950 resultados para Test results
Resumo:
Pós-graduação em Educação - FFC
Resumo:
Congenital toxoplasmosis is a serious public health case, for it causes irreversible damage to the embryo/fetus, which may cause its death. The identification and the care to pregnant women with suspect acute toxoplasmosis (IgM+) is performed in prenatal monitoring. This study aimed to measure the incidence and know the profile of positive pregnant women for toxoplasmosis in a Basic Health Unit (BHU) in Matão - SP, between the years 2011 to 2013. This is a retrospective descriptive study, from the medical records of pregnant women attended. The project was approved by the Municipal Departament of Health and BHU was chosen along the Municipal Epidemiological Surveillance. From 2011 to 2013, 189 women began prenatal care in the unit, an annual median of 71(±26.91), of which 17 (8.99%) were positive for the serological test indicative of acute phase (IgM+). The distribution over the trial period was: four cases in 2011, twelve cases in 2012 and one in 2013. Pregnant women IgM positive for toxoplasmosis attend by BHU were: age 24(±5.47) years; color: equally distributed among white, black and brown; as the number of pregnancies: multiparous (2±0.97), most of them with a cesarean delivery as obstetric history and possessed no other risk factors associated with pregnancy (94.12%); gave entrance at BHU with 13.65(±7.35) weeks of gestation and had a median of 5(±2.36) consultation on their prenatal care. The examination for toxoplasmosis was requested as recommended by the Health Ministry (HM) and the medication prescribed was Roxamicina® - spiramycin, as soon as the test results (IgM+) arrived. Of the 17 pregnant women, only 10 completed the pre-natal at BHU - attendance at the postpartum consult (58.8%). Of these, the deliveries were vaginal (55.55%), made preterm with 36.5 weeks of gestation at the Municipal Hospital. The babies were born alive (100%) with the weight of 2.68(±0.77) Kg and required special care hospital scope. From the ...
Resumo:
This paper focuses data from discussions done with teachers who work with the three early years of nine-years elementary chool, in two Municipal schools of São Paulo inland, in order to investigate the students’ literacy degree. Considering a test applied to students of three early years of those schools, this study deals with the literacy performance results of 153 children of third school year. It also relates data of this test with some aspects that have characterized the literacy teachers’ practices. Initially, it presents considerations about the literacy process in extent of nine-years elementary school and some implications for the teachers’ practices. Then, it emphasizes the test results of third year students, pointing out what skills were already developed by them in literacy process and what skills must be improved. Results show that those children are not literated. They demonstrate difficulties in the appropriation of reading and writing skills, even in the third school year. It suggests the teachers’ need to reorganize their practices in classroom and to revise students’ literacy process, allowing to every student the full appropriation of reading and writing.
Resumo:
Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.
Resumo:
Objective: this study aimed to analyze the in vitro effect of brushing on the color stability of ceramic brackets immersed in dye solutions. Materials and Methods: seven ceramic brackets of four commercial brands were tested: two monocrystalline and two polycrystalline. The parameters of color were obtained by spectrophotometer before and after 21 days of immersion of the brackets in coffee, red wine, Coca-Cola, black tea and artificial saliva. Another group of brackets of each brand were also immersed in the same solutions and for an equal time to the previous group, but with intervals of daily brushing performed by a toothbrushing machine (Mavtec). The data were evaluated by analysis of variance, multiple comparison tests for means and Student's t-test. Results: the mean color change of the brackets without brushing ranged from 0.46 to 7.61, while in the group with brushing these means ranged from 0.36 to 2.50. The staining still remained noticeable (change of color greater than 3.7) for all brackets when immersed in black tea. Conclusion: daily brushing helped significantly in the color stability of ceramic brackets, maintaining the color change to levels considered not visible to the human eye, except for the solution of black tea in which the staining remained relevant.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: The study of graft donor sites, whether from the anatomical, physiological or morphological point of view, has become a topic of current interest, due to the increasing number of patients needing facial bone reconstruction for various reasons. Purpose: In view of the need to constantly improve surgical techniques for autogenous bone graft harvesting, still considered the best choice for facial bone reconstruction, this paper describes an anatomical study on dry skulls in order to evaluate the average thickness of the parietal bone. Material and Methods: Measurements of this bone were taken with a goniometer, at four previously defined points, in the region that is often used as a donor site, in 49 dry skulls (98 parietal bones). The results were evaluated using the T test. Results: Thickness was measured at four predetermined points. The mean values (Point A = 4898mm, B = 4517mm, C = 6185mm, D = 4280mm) show that the bone can be even thinner than previously reported in the literature in other studies of the same nature. The largest bone thickness is in the medial and posterior region. Conclusion: A knowledge of these anatomical characteristics is helpful in preventing possible surgical complications, as well as making it safer for the surgeon to remove this graft and providing more information on whether or not to indicate this region as a bone graft donor site.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
ABSTRACT. Introduction: an in vitro model was used to measure the hydraulic conductance in human dentin discs treated with oxalic acid for 15, 30 or 60 s maintaining the occlusive effect and measuring 7 and 14 days after application. Methods: 45 dentin discs measuring 1 mm thick were obtained from human third molars which were free of caries and in no occlusion; the samples were obtained from patients aged 16 to 30 years. Discs were sorted out into three study groups (n = 15) depending on the time of application of a commercial solution of oxalate-based dentin desensitizer (DD) (BisBlock®) which contains ˂ 5% oxalic acid of 1.5-1.8 pH: in group A the agent was applied for 15 s, in group B it was applied for 30 s, and in group C for 60 s. The hydraulic conductance of each disc was calculated after acid etching, which corresponds to the maximum permeability of discs (100%) after immediate application of oxalic acid, as well as seven and fourteen days of storage in saline solution. The statistical analysis was done with ANOVA test and post-hoc Games-Howell test. Results: 35,46 ± 23.41% in Group A, 36.34 ± 15.88% in Group B and 24.99 ± 14.99% in Group C, showing that the use of DD for 15, 30 or 60 s decreased permeability in a statistically significant manner (p <0.05). Conclusions: DD was effective in reducing hydraulic conductance regardless of application time, but this reduction was temporary only, since after seven days permeability returns to values close to those of baseline.
Resumo:
The Portland cement has shown similar biological properties to calcium hydroxide, but its radiopacity is lower. Therefore, the addition of materials that minimize this deficiency should be considered. OBJECTIVE: To evaluate the apical sealing ability and pH of a white Portland cement added of several radiopacifying agents. MATERIAL AND METHODS: Forty bovine roots with incomplete apices were selected, and the foraminal openings were standardized to PM 720G bur. After the external root sealing, an apical intracanal barrier 10.0 mm thick was executed with the white Portland cement powder, pure or added of a radiopacifying agent (iodoform, zinc oxide or bismuth subnitrate), and distilled water (0.37 mL). The apical roots were immersed 24h in water in humid atmosphere, and after that they were immersed 24h in 2% Rhodamine B, under vacuum. In sequence, the roots were longitudinally sectioned, the root fragments were photographed, the images were digitalized and the apical infiltration was measured by the Image Tool program. The pH solutions were also evaluated, in 24h and 48h and 7 and 30 days. Data were submitted to Anova test. RESULTS: The zinc oxide solution has the lowest apical infiltration in relation to the other groups (p < 0.05). The pH behavior varied during the analysis, and in the period of 24h all groups showed the highest values (p < 0.05). CONCLUSION: The type of radiopacifying agent used interferes in the sealing ability of the apical barrier, and zinc oxide showed to be the most beneficial one. The pH varies according to the period of analysis, and the highest values were obtained in the first 24h (p < 0.05).
Resumo:
Background: The aim of this study was to determine the perception of smile esthetics among orthodontists and laypeople with respect to the presence of diastemas in the upper lateral incisor in the mesial, distal, and both surfaces using an oblique smile analysis. Methods: Two standardized oblique photos of pleasant smiles from two white women were selected. Images were digitally altered to create diastemas in the lateral incisor, in 0.5-mm increments, in the mesial, distal, or both surfaces. Final images were randomly assembled in a photo album, which was given to 120 judgesd60 orthodontists and 60 laypersons. Each rater was asked to evaluate the attractiveness of the images on a visual analog scale. The data collected were submitted to statistical analysis by the means of one-way ANOVA with the Tukey post hoc test and the unpaired Student’s t test. Results: The most attractive smile was the one without spacing, and the presence of diastemas was considered unattractive by both groups of raters, following a pattern: the greater and the more mesially located, the more unattractive was the smile. Conclusions: The results of this study suggest that diastemas in the upper lateral incisor area were considered unattractive, following a pattern: the greater and the more mesially located, the more unattractive was the smile.
Resumo:
The adhesiveness of six root canal sealers: Acroseal, Endo CPM, Epiphany, White MTA, Sealapex and Sealer 26 to dentin, was evaluated in a push-out test design. Methods: Twenty eight roots of freshly extracted teeth were gauged with a size 5 Largo drill. With a cutting machine slices of 2 mm were prepared, rinsed with 5.25% NaOCl and a final rinse with 17% EDTA, dried and filled with one of the sealers. After setting their bond strength was measured in a mechanical testing machine. The data were statistically analyzed by using a One Way ANOVA and post hoc Tukey test. Results: The mean and standard deviation from values of bond strength was: Sealapex 2.2±0.4; Endo CPM 3.8±1.3; White MTA 6.0±1.4; Epiphany 10.9±2.6; Sealer 26 12.3±2.3; and Acroseal 12.2±1.4. Acroseal, Sealer 26 and Epiphany presented a significantly (P<0.01) greater bond strength compared with the other sealers. Also White MTA showed higher adhesiveness compared with Endo CPM and Sealapex (P<0.01). Conclusion: The bond strength between endodontic sealers and root dentin was maximal when Acroseal, Sealer 26 and Epiphany were used; Sealapex e Endo CPM, in turn, presented the lowest bond strength mean values.
Resumo:
Pós-graduação em Genética - IBILCE
Resumo:
Pós-graduação em Saúde Coletiva - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)