: Estudo prospectivo em 40 pacientes com fração de ejeção média ao ecocardiograma de 32,5±2,1%, obtida pela análise do Holter de 24h, do balanço autonômico cardíaco, determinado por índices de variabilidade da freqüência cardíaca (rMSSD e pNN50), do eletrocardiograma (ECG) de alta resolução (ECGAR) e do grau de dispersão da repolarização ventricular determinado no ECG de superfície. Por regressão logística determinaram-se, a partir dos resultados, os preditores de risco para morte cardíaca e morte súbita. RESULTADOS: Observou-se na população envolvida uma elevada incidência de ectopias ventriculares isoladas, pareadas e de surtos não sustentados de taquicardia ventricular. Pela análise do balanço autonômico notou-se depressão da atividade vagal cardíaca em mais da metade dos pacientes, sendo que apenas 30% apresentaram ECGAR positivo. O grau de dispersão temporal da repolarização ventricular variou de 20 a 100ms. A presença de >30 extra-sístoles isoladas por hora e de taquicardia ventricular não sustentada ao Holter foram os preditores de risco com valores mais elevados para a morte cardíaca e morte súbita, com uma razão de risco respectiva de 1,9 e 3,2 (p= 0,01 e 0,000). CONCLUSÃO: Foram observadas importantes alterações no comportamento elétrico e autonômico cardíaco, constituindo-se fatores de risco para a ocorrência de eventos arrítmicos graves ou fatais.